PowerMax PM4-15 Installation & Maintenance Instructions Download Page 1

 

 

 

 

 

 

 

AC to DC Converter/Charger 

 

AC to DC 

CONVERTER/CHARGER 

 

PM4 models 15, 35, 45, 55, 60, 65, 75, 100 

and 120 Amp with Built-in 4 Stage Smart 

Charging and Fixed Output Modes

 

 

Installation & Maintenance 

Instructions

 

 

 

 

1. 

DISCONNECT DC POWER. 

Disconnect the battery POS (+) wire at the battery end before connecting this Converter/Charger to any 

vehicle/device wiring. 

 

2. 

LOCATION. 

The mounting location may be on any interior (out of direct weather) surface. Location chosen must be accessible after 

installation. When mounted inside a cabinet, the cabinet must be large enough to allow dissipation of heated air. Make sure that there is a 
minimum of 1” (one inch) free air space at each end of the unit so that cooling air can move through the unit properly. AVOID foreign 
contaminants such as dirt, metal particles or moisture. 

 

3. 

MOUNTING. 

Flanges with holes are provided for ease of mounting using standard fasteners. Confirm that the surface that the converter is 

mounted to is solid and will hold the weight (6 lbs) during vehicle operation. 

 

4. 

ELECTRICAL REQUIREMENTS. 

120 VAC 

receptacle needs to be located within 36 inches of the Converter/Charger to supply power. 

Electrical consideration should also be given to mounting near the locations of the batteries and the 

12-volt DC 

distribution panel. 

 

5. 

ELECTRICAL CONNECTIONS

.  Be sure to tighten all connections securely. A loose connection can quickly cause terminals and wires to 

overheat. Review unit labels for recommended terminal torque values. 

 

6. 

THE FAN WILL NOT RUN ALL THE TIME. THE FAN IS TEMPETUR CONTROLD AND WILL ONLY RUN WHEN NEEDED

 

 

Never Leave the PowerMax PM4-XX unattended when plugged in.  

 

7. 

All PM4 Products must be installed by a certified electrician. 

 

 

 

120 VAC 

Connection – First confirm that the 

120 VAC 

power source AC circuit breaker(s) are in the 

breakers until installation is complete. 

position. 

DO NOT 

turn-on AC circuit 

 

Using an 8 AWG minimum size copper wire, attach from the vehicle/device chassis to the Converter/Charger Bonding Lug. 
Using the attached power cord on the Converter/Charger, connect firmly to the 

120 VAC 

receptacle 

 

12 VDC 

Wiring– It is important to use the correct wire gauge. Use a minimum of 8 AWG size copper wire. 

 

The terminal marked 
The terminal marked 

or 

POS 

is for the RV 

12 VDC positive 

connection. 

or 

NEG 

is for the RV 

12 VDC negative 

connection. 

The 

12 VDC 

output wiring does not require over-current protection because the Converter/ Charger limits current output. However, all 

electrical connections need to comply with the appropriate NEC code. 

 

 
 

FOR YOUR SAFETY, READ ALL INSTRUCTIONS BEFORE INSTALLATION AND OPERATION. 

 

INSTALLER: 

Provide these instructions to the end user or consumer. 

CONSUMER: 

Keep these instructions for future reference. 

 

NOTICE: Products are not to be used nor are warranted in aerospace, medical or life safety applications. 

SAFETY ALERT 

 

 

 

120 VAC 

is present. This Converter/Charger is designed to convert 

120 VAC 

to 

12 VDC

. It also provides low voltage 

power for charging on-board 

12 VDC 

batteries. The Converter/Charger is a “

switch mode

” type and is designed to be 

maintenance-free with no user serviceable components. The Converter/Charger power output is “

current limiting

” by 

design. 

WARNING – Avoid Possible Injury or Death 

 

 
 

NEVER store electrical devices in compartments where flammable liquids (such as gasoline) exist. 
DO NOT mount/install unit in compartments designed for storage of batteries of flammable liquids. 

WARNING – Avoid Personal Injury or Product Damage 

WARNING – Avoid Possible Injury or Death 

off 

– 

Reviews: