background image

 

 

PX-S10 / PX-S20 

Owners and 

Installation Manual 

 

 

 

. Main features 

1.  IP68 waterproof and aluminum housing. 
2.  Automatic identification of 12V/24V system voltage. 
3.  LED digital display. 
4.  External temperature sensor for ambient temperature compensation. 
5.  Over  charging  protection,  over  discharging  protection,  over  load,  short  circuit 

protection, reverse polarity protection. 

6.   

. Installation and wiring 

1.  Installation of controller should be stable and dimensions are as follows:   

Overall dimension: 82

×

58

×

20mm (PX-S10)      82

×

100

×

20mm (PX-S20) 

Installation dimension: 43

×

75mm (PX-S10)      86

×

75mm (PX-S20) 

Installation hole diameter: 3.5mm 

 
 

 
 
 
 

 

 

2.  The  controller  can  be  used  for  12V  or  24V  battery  banks.  Once  the  battery  is 

connected it will automatically detect whether it’s connect to a 12V or 24V battery 
bank. For 12 Volt battery banks the digital display will show “0.” when the battery is 
first connected. For 24V battery banks the digital display will show “1.”. So please 
check to ensure it’s detected the correct battery bank size. 

3.  The  controller  is  designed  to  share  the  positive  (+)  pole.  Please  connect  the 

positives  of  storage  battery,  solar  input  and  the  load  (if  being  used)  to  the  red 
(po) wire of the controller 

4.  Connect Battery Black negative (-) wire to the Battery. (Make sure it auto detects 

the correct battery voltage) – We also recommend using adequate size fuse to suit 
your application. 

5.  Connect  Solar  Black  negative  (-)  wire  to  the  Battery:  We  recommend  using 

adequate size fuse to suit your application. 

6.  Connecting  pole  ‘-’o  f  the  load:  connect  the  load  wire  to  the  load  output  end  of 

controller.  Current  should  not  exceed  the  rated  current  of  controller.  We 
recommend using adequate size fuse to suit your application. 
 

Wiring diagram is as follows: Please use adequate size wiring/ fuses. 

 

 

Please install the controller in a ventilated area and close to the battery to ensure the 
battery compensation is effective . 

. Status indications 

LED lamp 

Indications   

LED Status   

Functions   

 

Charging 

indication 

On 

There is voltage on battery panel 

Off     

No voltage on battery panel 

Slow flash     

Charging 

Fast flash 

Over voltage on Solar input 

 

Storage 

Battery 

On 

Battery connected OK 

Off     

Battery is not connected 

Slow flash     

Battery is Low Voltage 

Fast flash   

Battery is deeply discharged   

 

Load   

On 

Load is on 

Off     

Load is off 

Slow flash     

Overload protection mode 

Fast flash   

Short circuit protection mode 

. Modes and Settings 

The PX series controllers have five working modes. 
1.  Purely  light-operated  (0):  When  there  is  no  sunlight,  the  load  output  will  turn  on. 

When there is sunlight the load output will turn off. 

2.  Light-operated  +  time-controlled  (1~4.):  Starting  process  is  same  as  above 

however the load will automatically turn off after the time period selected. Set time 
will be 1 to 14 hours. 

3.  Manual mode (5.): Under this mode, users can control the load-on and load-off by a 

short press of the key/button. This mode is suitable to occasions in need of special 
loads or for debugging. 

4.  Debug mode (6.): It is used for system debug. If there is light signal, load will be 

closed. If there is no light signal, load will be opened. It is convenient for checking 
the correctness of the system during installation and debugging. 

5.  Long-term  On  mode  (7.):  If  being  powered  on,  the  load  will  be  under  the  output 

status all the time. This mode is suitable for loads in need of 24-hour power supply.   

 

LED 

Display 

Mode   

LED 

Display 

Mode   

Purely light-operated 

          9 

Light-op 
time-controlled for 9 
hours 

Light-op 
time-controlled for 1 hour 

0

 

Light-op 
time-controlled for 10 
hours 

Light-op 
time-controlled for 2 hours 

1

 

Light-op 
time-controlled for 11 
hours 

Light-op 
time-controlled for 3 hours 

2

 

Light-op 
time-controlled for 12 
hours 

Light-op 
time-controlled for 4 hours

 

3

 

Light-op 
time-controlled for 13 
hour 

Light-op 
time-controlled for 5 hours 

4

 

Light-op 
time-controlled for 14 
hours 

Light-op 
time-controlled for 6 hours 

5

 

Manual mode 
(Key/button turns load 
on/off) 

Light-op 
time-controlled for 7 hours 

6

 

Debug mode 

Light-op 
time-controlled for 8 hours 

7

 

Long-term On mode 

. How to change settings 

Press  the  mode  key/button  for  more  than  3s  until  the  Display  starts  flashing.  Keep 
pressing  the  key/button  until  it  shows  the  desired  mode/setting.  Once  you  have  the 
correct mode/setting selected, wait for more than 3 seconds and settings will be saved. 

. Safety suggestions 

1.  Please  do  not  immerse  the  controller  into  corrosive  liquid.  Otherwise,  controller 

may be damaged and harmful gas may be generated. 

2.  When connecting 24V system, terminal voltage of battery panel may surpass the 

human  body  safety  voltage.  If  operations  are  needed,  insulating  tools  should  be 
used and hands must be dry.   

3.  If  storage  battery  is  connected  in  reverse,  the  controller  would  not  be  damaged. 

However,  there  may  be  output  of  negative  voltage  at  the  load  end  which  may 
damage anything connected to your load 

4.  Storage battery may generate combustible gas and therefore should be far away 

from sparks. 

5.  Please  make  sure  that  children  are  far  away  from  the  storage  battery  and  the 

controller. 

6.  Please follow the safety suggestions given by the battery manufacturer.   

. Instructions for parameters 

System voltage 

12V/24V Auto 

System current 

10A/20A 

No-load loss 

< 5mA/10A

  < 8mA/20A 

Solar Input Voltage 

PX-S10 - 55VDC Max. 150W(12V) – 300W(24V) 
PX-S20 - 55VDC Max. 300W(12V) – 600W(24V) 

Overvoltage protection 

17.0V / 34V 

Equalising charging 
voltage 

14.7 / 29.4V   

Boost charging voltage 

14.4V / 28.8V   

Float charging voltage 

13.6V / 27.2V 

Return voltage during 
charging 

13.2V / 26.4V 

Return voltage for 
over-discharging 

12.5V / 25V 

Low Voltage Disconnect 

11.5V / 23V 

Temperature 
compensation   

-4.0mv/ /2V; 

Overload and short 
circuit protection 

1.25 times of rated current: 30s; 

1.5 times of rated current: 5s overload protection 

activity; 

3 times of rated current: short circuit protection 

Working temperature 

-35DegC to +65DegC; 

Protection level 

IP68 

Weight   

140g (PX-S10)    300g (PX-S20)     

Dimensions   

82

×

58

×

20mm (PX-S10)    82

×

100

×

20mm 

(PX-S20) 

 

Specifications subject to change without notice : 08/15    Rev 1.1 