Page 1: ...er Manual GPS Splitter CR4015 07 02 2019 Pulse Power Measurement Ltd 65 Shrivenham Hundred Business Park Watchfield Swindon Wiltshire SN68TY UK Tel 44 0 1793 784389 Fax 44 0 1793 784391 Email sales pp...

Page 2: ...he equipment PSU modules fused on one input feed see section 4 should be externally fused on both inputs if the polarity of the connectors could be reversed rating should match those given in section...

Page 3: ...8 3 9 LNA feed simulation 9 4 VIALITEHD POWER SUPPLIES 9 4 1 Slide in Chassis AC Power Supplies HPS 1 9 4 2 Slide in Chassis DC Power Supplies HPS 1 DC 10 4 2 1 Fuse replacement in DC Power Supplies 1...

Page 4: ...ovide a modular solution to the transmission of a wide range of analogue and digital data where traditional copper wire systems cannot be used for example in electrically noisy environments or over lo...

Page 5: ...ut power must be isolated from that module Note Each power supply position requires a separate power source to provide fully redundant protection GPS Splitter Rack accommodates up to two single or dua...

Page 6: ...tor the voltage on the alarm output pin will rise to indicate the alarm state It follows that if a module is removed from the chassis the alarm will be raised for that module position The capability o...

Page 7: ...y a single PSU is in use it can be fitted in either position Blanking panels available are 85050 ViaLiteHD Blank Panel 5HP reusable Slots 1 2 in HRK1C Slots 1 3 in HRK1S 85049 ViaLiteHD Blank Panel 7H...

Page 8: ...ted isolated Earth to chassis Chassis earth Rear panel M4 stud Earth to chassis and common with backplane RF GND Common Chassis Connector J1 25 way D 25way Female D with screw lock termination at the...

Page 9: ...n The button supports positive feedback as such the user should feel it activating 4 ViaLiteHD Power Supplies 4 1 Slide in Chassis AC Power Supplies HPS 1 The HPS 1 power supply has an AC input PSU th...

Page 10: ...OFF the power supply is not supplying 12V and has failed These AC power supplies MUST ONLY be fitted in AC chassis types 4 2 Slide in Chassis DC Power Supplies HPS 1 DC The HPS 1 DC power supply has...

Page 11: ...ications for more details The DC power supply is internally fused ONLY on the positive input this fuse will only fail under gross fault conditions The fuse is replaceable access to the fuse is from th...

Page 12: ...ber 0454005 MR Position and replacement of HPS 1 DC fuse 4 3 Specification HPS 1 HPS 1 DC HPS 1 DC24 HPS 1 DC48 Description Wide input range AC power supply Dimensions internal W x H 1U high Dimension...

Page 13: ...one for Right module Rear Panel alarm outputs Power Good on J1 Chassis common connector 12V Normal operation 0V Alarm Cooling Convection MTBF 25 C at 100 load 470 000 hours 150 000 hours 110 000 hours...

Page 14: ...with one finger and pull the module towards yourself with another finger The module can be fully withdrawn If the slot is to be left unpopulated for any period of time please fit the modules inlet wit...

Page 15: ...l Pull the blanking panel towards you it may be necessary to use extra leverage Discard the panel as the plastic barbs will now be over stressed and will not provide a reliable fixing 5 5 Power supply...

Page 16: ...ns on the rear panel allowing redundant gigabit communications links to the embedded SNMP module These are standard optical Ethernet connections and can be connecting into a management network Note Th...

Page 17: ...HRK 1C X HB 1 VIALITEHD 1U GPS SPLITTER HANDBOOK DOCX 17 6 Part Numbering 6 1 ViaLiteHD Chassis part numbering 6 2 ViaLiteHD Power supply part numbering...

Page 18: ...pply type Attach power source Check that rack type AC or DC matches your power source Check that power supply type matches your power source type AC or DC and voltage Difficulty inserting module Incor...

Page 19: ...necessary by accident misuse neglect wilful act or default or any cause other than normal use Claims must be made promptly and during the warranty period IMPORTANT Please contact both your selling age...