Page 3: ... the contract all statements information and recommendations in this document are provided AS IS without warranties guarantees or representations of any kind either express or implied The information in this document is subject to change without notice Every effort has been made in the preparation of this document to ensure accuracy of the contents but all statements information and recommendation...

Page 4: ...uture The figures in this manual are just for reference for details please see the actual product Suitable Model Inverter PSSi3600W 580VK PSSi5000W 580VK PSSi6000W 580VK Battery iStoragE B8 1 The PV energy storage inverter PSSi 3600 6000W 580VK series consists of inverter and battery 2 Single battery is iStoragE B8 two batteries is iStoragE B16 and so on The PV energy storage inverter PSSi 3600 60...

Page 5: ...h Alerts you to a medium low risk hazard that could if not avoided result in moderate or minor injury Alerts you to a low risk hazard that could if not avoided result in minor injury Anti static prompting Be care electric shock prompting Provides a tip that may help you solve a problem or save time Provides additional information to emphasize or supplement important points in the main text ...

Page 6: ...irements 4 1 1 6 Moisture proof Protection 4 1 1 7 Safety Warning Label Setting 5 1 1 8 Electrical Connection 5 1 1 9 Measurement Under Operation 5 1 2 Safety Precaution for Battery Pack 6 1 2 1 General Safety Precautions 6 1 2 2 Response to Emergency Situations 6 1 3 Requirements for Operator 7 1 4 Environment Requirements 8 2 Overview 9 2 1 Product Intro 9 2 1 1 Model Meaning 10 2 1 2 Features 1...

Page 7: ...Transportation 22 3 3 2 Unpacking and Checking 23 3 4 Installation 24 3 4 1 Single Battery Installation 24 3 4 2 More Batteries Installation 28 3 4 3 Inverter Installation 32 3 5 Electrical Connection 34 3 5 1 Wire Requirement 34 3 5 2 External Grounding Connection 36 3 5 3 DC Input PV Connection 37 3 5 4 Battery Connection 40 3 5 5 AC Output GRID Connection 42 3 5 6 WIFI Connection 45 3 5 7 Commu...

Page 8: ...3 Control Interface 60 5 Startup and Shutdown 65 5 1 Startup 65 5 2 Shutdown 65 6 Maintenance and Troubleshooting 66 6 1 Maintenance 66 6 2 Troubleshooting 66 7 Package Transportation and Storage 78 7 1 Package 78 7 2 Transportation 78 7 3 Storage 78 A Technical Specifications 80 B Acronyms and Abbreviations 85 ...

Page 9: ...ements Before operation please read the announcements and operation instructions in this section carefully to avoid accident The promptings in the user manual such as Danger Warning Caution etc don t include all safety announcements They are just only the supplement of safety announcements when operation Any device damage caused by violating the general safety operation requirements or safety stan...

Page 10: ...r fire Before operation please check if the inverter is damaged or has other danger Check if the external device or circuit connection is safe Before checking or maintenance if the DC side and AC side is power down just now it is necessary to wait for 5 minutes to ensure the inner device is completely discharged and then the operation can be performed The surface temperature of the inverter may re...

Page 11: ...ed at the installation site Beware of electrical voltage The product operates at high voltages WEEE designation Do not dispose of the product together with the household waste but in accordance with the disposal regulations for electronic waste applicable at the installation site Observe the documentation CE marking The product complies with the requirements of the applicable EU directives 1 1 3 P...

Page 12: ... static wrist strap before touching sensitive components and the other end is well grounded 1 1 5 Grounding Requirements High leakage risk The inverter must be grounded before wiring The grounding terminal must be connected to ground or there will be the risk of electric shock when touching the inverter When installing the inverter must be grounded first When dismantling the grounding wire must be...

Page 13: ...man injury or device damage 1 1 8 Electrical Connection Electrical connection must be performed according to the description in the user manual and the electrical schematic diagram The configuration of PV string grid level grid frequency etc must meet the technical requirements of inverter Grid tied generation should be allowed by the local power supply department and the related operation should ...

Page 14: ...tery Do not damage the battery pack in such ways as dropping deforming impacting cutting or penetrating with a sharp object It may cause a leakage of electrolyte or fire Do not expose battery to open flame 1 2 2 Response to Emergency Situations The battery pack comprises multiple batteries that are designed to prevent hazards resulting from failures However We cannot guarantee their absolute safet...

Page 15: ...ctive ways to deal with accidents On land Place damaged battery into a segregated place and call local fire department or service engineer In water Stay out of the water and don t touch anything if any part of the battery inverter or wiring is submerged Do not use submerged battery again and contact the service engineer 1 3 Requirements for Operator The operation and wiring for inverter should be ...

Page 16: ...et the requirement the guarantee time may be influenced The used environment may influence the service life and reliability of the inverter So please avoid using the inverter in the following environment for a long time The place where beyond the specification operating temperature 30 60 relative humidity 0 95 The place where has vibration or easy impacted The place where has dust corrosive materi...

Page 17: ... charge and discharge are use DC DC circuit Charge and discharge are share a main circuit for two way flow of energy DC ACcircuit work as inverter when grid tied and off grid or work as rectifier when mains reverse charge the battery Inverter and rectifier are share a DC AC circuitfor two way flow of energy It is suitable for home and commercial roof PV generation system and distributed PV generat...

Page 18: ...el Meaning Inverter Figure2 2 Model meaningof the inverter Battery Figure2 3 Model meaning of the battery 2 1 2 Features Investable Better PV utilization Faster chargingability Higher battery efficiency Intelligent User friendly interface Intelligent monitoring Smart power grids adaptability ...

Page 19: ... 50 5 the battery charging power is determined by PV power supply power Self production mode When the energy generated by PV array is sufficient PV array will supply power for load in advance the remaining energy will charge battery If there still has remaining energy it will be supplied for grid connection generation Energy shift scheduling mode User can set the charging time and discharging time...

Page 20: ...n the peak period set to self production mode in the valley period set to backup mode in the other period the battery power is 0 and the PV array will supply power for grid if it still have energy 2 2 Appearance and Structure The appearance of the inverter and battery are as shown in Figure2 4 and Figure2 5 Figure2 4 Appearance of the inverter Figure2 5 Appearance of the battery ...

Page 21: ...K Series User Manual 2Overview 13 2 2 1 LED Signals Inverter Figure2 6 Inverter LED Signals Table2 1 Illustration of the inverter LED Status Illustration OFF Standby Red On fault Blue On The system works normally Flicker 1s alarm Flicker 3s standby ...

Page 22: ...SSi 3600 6000W 580VK Series User Manual 14 Battery Figure2 7 Battery LED Signals Table2 2 Illustration of the battery LED Status LED display Illustration Blue The battery capacity is 25 The battery capacity is 50 The battery capacity is 75 ...

Page 23: ...e see Table6 2 2 2 2 External Terminal Illustration The external terminals are all located at the left side of the inverter including PV input AC output communication port and DC switch etc as shown inFigure2 8 Figure2 8 Inverter terminals location Table2 3 Inverter terminals illustration NO Mark Illustration Remarks DC SWITCH DC switch Optional PV DC input terminal ...

Page 24: ...ve parallel function BMS connect to COM port of battery to communicate with battery DRM Inverter demand response modes Meter monitor the energy used BAT DC input terminal It is used to connect with battery Explosion proof valve Grounding port External grounding port Grid AC output terminal It is used to connect with grid Backup AC output terminal It is used to connect with load Battery terminals i...

Page 25: ...hown in the ofFigure2 8 is the connection switch of inverter and PV array When the inverter works normally the DC switch must be ON During installation and wiring the DC switch must be OFF Before maintenance the DC switch must be OFF for 5 minutes and measure the voltage of DC busbar by multimeter only when the voltage less than 10V the maintenance can be done When maintenance or wiring the DC swi...

Page 26: ...2Overview PV Energy Storage Inverter PSSi 3600 6000W 580VK Series User Manual 18 Figure2 10 DC coupled systems Figure2 11 AC coupled systems Figure2 12 hybrid coupled systems ...

Page 27: ...ion 19 3 Installation This chapter introduces the installation of the device including installation process installation preparation transportation and unpacking installation procedure electrical connection and checking etc 3 1 Installation Process Figure3 1 Installation process ...

Page 28: ...3Installation PV Energy Storage Inverter PSSi 3600 6000W 580VK Series User Manual 20 3 2 Installation Preparation 3 2 1 Tools Tools The installation tools must be insulated to avoid electric shock ...

Page 29: ...mperature will rise quickly so do not install the inverter under directly sunshine 2 It is suggested to install the inverter under shade as shown in Figure3 2 to max the inverter lifespan and efficiency 3 For easy viewing and operating the inverter please consider the visibility of the indicators and LCD during installation Figure3 2 Recommended installation site 3 2 3 Installation Space Keep at l...

Page 30: ... PSSi 3600 6000W 580VK Series User Manual 22 Figure3 3 Installation space unit mm 3 2 4 Installation Way Figure3 4 Installation way 3 3 Transportation and Unpacking 3 3 1 Transportation The device should be transported by trained professional ...

Page 31: ... been tested and checked strictly but it still may be damaged during transporting so please check it carefully Inspect the device s appearance if any shipping damage is found report it to the carrier and your local dealer immediately Check if the types of the accessories are complete and correct If there is any discrepancy take notes and contact the distributor immediately Figure3 5 Packing list 1...

Page 32: ...e battery pack is heavy There is risk of injury if the battery pack is lifted incorrectly or dropped while being transported or when attaching it to or removing it from the wall bracket 3 4 1 Single Battery Installation Step 1 Lift the battery pack using the handles at the two sides place it to assigned site Do not put the battery pack upside down on the ground Figure3 6 Lift the battery pack Step...

Page 33: ...3 Place the battery positioning paper against the wall and the bottom against the floor and mark the positions of the two drill holes as shown in Figure3 8 Figure3 8 Mark the battery drilling position Step 4 Drill 2 holes on the wall with drill Φ10 insert 2 screw anchors into the drill holes as shown in Figure3 9 ...

Page 34: ...rt the screw anchors Step 5 Attach the battery wall bracket to the wall using the screws with the tool of hexagon sleeve as shown in Figure3 10 Figure3 10 Install the wall bracket Step 6 Install the cardboard limit board on the top of the back of the battery pack with screw M5 as shown in Figure3 11 ...

Page 35: ... 3Installation 27 Figure3 11 Install the cardboard limit board Step 7 Place the battery against the wall align the holes at the battery side to the screw holes of the wall bracket Step 8 Tighten the wall bracket and the battery pack with screw M5 as shown in Figure3 12 ...

Page 36: ...tion site is uneven please use floor gaskets to level at the bottom of the battery pack End 3 4 2 More Batteries Installation You can install extra batteries up to 4 batteries in a system Please install extra batteries one by one also batteries can be stacked up to two batteries per column it is forbidden to stack 3 batteries from top to bottom ...

Page 37: ...en the batteries about 300mm Figure3 13 Distance between the batteries Stack installation Step 1 After install the single battery then lock the screw M6 on top of the below battery pack as shown in Figure3 14 Figure3 14 Lock the screw on top Step 2 Place the battery positioning paper against the wall and the bottom with notch against the below battery pack Repeat 3 4 1 Step 1 3 4 1 Step 8 ...

Page 38: ...ter PSSi 3600 6000W 580VK Series User Manual 30 Figure3 15 Place the battery positioning paper Step 3 The bottom limit holes of the upper battery pack should match the screw heads on the top of the below battery pack as shown in Figure3 16 ...

Page 39: ...PV Energy Storage Inverter PSSi 3600 6000W 580VK Series User Manual 3Installation 31 Figure3 16 Install the upper battery ...

Page 40: ...unting more batteries End 3 4 3 Inverter Installation Step 1 Align the bottom of the inverter s positioning paper with the notch of the battery top mark the positions of the drill holes on the paper plate Figure3 18 Place the inverter positioning paper Figure3 19 Mark the inverter drilling position ...

Page 41: ...nchors into the drill holes Figure3 20 Insert the screw anchors Step 3 Attach the wall bracket to the wall using the screws with the tool of hexagon sleeve as shown in Figure3 21 Figure3 21 Install expansion plugs Step 4 Hold the inverter using the handles at two sides attach the inverter onto the wall bracket tilted slightly downwards Step 5 Tighten the wall bracket and the inverter with screw M6...

Page 42: ...Manual 34 Figure3 22 Tighten theinverter End 3 5 Electrical Connection Figure3 23 Electrical Connection 3 5 1 Wire Requirement The wiring is at the left side of the inverter as shown in Figure2 8and Table2 3 The corresponding recommended wire specification as shown in Table3 1 ...

Page 43: ...cable in the industry recommended type Cat5e UTP UV resistant for outdoor use 0 12 0 2 mm2 AWG26 AWG24 N A Delivered with the battery pack 3 1 Signal cable Standard network cable in the industry recommended type Cat5e FTP UV resistant for outdoor use 0 12 0 2mm2 AWG26 AWG24 N A Delivered with the inverter 4 PV power cable Standard PV cable in the industry recommended type PV1 F 4 mm2 5 5 9 mm Purc...

Page 44: ...ngle core outdoor copper cable 4 10 mm2 N A Purchased by the installer 1 For CT communication connection with inverter 2 For CAN RS485 LAN Meter DRM communication connection with inverter 3 For AUX communication connection with inverter 3 5 2 External Grounding Connection The external grounding terminal is as shown in the 7 ofFigure2 8 The external grounding wire cannot replace the PE wire of AC o...

Page 45: ...al grounding terminal as shown in Figure3 25 Figure3 25 External grounding wire connection End 3 5 3 DC Input PV Connection When installation it must use the equipped DC terminals to avoid inverter damage It is recommended to use independent switch for each PV input and before connecting the switches must be off We suggest to use the special DC switch rated voltage is 600V rated current is more th...

Page 46: ...s Step 1 Strip the insulation layer ofpositive wire and negative wire for about 7mm as shown in Figure3 26 Figure3 26 Stripping diagram of DC input unit mm It is recommended to use red wire as the positive wire use black wire as negative wire to avoid wrong connection If using the wires of other colour please confirm the corresponding connection relationship Step 2 Unscrew the lock nut of positive...

Page 47: ...rusts respectively as shown in Figure3 29 Figure3 29 Tighten the sealing nuts Step 5 Measure the voltage and check if the positive and negative is connected properly and if the voltage within the input range of the inverter Step 6 Insert the positive connector and negative connector to the PV and PV terminals as shown in Figure3 31 and tighten them If there has a click sound it means that the conn...

Page 48: ...tallation PV Energy Storage Inverter PSSi 3600 6000W 580VK Series User Manual 40 Figure3 30 Connect the PV connector End 3 5 4 Battery Connection Battery power connection Figure3 31 Connect the BATconnector ...

Page 49: ...80VK Series User Manual 3Installation 41 Battery pack expansion Step 1 Connect the power cables and BMS communication from battery 2 to battery 1 Figure3 32 Install extra batteriesone by one without stack Figure3 33 Batteries installed with stack ...

Page 50: ...dden to connect with load between inverter and AC switch To ensure the inverter can be disconnected with load safely we suggest equipping independent dipolar switch for each inverter to protect the inverter Table3 2 RecommendedAC switch specification Model AC input specification GRID AC output specification BACKUP PSSi3600W 580VK 35A 18A PSSi5000W 580VK 50A 25A PSSi6000W 580VK 60A 30A ...

Page 51: ...ong connection If using the wires of other color please confirm the corresponding connection relationship Step 3 Insert the AC wire into the equipped90 terminal and crimp them by crimping tool as shown inFigure3 35 Figure3 35 Stripping diagram of external AC wire unit mm It is recommended to use brown or red wire as the live wire use blue or white wire as neutral wire and use yellow green wire as ...

Page 52: ...p 5 Insert the terminals with different color conductors to the holes of the respective polarity and tighten them one by one using the torque of 2 Nm with tool of crossrecessed screwdriver Figure3 36 Insert the terminals Step 6 Place the AC connection cover against the inverter housing and tighten them tighten the pressure caps of the two cable glands by hand Figure3 37 Place the AC connection ...

Page 53: ...ntion to the gap on the AC connector and make it align the heave on the GRID port avoid damaging the connector End 3 5 6 WIFI Connection If the inverter is equipped with WIFI insert it to the WIFI port as shown in Figure3 38 to monitor on the internet The monitor way is as shown inFigure3 38 Figure3 38 WIFI communication connection ...

