background image

  
 

 

 

PPS25 Electronic Memory Gauge

  

 

 

 

 

 

User Manual (Rev. 04)

 

 

 

 

 

 

 

 

 

 

 

 

Pioneer Petrotech Services Inc. 

 

#1, 1431 - 40th Ave. NE 

Calgary, AB  T2E 8N6, Canada 

 

Phone: 1-888-PP-GAUGE (774-2843) 

E-mail: [email protected] 

Website: www.pioneerps.com 

 

 

Summary of Contents for PPS25

Page 1: ...Electronic Memory Gauge User Manual Rev 04 Pioneer Petrotech Services Inc 1 1431 40th Ave NE Calgary AB T2E 8N6 Canada Phone 1 888 PP GAUGE 774 2843 E mail infopps pioneerps com Website www pioneerps...

Page 2: ...Page 1 REVISION HISTORY Revision Date Comments 00 2002 11 15 Initial release 01 2004 10 10 Additional information for PPS25 gauge 02 2008 04 02 Revision metal to metal seal added to the housing 03 201...

Page 3: ...3 1 Overview 4 3 2 PPS25 Gauge 4 3 3 PPS25 XM Gauge 4 4 Getting Started 5 4 1 Working Mode of PPS25 Gauges 5 4 2 Materials 5 4 3 Inspecting Gauges 6 4 4 Programming Gauges 7 4 5 Activating and Testing...

Page 4: ...essing files from them 2 1 Implementation The Field Service Manager and or Location Manager will ensure that this procedure is implemented 2 2 Supervision The Field supervisor Field Engineer Field Spe...

Page 5: ...n The High sensitivity and stability transducer is good for high accuracy pressure measurement with high resolution low drift and perfect long term stability 3 2 PPS25 Gauge The PPS25 125C 150C 177C m...

Page 6: ...well the battery pack is connected to the electronics and the gauge carries out the program in accordance with the instructions pre stored in the memory Stand by Mode The gauge is in Stand by Mode whe...

Page 7: ...2 Connect a PPS USB download interface to the gauge Fig 1 and a computer to download data and check if the record data is normal 3 Run SmartView and use Diagnostics in Options Tab to test the gauge Fi...

Page 8: ...splay the tool program To make sure that there is no doubt regarding the tool program you can verify it by clicking Clear all Steps and then Get Program from Tool If the program is the same as the one...

Page 9: ...lear All Steps then complete the fields for the required gauge sampling rate and then click Program the Tool Fig 5 Fig 5 For information about power consumption at different sampling rate with differe...

Page 10: ...nt folder if you want to keep all program files in one place naming the file as per the naming convention established for the location ex ABC Oil and Gas Program Sampling rate 1 This will allow you to...

Page 11: ...ttery pack Fig 8 Plug in the battery the battery s LED will turn on Press the black button about 15 sec and release If the battery voltage is lower than 3 2V or 2 6V for dual cell pack repeat previous...

Page 12: ...pack with the slot on the gauge connector You may consider installing batteries in both gauges one set at the same time as you need to try and to initiate both gauges at once this process will avoid t...

Page 13: ...using with the gauge Fig 10 Torque all connections to 70ft Ibs 6 Using a torque wrench and an open end wrench to assemble the bullnose with the gauge at 70ft Ibs The size of wrenches is dependent on O...

Page 14: ...stay at low temperature Get the gauge to downhole ASAP If there is vibration and or shock during downhole operations centralizers and or shock absorbers are recommended to use to protect the gauges Fo...

Page 15: ...y housing of both recorders and try to disconnect both batteries in the same time from both tools this will help you either check the time the batteries were plugged Write it down on the Gauge control...

Page 16: ...k if the gauges are in good condition Or use the Diagnostics function by SmartView software to check your gauges See 4 3 Check voltage of battery packs by a PPS battery tester See 4 5 The lowest requi...

Page 17: ...nual Pioneer Petrotech Services Inc infopps pioneerps com 1 888 PP GAUGE 774 2843 www pioneerps com Page 16 5 1 2 O rings Location Fig 14 PPS25 0 75 PPS25 1 25 PPS25 XM 1 27 Fig 14 O ring 119 2 O ring...

Page 18: ...com 1 888 PP GAUGE 774 2843 www pioneerps com Page 17 5 1 3 O Rings Choices under different conditions H2S or CO2 Pressure kpsi Temperature C O ring 1 O ring 2 Bomb Well 2 25 177 Viton 90 Aflas 90 No...

Page 19: ...solvent Aqueous cleaners for 10mins and then use a small soft brush to clean the diaphragm of pressure sensor Use a clean soft cloth or toilet paper gently wipe 5 1 5 Installing and removing the prote...

Page 20: ...er s maintenance is implemented at PPS manufacturing facility or the authorized representative locations The following maintenance services are performed Full function test Failed components and parts...

Page 21: ...the software Software or drivers are corrupt or damaged Upgrade to latest software version or reinstall ensure USB devices disconnected Interface box is defective Use another interface box Gauge is de...

Page 22: ...ide Diameter 0 75 19 1mm 1 25 4mm 1 25 31 75mm Overall Length 9 228mm 11 297mm Work Mode MRO Housing Material Inconel 718 SS17 4 Service H2S service Sampling Rate 1s 18hrs per sample PPS25 XM Sensor T...

Page 23: ...300 2051 85 20 14 2 405 600 2254 94 30 19 2 300 000 2500 104 60 34 2 168 400 2807 117 PPS25 150C C 150 C battery pack 6 2Ah Sampling Rate s mAs sample Total Points Hours Days 1 2 6 8 584 600 2385 99 5...

Page 24: ...00 5000 208 5 6 7 6 985 000 9701 404 10 9 2 5 086 900 14130 589 15 11 7 4 000 000 16667 694 20 14 2 3 295 700 18310 763 30 19 2 2 437 500 20313 846 60 34 2 1 368 400 22807 950 PPS25 177C CC 180 C batt...

Page 25: ...6 A 1 5 Bull nose 1 25 SS17 4 1 25 bull nose for 1 25 gauge 33 25 0011 A 1 6 Maintenance Kit Aflas 90 212 20pcs Viton90 212 20pcs O ring grease sensor protector remover 01 AC 0071 A1 1 For 1 27 Gauge...

Page 26: ...CC size battery pack 14 01 AC 0014 A1 4 pin 7 PPS 180 C Single CC size battery pack 11 01 AC 0015 A3 4 pin PPS25 Battery Pack for 1 27 housing Item Part Name Capacity Ah P N Connector 1 PPS 150 C Sing...

Reviews: