PowMr POW-HPM Series Manual Download Page 1

1

Important Safety Instructions

Please save these instructions for future use!

Please keep this manual for future use.

This manual contains all safety, installation and operating instructions for the POW-HPM Series all-in-one

solar charge inverter. Please read all instructions and precautions in the manual carefully before installation

and use.

Non-safety voltage exists inside the all-in-one solar charge inverter. To avoid personal injury, users shall not

disassemble the all-in-one solar charge inverter themselves. Contact our professional maintenance personnel

if there is a need for repair.

Do not place the all-in-one solar charge inverter within the reach of children.

Do not install the all-in-one solar charge inverter in harsh environments such as moist, oily, flammable or

explosive, or heavily dusty areas.

The mains input and AC output are high voltage, so please do not touch the wiring terminals.

The housing of the all-in-one solar charge inverter is hot when it is working. Do not touch it.

Do not open the terminal protective cover when the all-in-one solar charge inverter is working.

It is recommended to attach proper fuse or circuit breaker to the outside of the all-in-one solar charge inverter.

Always disconnect the fuse or circuit breaker near the terminals of PV array, mains and battery before

installing and adjusting the wiring of the all-in-one solar charge inverter.

After installation, check that all wire connections are tight to avoid heat accumulation due to poor connection,

which is dangerous.

The all-in-one solar charge inverter is off-grid. It is necessary to confirm that it is the only input device for load,

and it is forbidden to use it in parallel with other input AC power to avoid damage.

Summary of Contents for POW-HPM Series

Page 1: ...oily flammable or explosive or heavily dusty areas The mains input and AC output are high voltage so please do not touch the wiring terminals The housing of the all in one solar charge inverter is ho...

Page 2: ...15 2 4 4 SCHEMATIC DIAGRAM OF PARALLEL CONNECTION IN SPILIT PHASE 18 3 OPERATING MODES 22 3 1 CHARGING MODE 22 3 2 OUTPUT MODE 23 4 LCD SCREEN OPERATING INSTRUCTIONS 24 4 1 OPERATION AND DISPLAY PANE...

Page 3: ...d outputs pure sine wave to convert DC into AC It is ideal for AC loads such as household appliances power tools industrial equipment and electronic audio and video equipment The product comes with a...

Page 4: ...d while charging the battery If the mains or generator is not connected the system can also operate normally and the load is powered by the battery and PV module 3 Battery Provided to ensure normal po...

Page 5: ...contact port AC input port Cooling fan AC output port Battery port Grounding screw hold Cooling fan RS485 2 communication port PV port Current sharing port parallel module only Function key Parallel c...

Page 6: ...6 1 4 Dimension drawing In...

Page 7: ...with ties to avoid looseness of connections caused by shaking of wires during mobile application The system connection wires are selected according to a current density of not more than 5 A mm2 Avoid...

Page 8: ...for recommended AC input wire diameter and switch Models Recommended AC input wiring diameter Maximum bypass input current Recommended circuit breaker type POW HPM5 6KW 10mm2 7AWG 40A 2P 40A Note The...

Page 9: ...verter ensure that there is enough air flowing through the heat sink and space of at least 200m m to the left and right air outlets of the inverter shall be left to ensure natural convection heat diss...

Page 10: ...and confirm that the wire used is thick enough Please refer to Section 2 2 Wiring Specifications and Circuit Breaker Selection Properly connect the AC input wire according to the wire sequence and te...

Page 11: ...ck as possible cross sectional area is not less than 4mm2 The grounding point shall be as close as possible to the all in one solar charge inverter The shorter the grounding wire the better PV input w...

Page 12: ...will generate high voltage So before wiring be sure to opening the circuit breaker or fuse Be very careful during wiring do not close the circuit breaker or fuse during wiring and ensure that the and...

Page 13: ...n AC loads one by one as the AC output is normal to avoid a protection action caused by a large momentary shock due to simultaneous turning on the loads simultaneously Now the machine goes into a norm...

Page 14: ...nection in split phase Ensure N to N and PE to PE connection for all all in one solar charger inverters The L lines of all inverters connected to the same phase need to be connected together But L lin...

Page 15: ...sure that the red and black current sharing connection lines of each inverter are not manually exchanged and make sure to tighten the lines with self contained screws to avoid the abnormal operation o...

Page 16: ...th multiple inverters the schematic diagram of parallel connection is as follows a Two all in one solar charger inverters of the system connected in parallel b Three all in one solar charger inverters...

Page 17: ...ne solar charger inverters of the system connected in parallel d Five all in one solar charger inverters of the system connected in parallel e Six all in one solar charger inverters of the system conn...

Page 18: ...screws after connecting The schematic diagram is as follows 2 In case of parallel operation with multiple inverters the schematic diagram of parallel connection is as follows Parallel Operation in thr...

