58
Operation
3.5
Function faults
The following applies when lo-
cating and clearing faults:
Switch the vehicle off, remove
the key from the key switch
and disconnect the battery
plug!
3.5.1 Error code table
In the case of system errors, a four-digit
error code appears in the left-hand op-
erating panel in addition to the service
indicator (wrench symbol).
The dots in the error/service code flash.
Clear the fault or note down the er-
ror/service code and inform your autho-
rized PowerBoss dealer.
Error code
Fault
Cause
Solution
1.2.5.2.
Brushes remain stopped
because the thermostatic
switch has been tripped.
The motor has overheated; for-
eign bodies have possibly
jammed between the brush and
shaft (e.g. tape and such).
• Check the brushes for foreign bodies
and remove them, as necessary.
• Allow the motor to cool down.
• If the problem reoccurs, determine the
cause of overheating; contact an autho-
rized PowerBoss service center, if nec-
essary.
1.2.6.1.
Brushes remain stopped
because the anti-blocking
system has been tripped.
Foreign bodies (e.g. tape or
such) block the brushes.
• Check the brushes for foreign bodies
and remove them, as necessary.
1.2.6.3.
The brush attachment and
brush motors have been
switched off because the
anti-blocking system has
been tripped.
Foreign bodies between the
brush head and vehicle.
• Check the brush head for foreign bodies
and remove them, as necessary.