Page 54: ... to set For the use of WIFI please see the built in user manual in the packaging of WIFI 3 5 7 Communication Port Connection Optional COM port can set to DRM and RS485 communication port they all adopt RJ45 plug to connect The pin definition of RJ45 plug is as shown in Figure3 41 Figure3 40 Meter pin definition of inverter s COM port ...

Page 55: ...J45 plug must be short connected together RS485 communication port RS485 communication port is used to communicate with smart meter to achieve anti countercurrent The connection between smart meter and inverter and grid is as shown in 错误 错误 错误 错误 不能识别的开关参 不能识别的开关参 不能识别的开关参 不能识别的开关参 数 数 数 数 Figure3 42 Connection diagram between communication smart meter and inverter and grid When using the anti cou...

Page 56: ...verter and phase L of grid input N Connect to phase N of GRID port in the inverter and phase N of grid input I Connect to I port of current transformer in the meter I Connect to I port of current transformer in the meter 5 RS485 A Connect to RJ45 s pin6 of COM port in the inverter 6 RS485 B Connect to RJ45 s pin5 of COM port in the inverter The setting of the smart meter address is as shown in Fig...

Page 57: ...ation 49 Figure3 44 Insert the communication port Step 2 lock the screw M4 on wiring cover plate as shown in Figure3 45 Figure3 45 Tighten the wiring cover plate Step 3 If the left and right sides of the inverter and battery are slightly uneven the gasket can be used to correct ...

Page 58: ...nual 50 Figure3 46 Pad the gasket End 3 6 Check the Installation After installation check the following items Check if the connection of DC input AC output and communication wire are right Check if the inverter is installed firmly Check if all the screws of wiring are tightened ...

Page 59: ...he following website to download the APP and do WIFI configuration Download APP APPSTORE https apps apple com cn app wisesolar plus id1510470362 GOOGLE PLAY https play google com store apps details id com kehua wisesolarpro WIFI configuration Operation guide https energy kehua com quickStart Step 2 After registering and logging in you can view the main page as shown in Figure4 1 ...

Page 60: ...Series User Manual 52 Figure4 1 Home interface Step 3 Click the plant to enter the Plant details interface as shown in Figure4 2 Figure4 2 Plant details interface Step 4 After that click the device list button to enter the device list interface as shown in Figure4 3 ...

Page 61: ...e Inverter PSSi 3600 6000W 580VK Series User Manual 4APP Operation 53 Figure4 3 Device list 4 2 Inverter Information Query Step 1 After performing the above steps click corresponding SN to view the inverter information ...

Page 62: ...VK Series User Manual 54 Figure4 4 Inverter information interface Step 2 Pull down the interface and click the More button to see more information such as PV information BAT information INV information and Grid information Figure4 5 Inverter information interface ...

Page 63: ...nning Information PV information In the PV information item you can view PV voltage PV current and PV power etc as shown in Figure4 6 Figure4 6 PV information Battery Information In the battery information item you can view battery voltage battery current battery power etc as shown in Figure4 7 ...

Page 64: ...Inverter PSSi 3600 6000W 580VK Series User Manual 56 Figure4 7 Battery information Inverter information In the inverter information item you can view total grid tied energy grid current grid side load voltage etc as shown in Figure4 8 ...

Page 65: ...PSSi 3600 6000W 580VK Series User Manual 4APP Operation 57 Figure4 8 Inverter information Grid information In the running information item you can view load voltage load current grid tied apparent power etc as shown in Figure4 9 ...

Page 66: ...y Storage Inverter PSSi 3600 6000W 580VK Series User Manual 58 Figure4 9 Grid information 4 2 2 Status Information In the status information item you can view battery information and device information as shown in Figure4 10 ...

Page 67: ...PV Energy Storage Inverter PSSi 3600 6000W 580VK Series User Manual 4APP Operation 59 Figure4 10 Status information ...

Page 68: ...e control interface as shown inFigure4 11 Figure4 11 Inverter information The control interface contains basic parameter setting system setting battery related setting grid related setting charge and discharge setting peak period setting and external control period setting Basic parameter setting Basic parameter setting contains ON OFF setting mode setting BMS communication setting ...

Page 69: ...ergy Storage Inverter PSSi 3600 6000W 580VK Series User Manual 4APP Operation 61 Figure4 12 Basic parameter setting System setting In the system setting item you can set system time Figure4 13 System setting ...

Page 70: ...tery related setting In the battery related setting item you can set battery charge and discharge power Figure4 14 Battery related setting Grid related setting In the grid related setting item you can set grid mode including P V mode Q V mode SPH mode and schedule mode As shown inFigure4 15 ...

Page 71: ...PV Energy Storage Inverter PSSi 3600 6000W 580VK Series User Manual 4APP Operation 63 Figure4 15 Grid related setting Charge and discharge setting Figure4 16 Charge and discharge ...

Page 72: ...Operation PV Energy Storage Inverter PSSi 3600 6000W 580VK Series User Manual 64 Peak period setting Figure4 17 Peak period setting External control period setting Figure4 18 External control period setting ...

Page 73: ...r you should set the inverter function via APP Step 4 When the DC and AC supply power normally the inverter will prepare to start At first the inverter will check the inner parameters and AC grid parameters if they are in the normal range 60s later the inverter will check the insulation impedance Step 5 About 60s the inverter will generate power normally LED id always on Step 6 working status can ...

Page 74: ...e temperature of some parts on the inverter is too high and may cause scald injury After shut down the inverter and wait until it cooling down then do the maintenance and clean Do not clean the inverter with any solvent abrasive material or corrosive material 6 2 Troubleshooting The inverter is designed on the basis of the grid connected operation standards and meets the requirements of safety and...

Page 75: ... may be caused by wet weather 2 Use a multimeter to test the impedance of the ground to the housing If the impedance is not close to 0 confirm that there is a connection problem between the ground wire and the housing 3 Test the impedance of ground to PV PV BAT BAT with a multimeter If the impedance is less than 25K ohms check whether the connection of each port is correct 4 Confirm to install the...

Page 76: ... customer service Inner Over temperature Ambient temperature is too high 1 Try to lower the ambient temperature 2 Make sure that the inverter is installed according to the manual and there is no shelter around the inverter 3 After the inverter is powered off and waiting for 30 minutes then restart it If the fault still exists contact service Inner communication fault DSP Inner communication abnorm...

Page 77: ...V2 voltage to see if it is exceeds 585V if exceed reduce the PV array quantity PV2hardwareover current PV2 hardware current exceed allow value 1 Try to lower PV power 2 Restart the inverter to see if the fault still exists If it still exists contact customer service MPPT Over temperature 1 Try to lower the ambient temperature 2 Make sure that the inverter is installed according to the manual and t...

Page 78: ... still exists contact service Battery over current Battery charge discharge current detected on software exceeds allow value 1 Try to reduce the BAT power 2 Restart the inverter to see if the fault still exists If it still exists contact customer service BMS communication fault Abnormal communication with BMS Check whether communication wire between BMS and inverter is loosed Battery inner fault S...

Page 79: ...r to see if the fault still exists If it still exists contact service Inverter current over current Inverter current detected on software exceeds the allowable value 1 Check whether the off grid output terminal is overloaded short circuited or has impact load 2 Restart the inverter to see if the fault still exists If it still exists contact service Inverter current DC component abnormal When grid ...

Page 80: ...Grid under frequency Grid frequency exceeds allow range 1 Check whether grid abnormal 2 check whether grid wiring abnormal 3 Restart the inverter to see if the fault still exists If it still exists contact service Grid tied phase lock abnormal Phase lock abnormal 1 Check whether grid abnormal 2 check whether grid wiring abnormal 3 Restart the inverter to see if the fault still exists If it still e...

Page 81: ...s If it still exists contact service Fan fault alarm Fan abnormal 1 Check whether the fan is blocked 2 Restart the inverter to see if the fault still exists If it still exists contact service Battery inner alarm Alarm instruction from BMS Check code position question from BMS on APP Heat sink over temperature alarm Temperature is too high to reach the rate drop point 1 Check whether the environmen...

Page 82: ... after exchanging two communication wires Heat sink sensor abnormal Heat sink sampling is less than 39 Check the temperature after the product is operating for a while if the temperature is abnormal please contact manufacturers Table6 2 Battery Error Description LED Indictor Error Code LED display Description Troubleshooting Red LEDs flash once every 1S Error 01 Hardware error Wait for automated r...

