background image

 

 

  

EN 

 
 
 

Inverter/Charger 

 

PowerWalker Inverter 700 PSW 
PowerWalker Inverter 700 PSW/FR 
PowerWalker Inverter 1200 PSW 
PowerWalker Inverter 1200 PSW/FR 

 
 

  

 

 

 
 
 
 

Quick Start Guide  

 
 

EN 

 

 
 
 

Summary of Contents for 700 PSW

Page 1: ...EN Inverter Charger PowerWalker Inverter 700 PSW PowerWalker Inverter 700 PSW FR PowerWalker Inverter 1200 PSW PowerWalker Inverter 1200 PSW FR Quick Start Guide EN ...

Page 2: ...brilliant choice for home owners or small office users in the unstable power area PowerWalker Inverter 700 1200 PSW FR series provides a variety of features Pure sine wave inverter Selectable input voltage range for home appliances and personal computers Seletable charging current Auto restart while AC is recovering Overload and short circuit protection Generators Computer related devices compatib...

Page 3: ...anel Power switch Display indication please see the Operation section for the details Back Panel Input voltage range selector AC input Input breaker External battery connector Charge current selector Output receptacles French Schuko ...

Page 4: ...ts 1 Single battery connection Refer to Fig 1 When using a single battery its voltage must be equal to the Nominal DC Voltage of the unit II Multiple batteries in series connection Refer to Right fig All batteries must be equal in voltage and amp hour capacity The sum of their voltages must be equal to the nominal DC Voltage of the unit Note when connecting batteries in series connection it s nece...

Page 5: ...or lower than this range the unit will transfer to inverter mode automatically And you can connect the computer systems or other precision home equipment when you select this operation mode b 90V 280V setting for home appliances If you select this mode the unit s input utility range will be extended to 90 280VAC If the utility is higher or lower than this range the unit will transfer to inverter m...

Page 6: ... relay failed led F09 Main relay failed F11 Beep Continuously sounding The unit will shut down after it s in fault mode for 15 seconds Battery weak at battery mode The mark will flash every second Beep once every 1 second The unit is waning of overload The mark will flash every second Beep once every 0 5 second Power limitation warning in Line mode The mark will flash every second Beep twice every...

Page 7: ...c and quantity of batteries are meet requirements Fault code 01 Fan fault Replace the fan Fault code 06 Output abnormal Inverter voltage below than 190Vac or is higher than 260Vac 1 Reduce the connected load 2 Return to repair center Fault code 08 Internal components failed Return to repair center Mains exist but the unit works in battery mode Input voltage is displayed as 0 on the LCD Input prote...

Page 8: ...hort circuit Return to repair center If there is any abnormal situations occur which doesn t list above please call the service people immediately for professional examine 6 Specifications MODEL Inverter 700 PSW Inverter 700 PSW FR Inverter 1200 PSW Inverter 1200 PSW FR CAPACITY 700VA 500W 1200VA 840W INPUT Voltage 230VAC Voltage Range 170 280 VAC For personal computer 90 280 VAC For home applianc...

Reviews: