4512V100-UK 11

PR Process Supervisor - PPS app

The PR electronics ‘PR Process Supervisor’ - PPS - app enables remote data logging, programming and error diagnostics of PR 
4000/9000 devices mounted with the 4512 Bluetooth communication enabler.
The app shows live data directly from a smart device. It is designed for technical and maintenance staff as well as plant 
operators. All that is required to get started is to download the free app, and you have a user friendly interface for monitoring 
and programming of installed PR devices.

App download

If you have already downloaded the PR electronics PPS app from either the Apple App store (IOS) or Google Play (Android), 
check for updates that will add the Bluetooth communication options.

2

If you will be downloading the PR electronics PPS app for the first time, follow the instructions for IOS below. The Android 
download process will be similar.

2  Please consult app release notes for latest status of supported devices.

Go to the App store or 
scan the QR code  
(the code works for 
both IOS and Android).

Search for ”PR electronics PPS”, 
and install the free application.

Tap the newly created PPS icon.

Summary of Contents for 4512

Page 1: ...DE SMARTER ZONE 2 Zone 2 ZONE 2 DIV 2 Product Manual 4512 Bluetooth communication enabler TEMPERATURE I S INTERFACES COMMUNICATION INTERFACES MULTIFUNCTIONAL ISOLATION DISPLAY No 4512V100 UK From serial no 191003001 ...

Page 2: ...nication interfaces that can access your PR installed base of products All the interfaces are detachable have a built in display for readout of process values and diagnostics and can be configured via push buttons Product specific functionality includes communication via Modbus and Bluetooth and remote access using our PR Process Supervisor PPS application available for iOS and Android Our display...

Page 3: ... 6 4512 configuration operating the function keys 8 4512 settings routing diagram 9 PR Process Supervisor PPS app 10 App download 10 Connection and configuration 11 Pairing options 12 Time adjustment 12 Process simulation 12 Data logging set up 12 Analysis of logged data event logging and export 13 PReset software 14 Time adjustment 14 Detailed analysis of logged data 14 Data logging 16 Event log ...

Page 4: ...e coin cell battery Do not attempt to open the back cover or remove the battery as you may damage the device Safety instructions Receipt and unpacking Unpack the device without damaging it and check whether the device type corresponds to the one ordered Environment The device is manufactured for indoor use Avoid direct sunlight dust high temperatures mechanical vibrations and shock as well as rain...

Page 5: ... be observed FM installation in Zone 2 Div 2 FM US CL I Div 2 Gp A B C D T5 CL I Zn 2 Gp IIC T5 FM CA CL I Div 2 Gp A B C D T5 For safe Ex installation the following must be observed The device must be installed by qualified personnel who are familiar with the national and international laws directives and standards that apply to this area CAUTION To prevent injury read the manual before use WARNI...

Page 6: ...S is compatible with iOS and Android devices The PR 4512 automatically detects the device settings on the connected PR 4000 and 9000 device An internal battery energizes the 4512 real time clock for at least 2 years should the 4512 remain de energized Typical data logging capacity is more than 30 days at 1 second intervals Easy to read dot matrix LCD display Fast pairing or safe pairing via two fa...

Page 7: ... dot matrix LCD display Line 1 can e g show the scaled process value Line 2 can e g show the selected engineering unit Line 3 can e g show the analog output or TAG no Line 4 shows status for communication and e g signal trending Icons illustrate left to right Relay s status Input signal trend up down Display communication to host Logdata present steady or logging in progress blinking ...

Page 8: ...dio Class 2 Data logging Memory 100 MB Capacity 2 75 million data points1 Data retention without power 10 years Observed authority requirements Directives EMC 2014 30 EU RED 2014 53 EU ATEX 2014 34 EU RoHS 2011 65 EU Standards UL Standard for Safety UL 61010 1 Bluetooth Europe CE 117 37823 1 US FCC ID QoQBGM111 Canada IC 5123A BGM111 Japan MIC R 209 J00192 Korea KC MSIP CRM BGT BGM111 China SRRC C...

Page 9: ... Approvals Ex I S ATEX DEKRA 13ATEX0098 X II 3 G Ex nA IIC T5 Gc IECEx DEK 13 0026 X Ex nA IIC T5 Gc c FM us FM18US0268X FM18CA0129X FM US CL I Div 2 Gp A B C D T5 CL I Zn 2 Grp IIC T5 FM CA CL I Div 2 Gp A B C D T5 ...

