13. USB Pen Drive FW Update Procedure
14. LOG files Extraction Procedure
All updates for the Ottocanali’s FW are stored within the Armonía Forum.
http://www.powersoft-audio.com/en/downloads/firmware
Download the package, the name should appear as: update-v1.7.6.30-8ch.bin
Extract the compressed file and place it in the USB Pen Drive.
Plug the USB Pen Drive with the firmware update file in
the USB port in the front panel of the amplifier.
Feedback of a properly configured USB Pen Drive is
given by a scrolling text on the front panel stating “USB”.
B
C
D
E
F
G
H
A
CALL
SOFT RESET
HARD RESET
FW UPDATE
PWS OUT
ENERGY
SAVE
ON
OFF
CH 1-2 CH 3-4 CH 5-6 CH 7-8
ON
OFF
B
C
D
E
F
G
H
A
CALL
SOFT RESET
HARD RESET
FW UPDATE
PWS OUT
ENERGY
SAVE
ON
OFF
CH 1-2 CH 3-4 CH 5-6 CH 7-8
ON
OFF
Switch the amplifier on and wait for the completion of the
boot sequence.
Keep pressed the FW UPDATE pushbutton until the front
LED bars start blinking.
The update process lasts in 3-5 minutes. At the end the
system reboots and it is possible to extract the USB
storage device.
Place a FAT32 Formatted USB Pen Drive in the USB Port
on the Ottocanali’s front panel.
Wait until the front panel displays the scrolling “USB”
caption.
Press the “CALL” button for 3 seconds.
The amplifier’s front panel should now display a series
of arrows.
Wait for these arrows to disappear and extract the Pen
Drive.
Place the USB drive in a PC, look for the file: LOG.CSV