FACTORY DEFAULT SETTINGS

1. With the gate still, close the JPROG jumper; 

the SN1 LED will flash twice while the CMD  

button is not pressed ;

2. Press CMD once and then GRV to enter 

the function;

settings or CMD to cancel and return to the 

function menu;

4. Remove JPROG jumper;

SN1 LED:

- Flashes once whenever it recognizes the 

button as pressed

SN2 LED:

- Flashes once;

AUTOMATIC / SEMI AUTOMATIC

TIME

At the end of the opening cycle, the gate 

waits for the set pause time and closes 

mode is enabled.

 The SN1 and SN2 LEDs flash together every 

1 second, indicating decreasing time. 

When the pause time is set to Disabled, 

close.

1.  With the gate still, close the JPROG 

jumper, the SN1 LED will flash twice while 

the CMD button is not pressed;

the function;

3.  Press GRV to increase the standby time 

in automatic  ode or CMD to decrease  

the time.

in the semi-automatic mode;

5.  10-second gradation / max 120 seconds 

6.  Remove JPROG jumper;
Settings:

0 = Automatic mode disabled;

1 = 10-second pause;

2 = 20-second pause;

12= 120-second pause;

SN1 LED:

- Flashes once whenever the CMD button is 

pressed ;

- Flashes once for 10 seconds of the total time, 

eg: 30-sec pause, LED flashes 3 times;

- Flashes continuously - automatic mode 

disabled;

- Remains on when maximum time is enabled;

SN2 LED:

- Flashes twice;

P06105 - Rev. 3

WARNING

Do not use the equipment 

without referring to this 

manual first . 

CONTROL BOARD

POP PROG

TECHNICAL

MANUAL

COURTESY LIGHT TIME / DELAY

MAIN FEATURES

- Analogic Limit Switch;

- 433.92MHz Receiver Module;

- Capacity for 50 remote controls;

- Electronic clutch adjustment (strength);

- Automatic memorization (Opening/Closing); 

- Inputs:

Photocell (uses external power source);

Pushbutton;

- Outputs for modules:

Electromagnetic Lock;

Courtesy light;

- Brake adjustment;

- Limit switch adjustment;

- Ramp torque adjustment;

- Opening delay for Traffic Light activation;

- Settings via PROG PPA.

Factory Default Setting

Travel time

2 Minutes, max time

Automatic timing

Disabled

Courtesy Light Time

Traffic light (0 second)

Brake

Level 1

Strength

Level 8, maximum

Opening Ramp

Disabled

Closing Ramp

Disabled

Opening Ramp Torque

Level 6

Closing Ramp Torque

Level 6

DEFAULT SETTINGS CHART

1 - Default

Open Function CMD once

Enter Function GRV once

GRV once

Cancel CMD once

2 - Auto Timing

Open Function CMD twice Enter Function GRV once

Increase GRV once

Decrease CMD once

3 - Erase TX

Open Function CMD 3x

Enter Function GRV once

GRV once

Cancel CMD once

Open Function CMD 4x

Enter Function GRV once

Increase GRV once

Decrease  CMD once

5 - Not used

6 - Brake

Open Function CMD 6x

Enter Function GRV once

Increase GRV once

Decrease CMD once

7 - Strength

Open Function CMD 7x

Enter Function GRV once

Increase GRV once

Decrease CMD once

8 - Opening Ramp

Open Function CMD 8x

Enter Function  GRV once

Decrease Distance CMD once

9 - Closing Ramp

Open Function CMD 9x

Increase Distance GRV once

Decrease Distance CMD once

FUNCTION CHART

Enter Function  GRV once

Increase Distance GRV once

10 - Opening

Ramp Torque

Open Function CMD 10x

Enter Function  GRV once

Decrease Torque CMD once

Increase Torque GRV once

11 - Closing

Ramp Torque

Open Function CMD 11x 

Enter Function  GRV once

Decrease Torque CMD once

Increase Torque GRV once

4  - Courtesy Light 

Time / Delay

Confirm

Confirm

Sets the time to turn off the relay 

module of the courtesy light when the 

gate reaches the closing limit switch or 

the pause time for the gate to start 

opening after the activation of the relay 

module connected to the "LIGHT" output 

(Traffic Light).

