background image

160W Folding Solar Panel 

ZM9178

 

Summary of Contents for ZM9178

Page 1: ...160W Folding Solar Panel ZM9178 ...

Page 2: ... or short circuit it is recommended to place a blanket or tarp over the panels or block out any sunlight temporarily while all connections are made 3 Care must be taken when handing this product and while in use 4 Keep away from any flammable substances 5 Make sure to connect with correct polarity 6 Battery must be removed from the confines of a vehicle when connected to the solar controller 7 Alw...

Page 3: ...s to the suitable angle Step 3 Always face the front side of solar panels toward the sun Wipe down the panels with a microfiber cloth to remove any dust or debris Note To ensure maximum possible output we recommend that the solar panels are regularly re aligned to follow the sun s movement Wipe the solar panel with microfiber cloth for maximum efficiency ...

Page 4: ...ator Battery connection may be wired to one battery or a battery bank 2 Overview The 12V 10A regulator is a PWM charge regulator with USB output that uses the most advanced digital technique Regulator features as follows Support 3 charging options AGM Gel FIooded lead acid battery Battery status LED indicator indicates battery situation The USB will provide power supply that can charge electronic ...

Page 5: ...lar panel icon Solar panel is connected to battery 7 Input Connected battery is being charged 8 Battery is connected to solar panel 9 Output Device is connected via USB 10 Connected battery in use to charge USB connected device 11 Voltage battery type connected or charge hours 12 Voltage 4 ...

Page 6: ...ttings Use UP DOWN to set the pa amete long p ess MENU again to ex几 LI I II五 牖9 D Work Mode 0 Discharge Stop INSTALLATION SEQUENCE Charging will stop if the battery falls below the selected Discharge Stop voltage Default is 10 7V The regulator is only suitable for lead acid OPEN AGM and GEL batteries It is not suited for nickel metal hydride lithium ion or other batteries 1 Battery to Controller 2...

Page 7: ... over discharging Power will recommence once the battery voltage reaches the Discharge Reconnect voltage Pre set at 12 6v 5 WORK MODE Pre set at 24H This means the output to the output terminal and USB will always be active as long as there is sufficient power in the battery Other hour settings mean that the output to the output terminals and the USB will continue for the set period of time after ...

Page 8: ...t load battery indicators stay at the same level even after charging for a long period of time The battery is damaged or has died and no longer holds an adequate charge Replace the battery Battery indicator on regulator flashes no output The battery is over discharged Disconnect the load from the battery and charge the battery for a longer period of time There is no voltage output reading from the...

Page 9: ... maintain the long term and trouble free performance of your solar panel system it is recommended that you follow these guidelines prior to each operation Always check to ensure that the product is clean and in good working condition with no visible defects or damage Ensure that the environment where the solar panel system is going to be placed has adequate ventilation Make sure that all connectio...

Reviews: