20
This.PowerVent.water.heater.contains.an.accessory.kit.for.
installing.the.User.Display .
User.Display.Mounting.Kit.–.AS42461
.
a ....Optional.Water.Heater.Mounting.Bracket.–.
AP14752
.
b ...12.feet,.18.AWG.Thermostat.Wire.–.AP14820
.
c ...Optional.Mounting.Tape.–.AP14819
.
d ...Transformer.Enclosure.–.AP14875
.
e ....Screw,.#8.x.½".Self.Drilling.qty.2.AP5925GS
.
f ...User.Display.–.AP14697
Installation.Instructions:
!
CAUTION:..Turn.the.switch.on.the.blower.to.the.
“off”.position.and.disconnect.power.to.the.water.heater.
before.proceeding!
1 ....Locate.the.electrical.connection.for.the.Transformer.
Enclosure.on.the.top.of.the.water.heater ...This.
electrical.connection.features.a.white.6-pin.plug.and.
white.heat.shrink .
2 ....The.Transformer.Enclosure.features.a.6-pin.connection.
located.on.the.circuit.board.inside.the.enclosure ...
Attach.the.top.pan.harness.connector.to.this.6-pin.
connector.in.the.correct.orientation .
3 ....Locate.the.two.screw.pilot.holes.on.the.water.heater.
top.to.attach.the.Transformer.Enclosure.to.the.top.pan ...
Position.the.enclosure.so.the.terminal.strip.opening.
is.visible.from.the.front.of.the.water.heater ...Secure.
enclosure.to.top.pan.with.screws.provided.in.the.User.
Display.Mounting.Kit.without.pinching.any.wires .
NOTICE: Do not over tighten to avoid cracking
plastic enclosure.
4 ....Determine.where.the.User.Display.will.be.located ...
The.display.can.be.attached.to.the.water.heater.jacket.
with.supplied.Water.Heater.Mounting.Bracket.or.
mounted.remotely.to.a.wall.via.the.wall.plate.up.to.100.
feet.away.using.18.AWG.solid.copper.thermostat.wire ...
Any.installation.location.over.12.feet.from.the.water.
heater.will.require.additional.thermostat.wire ...(Not.
supplied .)
5 ....If.remote.mounting,.go.to.step.19 .
6 ....Cut.enough.thermostat.wire.from.the.12.feet.
provided.to.connect.the.front.mounted.display.to.the.
Transformer.Enclosure.located.on.the.top.pan .
7 ....Strip.½”.insulation.from.the.3.wires.on.both.ends ...
The.wire.provided.is.standard.3-wire.with.the.colors.
GREEN,.RED.and.WHITE .
8 ....Connect.one.end.of.the.wire.to.the.Transformer.
Enclosure.spring.terminal.strip ...From.left.to.right.
colors.shall.be.GREEN.–.RED.–.WHITE ...Wires.
should.easily.insert.into.the.terminal.strip ...If.required.
for.wire.insertion.or.removal,.use.small.flat.blade.
screw.driver.to.press.the.tab.located.below.each.wire.
hole .
9 ....Remove.two.strips.of.Display.Mounting.Tape.and.
attach.to.the.inside.flanges.of.the.Water.Heater.
Mounting.Bracket .
Installing the Optional User Display
Transformer
Pin.Plug
6.Pin.Connection.for.to.
Circuit.Board
Mounting.Holes.for.
Transformer
Display.Mounting.
Tape.Strips
Water.Heater.
Mounting.Braket.
for.Display
Flange.of.Mounting.