1.Safety Precautions 

It is very important and necessary to read the user manual carefully before installing or using the 

battery. Failure to follow any of the instructions or warnings in this document can result in 
electrical shock, serious injury, death, or may damage the battery and the whole system.  

If the battery is stored for a prolonged time, it is requirement that they are charged every three to 

six months, and the SOC should be no less than 80%. 

The battery needs to be recharged within 12

 

hours, after fully discharging. 

Do not expose cable outside. 

All battery terminals must be disconnected before maintenance. 

Do not use cleaning solvents to clean the battery. 

Do not expose the battery to flammable or harsh chemicals or vapors. 

Do not paint any part of the battery, include any internal or external components. 

Do not connect battery with PV solar wiring directly. 

Any foreign object is prohibited to be inserted into any part of the battery. 

Any warranty claims are excluded for direct or indirect damage due to items above. 

1.1.

Before Connecting 

After unpacking, please check the battery and packing list first, if the battery is damaged or spare 

parts are missing, please contact the dealer. 

Before installation, be sure to cut off the grid power and make sure the battery is in the turned-off 

mode; 

Wiring must be correct, do not mix-connect the positive and negative cables, and ensure no short 

circuit with the external device; 

It is prohibited to connect the battery with AC power directly; 

The embedded BMS in the battery is designed for 48VDC, please DO NOT connect battery 

in series; 

It is prohibited to connect the battery with different type of battery; 

Please ensure the electrical parameters of battery system are compatible to inverter;  

Keep the battery away from fire or water. 

1.2.

During operation 

If the battery system needs to be moved or repaired, the power must be cut off first and the 

battery is completely shut down; 

It is prohibited to connect the battery with different type of battery; 

It is prohibited to put the batteries working with faulty or incompatible inverter; 

In case of fire, only dry powder fire extinguisher can be used, liquid fire extinguishers are 

prohibited; 

Please do not open, repair or disassemble the battery. We do not undertake any consequences 

or related responsibility due to violation of safety operation or violating of design, production and 
equipment safety standards. 

 

Summary of Contents for YP 51300-15KWH

Page 1: ...Manual For On Off Hybrid Solar Storage System YP5KWH UNIT 15S 48V 4 8Kwh 16S 51 2V 5 12Kwh YP7KWH UNIT 15S 48V 7 2Kwh 16S 51 2V 7 68Kwh YP10KWH UNIT 15S 48V 9 6Kwh 16S 51 2V 10 24Kwh YP15KWH UNIT 51 8...

Page 2: ...uction 6 3 3 SOC Indicator Status Indicator Guides 7 3 4 Connectors 8 3 5 Wake Up button 8 3 6 Display function instruction 9 4 Safe handling guide 10 4 1 System Diagram 10 4 2 Tools 10 4 3 Safety Gea...

Page 3: ...he battery and packing list first if the battery is damaged or spare parts are missing please contact the dealer Before installation be sure to cut off the grid power and make sure the battery is in t...

Page 4: ...C 20 years Life cycles 80 DOD 25 C 6000 Cycles Storage time temperature 5 months 25 C 3 months 35 C 1 month 45 C Operation temperature 20 C to 60 C 60 25 Relative Humidity Storage temperature 0 C to...

Page 5: ...ife cycles 80 DOD 25 C 6000 Cycles Storage time temperature 5 months 25 C 3 months 35 C 1 month 45 C Operation temperature 20 C to 60 C 60 25 Relative Humidity Storage temperature 0 C to 45 C 60 25 Re...

Page 6: ...time 25 C 20 years Life cycles 80 DOD 25 C 6000 Cycles Storage time temperature 5 months 25 C 3 months 35 C 1 month 45 C Operation temperature 20 C to 60 C 60 25 Relative Humidity Storage temperature...

Page 7: ...t installation Integrated state of the art BMS to manage and monitor battery information including voltage current and temperature as well as balance cell charging discharging rates 5 10 years warrant...

Page 8: ...es Chart 1 Battery Status Status Normal Warning Protection RUN ALM Capacity SOC LED Description Shut Down Shut down OFF OFF OFF OFF OFF OFF OFF OFF All OFF Standby Normal Flash OFF Based on capacity S...

Page 9: ...lash ON ON ON ON ON Flash ON ON ON ON ON RUN Status NO Flash 3 4 Connectors Charge Discharge connectors to connect the positive pole and negative pole from the battery to the inverter via DC isolator...

Page 10: ...attery Parameters Acquisition press ENTER key will enter into the page of Battery Parameters Acquisition Battery status page When the cursor is point to Battery Status press ENTER key will enter into...

Page 11: ...n with no keystrokes 1 minutes later system will enter a state of dormancy shutdown Shutdown dormancy state press any key screen can be activated 4 Safe handling guide 4 1 System Diagram 4 2 Tools The...

Page 12: ...3 Safety Gear It is recommended to wear the following safety gear when dealing with the battery pack Insulated gloves Safety goggles Safety shoes 5 Installation 5 1 Inventory of items Thoroughly inspe...

Page 13: ...evel There is minimal dust and dirt in the area Installation must be vertical or tilted backwards by maximum 15 avoid forward or sideway stilt CAUTION If the ambient temperature is outside the operati...

Page 14: ...late mark the hole position 3 Drill 8 holes according to the hole position it is 10 with depth 60mm 4 Hammer the M8 screws to the above holes and screw the nut Note Do not position screws flush to the...

Page 15: ...the maximum connection is 15 units but we recommend 2 4 units according to application When connecting with off grid 48VDC solar inverters it does not need to add Canbus RS485 communication cables wi...

Page 16: ...sion 3 0 2021 7 29 15 www youth power net 5 4 2 Connection Diagram and ADS guide Line If you start to connect hybrid inverter make sure you should consult with YOUTH POWER sales manager before connect...

Page 17: ...version 3 0 2021 7 29 16 www youth power net RS485 Version Max 15 pcs One pc connect diagram...

Page 18: ...version 3 0 2021 7 29 17 www youth power net...

Page 19: ...version 3 0 2021 7 29 18 www youth power net...

Page 20: ...version 3 0 2021 7 29 19 www youth power net...

Page 21: ...r battery with hybrid inverter make sure you should consult with YouthPower sales manager before connection If the hybrid inverter is not from Youthpower factory brand please specify related hybrid on...

Page 22: ...version 3 0 2021 7 29 21 www youth power net 5 4 4 How to set YouthPower Lifepo4 Battery Using as Lead Acid Type Inverters...

Page 23: ...ncluded in the standard pack to combine the power flow of both batteries Combiner Box Photo Connect J1 with inverter s negative pole Connect J2 with inverter s positive pole Add suitable isolators whe...

Page 24: ...rect installation or commissioning Failure to observe the user manual quick installation instructions Incorrect usage or inappropriate operation Insufficient ventilation of the device Failure to obser...

Page 25: ...in and send this page to factory when you need to apply warranty service support Warranty Card User Information Company User Name Address Telephone Email Project installation location Product Informat...

Page 26: ...0 2021 7 29 25 www youth power net POWER INTERNATIONAL ENTERPRISE LIMITED 24 Hrs On line 0086 18185770301 Inquiry Email sales youth power net After Sale Service info youthpowergy com Website www youth...

Reviews: