background image

RES

ET

OFF

30 AMP TO 20 AMP OUTLET ADAPTER

PF923022

This outlet adapter converts a 120/240 volt 30 amp twist-lock 
outlet to a 120/240 volt 20 amp twist-lock outlet to be used on 
portable generators. The load plugged into the 120/240 volt 20 
amp outlet adapter should not exceed 20 amps.
Turn OFF the generator before plugging in the outlet adapter. Al-
ways disconnect all loads from the generator before starting or 
stopping the generator. To turn on the power to the 20 amp outlet 
adapter, place the reset/on/off switch in the reset/on position. 
Operating voltage and frequency requirements of all electronic 
equipment should be checked prior to plugging them into this 
generator. Damage may result if the equipment is not designed 
to operated within a +/- 10% voltage variation, and +/- 3 hertz 
frequency variation from the generator name plate ratings. 

AC CIRCUIT BREAKER

The circuit breaker is provided to protect the electrical cord 
against electrical overload. Exceeding the 20 amp rating will trip 
the circuit breaker.The circuit breaker may be reset by depressing 
the reset button.

Current in Amperes 

(courant en  

ampères, corriente 

en amperios)

Load in Watts 

(charge en watts, 

carga en vatios)

Maximum Cord Length  

(Longueur maximale du cordon, Longitud máxima del cordón)

At 120V 

(à 120 V, 

A 120 V)

At 240V 

(à 240 V, 

A 240 V)

#8 Wire 

(câble, cable)

#10 Wire 

(câble, cable)

#12 Wire 

(câble, cable)

#14 Wire 

(câble, cable)

#16 Wire 

(câble, cable)

2.5

 300

 600

1000 ft.  

(pieds, pies)

600 ft. 

(pieds, pies)

375 ft. 

(pieds, pies)

250 ft. 

(pieds, pies)

5

 600

1200

500 ft. 

(pieds, pies)

300 ft. 

(pieds, pies)

200 ft. 

(pieds, pies)

125 ft. 

(pieds, pies)

7.5

 900

1800

350 ft. 

(pieds, pies)

200 ft. 

(pieds, pies)

125 ft. 

(pieds, pies)

100 ft. 

(pieds, pies)

10

1200

2400

250 ft. 

(pieds, pies)

150 ft. 

(pieds, pies)

100 ft. 

(pieds, pies)

50 ft. 

(pieds, pies)

15

1800

3600

150 ft. 

(pieds, pies)

100 ft. 

(pieds, pies)

65 ft. 

(pieds, pies)

20

2400

4800

175 ft.  

(pieds, pies)

125 ft. 

(pieds, pies)

75 ft. 

(pieds, pies)

25

3000

6000

150 ft.  

(pieds, pies)

100 ft. 

(pieds, pies)

30

3600

7200

125 ft.  

(pieds, pies)

65 ft. 

(pieds, pies)

40

4800

9600

90 ft. 

(pieds, pies)

988000-647
1-24-12 (REV:01)

A - 120/240 Volt 30 Amp receptacle (réceptacle 120/240 volts, 

 

30 ampères, receptáculo de 120/240 voltios y 30 amperios)

B - Reset/on/off switch (interrupteur de réinitialisation/marche/arrêt, 

interruptor de restablecimiento/encendido/apagado)

C - Outlet adapter (adaptateur de prise adaptador de salida)

D - Power cord (cordon d’alimentation, cordón de corriente)

 

 

DANGER:

 

To reduce the risk of injury, the user 

must read and understand this insert sheet as well as the 
operator’s manual for their portab

le generator 

before using 

this product. 

Do not expose to rain or use in damp loca-

tions. 

Failure to follow all warnings and precautions may 

result in death, serious personal injury, or property damage.

CAUTION:

 

Do not overload the generator’s capacity. 

Exceeding the generator’s wattage/amperage capacity may 
damage the generator and/or electrical devices connected to it.

CALIFORNIA PROPOSITION 65

 WARNING:

 

This product, its exhaust, and other sub-

stances that may become airborne from its use may contain 
chemicals, including lead, known to the State of California 
to cause cancer, birth defects, or other reproductive harm. 

Wash hands after handling.

A

C

D

B

TECHTRONIC INDUSTRIES NORTH AMERICA, INC.

P.O Box 35, Hwy 8, Pickens, SC 29671, USA

1-866-340-3912 

  

n

   

www.powerfittools.com

Reviews: