PILOT WASH 

 
 

PR-2302  

 
 
 
 
 
 
 

This product manual contains important information about the safe installation and 
use of this projector. Please read and follow these instructions carefully and keep this 
manual in a safe place for future reference. 

 
 
 
 

PEARL RIVER LIGHT & ACOUSTICS INDUSTRIAL LTD. 

Yingbin Road, Dashi Panyu, Guangzhou, 511430 China 

http://www.pr-lighting.com

     

[email protected]

   

Summary of Contents for PR-2302

Page 1: ... installation and use of this projector Please read and follow these instructions carefully and keep this manual in a safe place for future reference PEARL RIVER LIGHT ACOUSTICS INDUSTRIAL LTD Yingbin Road Dashi Panyu Guangzhou 511430 China http www pr lighting com info pr lighting com ...

Page 2: ...ge caused by improper use will not be assumed by the manufacturer and or dealer ACCESSORIES THESE ITEMS ARE PACKED TOGETHER WITH THE PROJECTOR Mounting Bracket 2 Pieces M8x25 bolt for mounting brackets 4 Pieces Power cord 1 Piece XLR plug 1 Piece XLR socket 1 Piece Safety cord 1 Piece This manual 1 Piece INTRODUCTION Thank you for purchasing the product PILOT WASH PR 2302 This product manual conta...

Page 3: ...frequency of power supply match the power requirements of the projector It is essential that each projector is correctly earthed and that electrical installation conforms to all relevant standards Do not connect this device to any dimmer pack Make sure that the power cable is never crimped or damaged by sharp edges Never let the power cable come into contact with other cables Only handle the power...

Page 4: ...ing a lamp you must let the old lamp cool sufficiently before opening the lamp access hatch Insert an MSD 250W lamp in the lamp holder Close the access hatch carefully and re tighten the 3 access screws LAMP ACCESS SCREW LAMP ACCESS HATCH LAMP ADJUSTMENT ACCESS SCREW ACCESS SCREW LAMP ADJUSTMENT LAMP ADJUSTMENT Adjust lamp position by turning screws A B and C A B C ONLY USE REPLACEMENT LAMP TYPE M...

Page 5: ...of the connections touch the body of the plug or each other The body of the plug is not connected in any way The PILOT WASH accepts digital control signals in standard DMX512 1990 format Connect the controller s output to the first fixture s input and connect the first fixture s output to the second fixture s input The rest may be deduced by analogy Eventually connect the last fixture s output to ...

Page 6: ...atic programme 2 enable N Automatic programmes 1 or 2 5 Y Master Slave operation of programmes 1 or 2 Y 16bit Pan Tilt movement resolution enable 6 N 16bit Pan Tilt movement resolution disable 7 Reserved 8 Reserved Once you have selected the desired operation code press the key UP or DOWN to select y means ON or no means OFF N NO Y YES Press the key ENTER to save the selected function and configur...

Page 7: ...t on this channel 1 stays in the range from 5 to 7 for more than 5 seconds the projector will start a reset sequence Remote Requested Reset The electronics are re started and all motors moved to their home positions exactly as they do when the power is first switched on but the lamp is not switched off in this sequence although the beam will be blacked out The channels 9 and 10 are only available ...

Page 8: ... fans should be cleaned every 15 days The lens and dichroic colour filters should also be regularly cleaned to maintain an optimum light output Do NOT use any type of solvent on dichroic colour filters Cleaning frequency depends on the environment in which the fixture operates damp smoke or particularly dirty surroundings can cause greater accumulation of dirt on the unit s optics A soft cloth and...

Page 9: ...ROL DMX 512 8 channels plus 2 for High Resolution Pan and Tilt Stand Alone Automatic mode and Master Slave operation FOCUS Manual adjustment of Fresnel lens SHUTTER STROBE 2 Blade shutter for linear dimming from 0 to 100 Also provides a strobe effect with speed variable from 1 7 F P S and blackout EFFECTS Softened or more defined beam HEAD MOVEMENT Pan 370º Tilt 265º BEAM ANGLE 16º MOTORS 9 Steppe...

Page 10: ...4V LOWER FAN UPPER FAN 2 UPPER FAN 1 9 CODES COLOURS 1 2 3 4 5 6 7 1 RED YELLOW ORANGE BROWN BLACK GREEN BLUE 2 3 4 5 6 7 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 4 1 2 6 BLACK RED DISPLAY PCB A2 A3 C2 A5 A6 A7 B2 AC B3 B4 B5 B6 B7 B8 B9 B 10 B 11 B 12 B 13 A9 A10 A8 DMX512 A1 B1 D F6 3A 250V L A4 1 2 3 C1 C3 16 PIN MAIN I C 60µF AC 370V 20V 50W THERMOSTAT 1 TRANSFORMER F4A 250V FUSE 1 N ...

Page 11: ...30040052 23HS0015L Ф6 35x21 A1 A7 IC 170050010 DRIVER CHIPS A8 IC 170110004 DRIVER CHIP A9 IC 170050001 ARITHMETIC AMPLIFIER CHIP A10 IC 170110004 DRIVER CHIP B1 IC 170040014 TTL LOGICAL CHIP B2 B7 IC 170170037 D A REVERSION CHIP B8 IC 170040014 TTL LOGICAL CHIP B9 B11 IC 170170037 D A REVERSION CHIP B12 B13 IC 170040014 TTL LOGICAL CHIP C1 IC 170170039 STABLE VOLTAGE CHIP C2 IC 170170012 BUS CHIP...