Nexus FT
Troubleshooting
044-05251 Rev B
4-3
12
High temp
CU
Warning
The CU PCBA temperature is higher than 90°C
Ceasing
The CU PCBA temperature has fallen below 90°C
13
REFO error
Error
Significant REFO drift or error detected by CU
14
Ext REFO
error
Warning
Suggested remedy: Check the reference source and the cables
15
CU battery
fault
CU
Warning
CU RAM battery fault. The battery for the RAM on the CU PCBA
has a voltage outside the normal 2.7 to 3.5 Volt. An alarm may be
initiated at start-up if the WRH has been stored out of power for a
long time. Suggested remedy: Ensure jumper P3 on the CU PCBA
is mounted to charge the battery
Ceasing
The cause of the alarm has ceased
16
SW load error
CU
Error
Software load error. An error has occurred during a software load
process. The flash memory does not contain a proper software.
Suggested remedy: Check the CU software using the OM-Online
SW Manager. Do NOT restart the WRH
17
Log cleared
CU
None
Log memory has been cleared. The check sum in the Events Log
memory is faulty. The log is cleared. Can be caused of a bad RAM
battery backup or low voltage to the RAM
18
RTC restarted
CU
None
The time is changed by the operator (logged to keep track of
changes made to the RTC)
Warning
Time reset to 1994-01-01. The RTC was unable to keep track of
the time and did a reset. Suggested remedy: Ensure jumper P3 on
the CU PCBA is mounted to charge the battery
19
RTC error
Error
RTC does not operate. The CU has detected an error in the RTC
operation which makes the time unreliable. Suggested remedy:
Replace the CU PCBA
20
Door open
alarm
External
Config
The door has been open 30 seconds without disabling the alarm
Ceasing
The door has been closed 30 seconds, or the alarm is disabled
21
External
alarm 1
External
Config
External alarm input EA1 active more than 1 second
Ceasing
External alarm input EA1 no longer active
22
External
alarm 2
External
Config
External alarm input EA2 active more than 1 second
Ceasing
External alarm input EA2 no longer active
23
External
alarm 3
External
Config
External alarm input EA3 active more than 1 second
Ceasing
External alarm input EA3 no longer active
24
External
alarm 4
External
Config
External alarm input EA4 active more than 1 second
Ceasing
External alarm input EA4 no longer active
Table 4-2 Alarm Troubleshooting (Continued)
ID
Alarm Text
Alarm Unit
Alarm
Description
Summary of Contents for NEXUS FT
Page 8: ...Table of Contents Nexus FT vi 044 05251 Rev B This page intentionally left blank...
Page 44: ...Return For Service Procedures Nexus FT 4 10 044 05251 Rev B This page intentionally left blank...
Page 48: ...Introduction Nexus FT 5 4 044 05251 Rev B This page intentionally left blank...
Page 49: ...044 05251 Rev B A 1...