POWX1197
EN
Copyright © 2022 VARO NV
P a g e
|
9
www.varo.com
10 CLEANING AND MAINTENANCE
Attention !Before performing any work on the equipment, pull the power
plug.
10.1
Cleaning
▪
Keep the ventilation slots of the machine clean to prevent overheating of the engine.
▪
Regularly clean the machine housing with a soft cloth, preferably after each use.
▪
Keep the ventilation slots free from dust and dirt.
▪
If the dirt does not come off use a soft cloth moistened with soapy water.
Never use solvents such as petrol, alcohol, ammonia water, etc. These
solvents may damage the plastic parts.
11 TECHNICAL DATA
Rated Voltage
230-240 V
Rated Frequency
50 Hz
Rated Power
1500 W
Rotation speed
300-800 min
-1
Protection class
II
Drill capacity concrete
32 mm
Drill capacity steel
13 mm
Drill capacity wood
40 mm
Impact rate
1500-4000 min
-1
Cable length
2 m + VDE plug
12 NOISE
Noise emission values measured according to relevant standard. (K=3)
Acoustic pressure level LpA
93 dB(A)
Acoustic power level LwA
104 dB(A)
ATTENTION! Wear hearing protection when sound pressure is
over 85 dB(A).
aw (Vibration)
16,4 m/s²
K = 1,5 m/s²
13 SERVICE DEPARTMENT
▪
Damaged switches must be replaced by our after-sales service department.
▪
If the connecting cable (or mains plug) is damaged, it must be replaced by a particular
connecting cable which is available from our service department. Replacement of the
connecting cable must only be carried out by our service department (see last page) or by
a qualified person (qualified electrician).