For the Courtesy Light Time:

The setting has levels from 0 to 7, max 

time = 4 minutes. 

Operation: The garage light will turn on 

whenever the gate is in motion or is 

open waiting for a new command, and 

will be turned off when the gate fully 

closes and after the scheduled time has 

elapsed.

For Opening Delay with Traffic Light 

activated:

The setting has levels from 8 to 120, max 

time = 16 seconds.

Operation: When the gate is fully closed 

and when it receives a command for the 

opening cycle, the traffic light will be 

activated and on for the set time and 

then the motor will be activated. The 

traffic light will be deactivated at the end 

of the door closing cycle or when a new 

command by remote control is received 

during the delay time.

1. With the gate still, close the JPROG 

jumper, SN1 LED will flash twice while the 

CMD button is not pressed;

2. Press CMD 4 times and then GRV to 

enter the function;

ERASING REMOTE CONTROLS

Erases the memory to add new remote 

controls.

1. With the gate still, close the JPROG 

jumper, LED SN1 will start flashing twice 

while the CMD button is not pressed;

2. Press CMD 3 times, then GRV to enter 

function;

3. PPress GRV to erase controls or CMD to 

cancel and return to the function menu;

4. Remove JPROG jumper;

SN1 LED:

- Flashes once whenever a button is 

pressed;

- Flashes 10 times fast, confirming the 

exclusion of the remote controls;

SN2 LED:

- Flashes 3 times;

Restores the settings to the factory default.

3. Press GRV to confirm the factory default

automatically whenever the automatic 

the gate waits for the next command to 

2. Press CMD twice and then GRV to enter

4. Whenever the time is reset, the gate remains

Return travel time to 1 minute. 

1. Gate must be still;

2. With Jumper JPROG open, press GRV + button  

for 3 seconds.

3. SN1 and SN2 LEDs flash, confirming the 

operation  

- Starting and leaving the program: SN1 LED (red)

 flashes once, slowly;

- Last Command - Opening: SN2 LED (green) 

flashes 3x, fast;

- Last Command - Closing: LED SN1 flashes 4x, fast;

- Photocell triggered: LED SN1 remains lit.

3. Press GRV to increase courtesy light time or 

CMD to decrease;

4. 30-second-gradation;

5. Max time = 4 minutes;

6. The delay setting has levels from 3 to 16 

seconds, with a 3-second gradation;

7. Remove JPROG jumper.

Levels

0 - 0 second (Traffic Light)

1 - 30 seconds

2 - 60 seconds

3 - 90 seconds

4 - 120 seconds

5 - 150 seconds

6 - 180 seconds

7 - 240 seconds

Delay times, levels:

8 - 3 seconds

9 - 7 seconds

10 - 10 seconds

11 - 13 seconds

12 - 16 seconds (max)

SN1 LED:

- Flashes once whenever a button is pressed;

- Flashes continuously to minimum time, level 0;

- Remains lit when maximum time is enabled; 

- Flashes once at each level, eg level 6, LED 

flashes 6x.

SN2 LED:

- Flashes 4x;

BRAKE

When there is a command to switch off the 

motor, the brake will be activated with the 

possibility of adjusting the sensitivity.

1. With the gate still, close the JPROG jumper, 

LED SN1 will flash 2x while the CMD button is 

not pressed;

2. Press CMD 6 times and then GRV to enter the 

function;

3. Press GRV to increase the brake sensitivity;

4. Press CMD to decrease the brake sensitivity;

5. In the minimum level, the brake is disabled, 

with the possibility of adjustment of 10 levels of 

sensitivity.

SN1 LED:

- Flashes continuously for Minimum level, brake 

disabled;

- Flashes once for each increment of sensitivity, 

maximum level = 10; 

FORCE (ELECTRONIC CLUTCH)

Adjusts the engine operating force. 