Page 10: ...tor authentication is enabled by default Log functionality By selecting the LOG INT menu item it is possible to set the log interval in seconds Valid selections are 1 9999 s You can also choose to reset the stored log in the menu item LOG DEL The logging function exits automatically if the PR 4512 is detached If the PR 4512 is placed back on the same device the logging will continue In the event o...

Page 11: ...ll be overwritten Backup of device configuration If you want to back up the 4000 9000 product configuration remember to save the configuration in the PR 4512 under the menu point MEM in the ADV SET menu The saved configuration can later be imported into PReset see Import of saved device configuration on page 18 ...

Page 12: ... DEL LOG OK LOG INT OK Monitor 5 NO 7 9 NO 6 v v v YES YES 1 NO NO 1 9999 Menu is shown only if a log exists 2 Menu is shown only if log is started and no log is present in the device ORIEN NO ROT DEV OK Monitor 8 v YES NO The gray shaded menus texts are only shown for guidance and are not part of the 4512 specific submenu Orientation menu is maintaned form 4511 and is still a part of the local 45...

Page 13: ...rface for monitoring and programming of installed PR devices App download If you have already downloaded the PR electronics PPS app from either the Apple App store IOS or Google Play Android check for updates that will add the Bluetooth communication options 2 If you will be downloading the PR electronics PPS app for the first time follow the instructions for IOS below The Android download process...

Page 14: ...h PR 4512 installed 3 In order to identify a specific product in the app each product may be configured with an individual TAG number If needed perform filter items to select specific product types e g all PR 4116 4 Select the desired device and click Connect 5 When a specific product is selected in the PPS the display on the corresponding PR 4512 device will flash indicating that connection has b...

Page 15: ...ice 4 The display on the corresponding PR 4512 device will flash Note As long as a Bluetooth connection is running the active 4512 device wil be flashing Time adjustment The internal clock in the PR 4512 uses Coordinated Universal Time UTC When connecting to a smart device the clock will automatically show local time If the internal clock has drifted by 2 minutes a warning will appear on the smart...

Page 16: ...4 Click Send Analysis of logged data event logging and export 1 Select the period and interval to transfer to the smart device and click the Get log button Note Export intervals must be a multiple of the logged interval If datalogging is done with 5 sec intervals valid export intervals are 5 10 15 9995 2 The available log information is shown ...

Page 17: ...ications in the individual 4000 9000 series product manual PReset software Time adjustment The internal clock in the PR 4512 uses Coordinated Universal Time UTC When connecting to PReset the clock will automatically show local time If the internal clock has drifted by 2 minutes a warning will appear in PReset prompting you to adjust the time Detailed analysis of logged data Use the PR 4590 ConfigM...

Page 18: ...time end time and interval Note Time estimate s is automatically calculated and indicates the data transfer time to PReset Note Export intervals must be a multiple of the logged interval If datalogging is done with 5 sec intervals valid export intervals are 5 10 15 9995 5 Click OK to transfer the data into PReset 6 The following window opens ...

Page 19: ...ow example shows the graph for display value Other options are Relative PV Output Value and Primary Raw Values Event log The below example shows an event log in PReset for a PR 4114 The event log indicates date and time for the occurrence of the event and for when it was cleared For a detailed description of the error codes see the section Error indications in the individual 4000 9000 series produ...

Page 20: ...18 4512V100 UK Import of saved device configuration 1 Click on the Receive icon 2 Select the tab Configuration ...

Page 21: ...4512V100 UK 19 Document history The following list provides notes concerning revisions of this document Rev ID Date Notes 100 2002 initial release of the product ...

Page 22: ...entation We are headquartered in Denmark and have offices and authorized partners the world over We are a local business with a global reach This means that we are always nearby and know your local markets well We are committed to your satisfaction and provide PERFORMANCE MADE SMARTER all around the world For more information on our warranty program or to meet with a sales representative in your r...

Page 23: ...andards for products communicating monitoring and connecting our customers process measurement points to their process control systems Our innovative patented technologies are derived from our extensive R D facilities and from having a great understanding of our customers needs and processes We are guided by principles of simplicity focus courage and excellence enabling some of the world s greates...