background image

PRINTED IN TAIWAN A03-3713420-511 

 
 
 

 

 
Thank you for purchasing the Powerex MH-C9000 
Charger-Analyzer. Read these instructions carefully 
and thoroughly before operating this unit. IMPORTANT 
SAFETY INSTRUCTIONS. READ AND SAVE THESE 
INSTRUCTIONS. 
 

OPERATING THIS PRODUCT INCORRECTLY CAN 

CAUSE DAMAGE TO THE BATTERIES. 

READ MANUAL COMPLETELY BEFORE USE.  

 
 

GENERAL PRECAUTIONS 

 

 

Do not charge battery cells other than NiMH or NiCD. Please check 
with the battery manufacturer to ensure it can accept the 
programmed charging and discharging rates. Do not expose the unit 
to rain or moisture due to the risk of fire. 

 

Do not operate the charger if it appears damaged in any way. 

 

Always place the battery cells with positive tip facing the top. 
Incorrect polarity may cause fire or explosion. Observe polarity 
diagrams located on the charger. 

 

Do not allow the unit to be exposed to direct sunlight. Operate in a 
well-ventilated area. Do not place unit on the carpet.  

 

Do not allow the battery terminals to become shorted. 

 

To reduce the risk of damage to the power cord, always pull by 
connector rather than the cord. 

 

Use only the supplied adapter or optional regional and car adapter 
offered by Maha Energy. Using third party accessories voids the 
product warranty. 

 

 

FEATURES & SPECIFICATIONS 

 

 

Four independent slots for AA or AAA NiMH batteries.  

 

Backlit LCD display. 

 

Digitally displays capacity, voltage, time and current. 

 

Five modes of operation: Charge, Refresh & Analyze, Break-In, 
Discharge and Cycle.  

 

19 selectable charging current from 0.2A to 2.0A. 

 

10 selectable discharging current from 0.1A to 1.0A.  

 

Worldwide power supply.  

 

Charging Current: 

Programmable from 0.2A to 2.0A in 
increments of 0.1A 
 

Topoff Charging Current: 

100mA 
 

Maintenance Charging 
Current: 

10mA 
 

Discharge Termination: 

Voltage 0.90V 
 

Discharging Current: 

Programmable from 0.1A to 1.0A in 
increments of 0.1A 
 

Capacity Storage Memory: 

12 (Cycle mode only) 

Supported Capacity*: 

100 to 20,000mAh 
 

Charger Input Power: 

12V 2.0A  
 

Adapter Input: 

100-240V 50/60Hz  
 

* Always ensure that the batteries can accept the programmed rates.  

 
 

 

 

 
 
 

GENERAL BATTERY EDUCATION 

 

 
What is 0.1C, 0.2C, etc?  

 
“C” stands for the battery capacity and the number preceeding it is the 
fraction of the battery capacity. For example, 0.1C means 0.1 times the 
capacity for the battery. For a 2700mAh battery, 0.1C would be 0.1 times 
2700mAh which equals 270mA.  

 
Choosing the right charging & discharging rate 

 
Charging at a rate below 0.3C and above 1.0C is not recommended.  

 

Charging too slow may prevent the charger from terminating correctly. 
Charging too fast may damage the battery.  
 
Typically speaking, slower charging rate will yield better battery 
performance but requires longer time. Faster charging rate may not 
charge as fully and battery temperature can be higher. 
 
As for the discharging rate, do not exceed 1.0C. 

 

 
Battery Matching 
 

In most devices, usually two or more batteries are used together. When 
batteries are used in a series, the performance is limited by the worst 
one. In other words, one poorly performing battery can significantly 
reduce the device runtime.  
 
Battery matching refers to grouping batteries with similar “actual” 
capacity. To perform this, use the Refresh & Analyze mode to determine 
the battery capacity. Group batteries with capacity within about +/- 5% of 
the rated capacity.  

 
Battery “Forming” 
 

New batteries and those stored for extended period become chemically 
deactivated. Battery forming is a charge-discharge-charge cycle which 
forces a full charge into the battery at a very slow rate. This process 
activates the battery. In certain cases, it needs to be repeated two or 
three times. 
 
Battery forming can be performed using the Break-In mode.  
 
 
 
 
 
 
 
 
 

MH-C9000 

WizardOne Charger-Analyzer 

Summary of Contents for MH-C9000

Page 1: ...rge Termination Voltage 0 90V Discharging Current Programmable from 0 1A to 1 0A in increments of 0 1A Capacity Storage Memory 12 Cycle mode only Supported Capacity 100 to 20 000mAh Charger Input Power 12V 2 0A Adapter Input 100 240V 50 60Hz Always ensure that the batteries can accept the programmed rates GENERAL BATTERY EDUCATION What is 0 1C 0 2C etc C stands for the battery capacity and the num...

Page 2: ...ed frequently at least once every two weeks Charge Batteries in storage for more than two weeks but less than 3 month Refresh Analyze Batteries in storage for more than 3 month Break In Battery Rescue Steps For batteries that do not perform favorably after using the mode recommended above the following sequence can be applied 1 Refresh Analyze for one to three times 2 If capacity is still low use ...

Page 3: ...tion 6 To ensure safety the charger performs a battery health impedance check at the beginning of the program If the battery fails this test HIGH would be displayed and program will be terminated Typically alkaline and extremely aged battery will fail this test For a rechargeable battery it is recommended for the battery to be discarded NOTE This test is not performed for the discharge mode If thi...

Page 4: ...tage If you compare this with a voltmeter while charging the values will not match as a voltmeter is unable to measure the battery voltage during charging or discharging At any given time during the program the charger will either be charging discharging or resting The LCD displays the action in black boxes containing CHARGE DISCHG or REST 8 If CYCLE mode is selected it is also possible to review ...