In order for this safety-sensing device to be 

SN1 LED:

- Flashes once whenever a button is pressed;

- Flashes continuously for minimum setting, 

disabled;

- Flashes once for each increment of sensitivity, 

with maximum value equal to 12;

- It remains lit at maximum value.

SN2 LED:

- Flashes 8x for opening;

- Flashes 9x, for closing.

RAMP TORQUE

The control unit will decrease the operating 

torque as soon as it reaches the programmed 

ramp. The torque is set separatedely for 

opening and closing.

1. With the gate still, close the JPROG jumper. 

The SN1 LED will start flashing twice while the 

CMD button is not pressed.

2. Press CMD 10x for opening ramp torque 

and 11x for closing ramp torque and then 

GRV to enter the function;

3. Press GRV to increase the torque;

4. Press CMD to decrease the torque;

SN1 LED:

- Flashes once whenever a button is pressed;

- Flashes continuously to minimum setting;

- Flashes once for each increment of sensitivi-

ty, with maximum level = 8;

- It remains lit at maximum level.

SN2 LED:

- Flashes 10x (Opening);

- Flashes 11x (Closing);

ADDING REMOTE CONTROLS

PPA standard remote controls.

1. With the gate still, close the JPROG 

jumper, SN1 LED will flash twice;

2. Press a button of the remote control, SN2 

LED will start flashing whenever it receives a 

valid code;

3. Press and release the GRV button;

4. Release the button of the remote control;

5. If the control has been successfully added, 

SN1 and SN2 LEDs flash;

6. If the button had already been added SN1 

LED flashes twice;

7. Full memory,  SN1 LED flashes 3 times;

8. To add a new control, go back to step 3;

9. Remove JPROG jumper to finish;

EXTRA INDICATION ON 
LEDs

ELECTRICAL WIRING

effective, proceed as follows:

- After proper installation of the automator on 

the gate, adjust the electronic clutch, so that 

the force is the minimum required to move the 

gate leaf throughout its path, opening and 

closing;

- At the end of the adjustment, test the 

function by blocking the movement of the gate 

by placing a rigid object in the course of the 

gate.

1. With the gate still, close the JPROG 

jumper, the SN1 LED will flash 2x while the 

CMD button is not pressed;

2. Press CMD 7x and then GRV to enter the 

function;

3. Press GRV to increase the force or CMD 

to decrease;

4. Maximum strength level: 8;

5. Remove JPROG jumper;

SN1 LED:

- Flashes once whenever a button is 

pressed;

- Flashes continuously for minimum 

strength, level 0;

- Remains lit for maximum strength, level 

7.

- Flashes once according to selected level, 

eg: level 3, LED flashes 3x.

SN2 LED:

- Flashes 7x;

ADJUSTING THE OPENING 

/ CLOSING RAMP

The ramp is the remaining distance to 

reach the mechanical stop.

The control unit will continuously monitor 

the position of the gate and when it 

reaches this limit, the speed of operation 

decreases, reaching the mechanical stop

gently.

1. With the gate still, close the JPROG 

jumper, LED SN1 will flash twice while the 

CMD button is not pressed;

2. Press CMD 8 times for opening limit 

switch, or press CMD 9 times for closing 

limit switch and then GRV to enter the 

function;

3. Press GRV to move the limit to the 

mechanical stop away, increasing the 

distance;

4. Press CMD to decrease the distance to 

the limit switch;

5. In the minimum value the ramp is 

disabled; it does not decrease the torque, 

with the possibility of adjustment of 12 

levels of sensitivity.

SINGLE-PHASE 
INDUCTION 
MOTOR

ELECTRICAL 

NETWORK 

127/220V

VOLTAGE 
SELECTION 
JUMPER

PROGRAMMING 

JUMPER

INDICATOR

LEDS

(OPTIONAL) COURTESY 

LIGHT RELAY MODULE

ENGINE START 

CAPACITOR

(OPTIONAL) LOCK 

RELAY MODULE

PROG BY PPA

PHOTOCELL

PUSHBUTTON

CONFIGURATION 

BUTTONS

CLS

OLS

LIMIT SWITCH

ERASING A PATH