Page 19: ...19 c Five all in one solar charger inverters of the system connected in three phase 3 1 1 system 2 2 1 system...

Page 20: ...20 d Six all in one solar charger inverters of the system connected in three phase 2 2 2 system 3 2 1 system 4 1 1 system...

Page 21: ...andby mode 5 When using parallel or spilit phase separation function the 31 setting items need to be set accordingly Parallel Operation in three phase The 31 setting item All connected P1 phase invert...

Page 22: ...e the battery Only when the Mains fails the PV charging can be activated 3 Hybrid charging PV and mains hybrid charging PV MPPT charging is a priority and when PV energy is insufficient the mains supp...

Page 23: ...hen the unit is equivalent to a backup UPS suitable for areas with unstable grid Switching does not affect PV charging Power supply priority Utility Solar Battery 3 Battery priority mode Switch to mai...

Page 24: ...ion Indicators introduction Function buttons Description SET Enter Exit Settings menu UP Previous choice DOWN Next choice ENT Confirm Enter Options under the settings menu Indicators Colors Descriptio...

Page 25: ...ing battery is 25 49 indicates that the remaining battery is 50 74 indicates that the remaining battery is 75 100 Indicates the percentage of AC output loads indicates that the load percentage is 0 24...

Page 26: ...put voltage AC input frequency PV input voltage internal heat sink temperature software version Parameters display on the right side of the screen Output parameters Indicates output voltage output cur...

Page 27: ...tput current 4 INPUT BATT A Input battery current OUTPUT BATT A Battery output current 5 INPUT BATT KW Battery input power OUTPUT BATT KW Battery output power 6 AC INPUT Hz AC input frequency AC OUTPU...

Page 28: ...er 05 02 Output Frequency 02 50 0 Bypass self adaptation when the mains is connected it automatically adapts to the mains frequency when the mains is disconnected the output frequency can be set throu...

Page 29: ...Battery floating charge voltage 11 55 2V default Floating charge voltage setting range 48V 58 4V step 0 4V valid when battery type is user defined 12 Battery over discharge voltage delay off 12 42V de...

Page 30: ...tic restart when overload is enabled If an overload occurs and the output is turned off the machine will restart after a delay of 3 minutes After it reaches 5 cumulative times the machine will not res...

Page 31: ...r BMS communication 33 Battery BMS communication When the parameter 32 setting item BMS you can choose to match the battery manufacturer s BMS protocol to communicate with BMS for the lithium battery...

Page 32: ...V 55 2V 36 60V Adjustable Under voltage alarm voltage 01 fault 44V 44V 44V 36 60V Adjustable Under voltage alarm voltage recovery point 01 fault Under voltage alarm voltage 0 8V Low voltage disconnect...

Page 33: ...V Adjustable 53 2V Adjustable 49 2 Adjustable Under voltage alarm voltage 01 fault 43 6V Adjustable 46 8V Adjustable 49 6V Adjustable 46 4V Adjustable 43 2V Adjustable Under voltage alarm voltage reco...

Page 34: ...S485 2 Pin 1 is 5V power supply Pin 2 is GND Pin 7 is RS485 A2 and Pin 8 is RS485 B2 5 3 USB communication port This is a USB communication port which can be used for USB communication with the option...

Page 35: ...nd duration refer to the technical parameters table in the manual 10 PV reverse polarity protection When the PV polarity is reversed the machine will not be damaged 11 AC reverse protection Prevent ba...

Page 36: ...oostOCHw No Boost over current hardware protection 12 bLineLoss No Mains power down 13 OverloadBypass Yes Bypass overload protection 14 OverloadInverter Yes Inverter overload protection 15 AcOverCurrH...

Page 37: ...Yes Parallel line connection error in parallel mode 44 Serial number error YES If the serial number is not set by omission in production please contact the manufacturer to set it 45 Error setting of s...

Page 38: ...e of power equipment Restart the unit to resume load output 17 Inverter short circuit protection Check the load connection carefully and clear the short circuit fault points Re power up to resume load...

Page 39: ...oration and tighten the screws 5 Check for dirt nesting insects and corrosion and clean up as required 6 If the arrester has failed replace in time to prevent lightning damage to the unit or even othe...

Page 40: ...equency range Hz 50Hz 0 3Hz 60Hz 0 3Hz Maximum Efficiency 92 Overload protection 102 load 125 10 report error and turn off the output after 5 minutes 125 load 150 10 report error and turn off the outp...

Page 41: ...rger current specifications AC charger PV charger Max charger current can be set 0 80A Certified specifications Certification CE IEC62109 1 CETL UL 1741 C22 2 NO 107 1 EMC certification level EN61000...