13
© SPX
Form No. 1000573
Rev. 0 February 8, 2012
Performance Specifications
The information in the following charts can be used as a basis to determine if the system is performing
as expected during operation.
Pump
RPM
Amp Draw at
690 bar (10,000
psi) (115V)
Amp Draw at
690 bar (10,000
psi) (230V)
dBa at Idle
and 690 bar
(10,000 psi)
Air Supply
Req'd bar (psi)
PE10
6
3
68-74
N/A
Pump
Max. Pressure
Output bar (psi)
Fluid Delivery** (cu. in./min. @)
0 bar (0 psi)
7 bar
(100 psi)
50 bar
(700 psi)
70 bar
(1,000 psi)
345 bar
(5,000 psi)
690 bar
(10,000 psi)
PE10
690 bar
(10,000 psi)
120
-
-
-
-
10
** Typical delivery. Actual flow varies with field conditions.
Table 3. Drive Unit Requirements
Table 4. Fluid Pressure Chart