Page 83: ... Troubleshooting Error 05 Hardware error Error 06 Circuit switch open Switch on circuit switch afterpowering off the battery Error 08 LMU disconnect slave Reconnect the BMScommunication cable Error 09 SN missing Call for service Error 10 LMU disconnect master Reconnect the BMScommunication cable Error 11 Software version inconsistent Call for service ...

Page 84: ...oblem is not resolved call for service Error 15 Total voltage fault Restart battery and in case the problem is not resolved call for service If the inverter has any alarm information mentioned in Table6 1 please shut down the inverter refer to 5 2 Shutdown 5 minutes later restart the inverter refer to5 1 Startup If the alarm status is not removed please contact our local dealer or service centre B...

Page 85: ...al 6Maintenance and Troubleshooting 77 4 Problem description that is the alarm information displayed on the display screen and the status of indicators and other information obtained from information menu refer to 4 3 3 Record Query 5 Your detail contact information ...

Page 86: ...arry the devicewith the objects that is inflammable explosive or corrosive DO NOT put the device in the open air while midway transshipment Leaching or mechanical damage by rain snow or liquid objects is prohibited 7 3 Storage During storage place the device strictly according to the direction that showed on the carton Keep at least 20cm from the bottom of the carton to floor and keep at least 50c...

Page 87: ...PV Energy Storage Inverter PSSi 3600 6000W 580VK Series User Manual 7Package Transportation and Storage 79 ...

Page 88: ...x input power W 5400 7500 9000 Vmax PV Vdc 580 MPPT voltage range Vdc 100 550 Isc PV Adc 2 9 2 13 3 2 15 Full load MPPT voltage range Vdc 300 450 300 450 300 450 Startup voltage Vdc 100 No of MPPTs 2 2 2 Strings per MPPT 1 1 1 1 1 1 Max input current A dc 18 75 18 75 18 75 Maximum inverter backfeed current to Array A 0 0 0 Gridinput Rated input power W 7200 10000 12000 Max apparent power VA 7200 1...

Page 89: ...e Hz 45 0 53 0 Power factor rated power 0 99 Power factor adjusting range 0 8 ahead 0 8 lag 0 8 rated power THDi 3 rated power 5 load is 50 rated power Backupoutput Rated output power W 3600 5000 6000 Max apparent power VA 3600 5000 6000 Rated voltage Vac 220 Rated output current Aac 15 6 21 7 26 2 Max continuous output current Aac 15 6 21 7 26 2 Maximum output over current protection Aac 23 4 32 ...

Page 90: ...N505 49 CEI 0 21 CE Basic parameter Size W H D mm 580 280 230 Weight kg 16 3Kg Installation Wall mounting Insulation No transformer Degree of protection IP65 Self consumption at night 10W Operating temperature range INV 30 60 If the temperature higher than 45 or lower than 25 the inverter needs to decrease rated power to use BAT 10 50 If the temperature higher than 45 or lower than 10 the inverter...

Page 91: ...erminal MC4 max 10 mm the function Whole machine Update online Specifications are subject to change without prior notice A 2 Technical Specifications of Battery Model Item BAT input Max input voltage V dc 450 Input voltage range V dc 85 450 voltage range with full load V dc 167 400 Max charge current A dc 32 Max discharge current A dc 32 BAT pack Capacity 8 2 8 2 32 8 kwh Voltage range 244 288Vdc ...

Page 92: ... 10 50 If the temperature higher than 45 or lower than 10 the inverter needs to decrease rated power to use Operating humidity range 0 95 Cooling Natural Maximum operating altitude 3000m 3000m derating Noise emission typical 25db A 1m Inverter design Transformerless Display LED indicator Communication RS485 WIFI DRM Australia AC terminal Grid max 10mm Back up max 6mm PV DC terminal MC4 max 6 mm BA...

Page 93: ...al B Acronyms and Abbreviations 85 B Acronyms and Abbreviations A AC Alternating Current C CE ConformiteEuropeenne D DC Direct Current DSP Digital Signal Processor I IEC International Electrotechnical Commission L LCD Liquid Crystal Display LED Light emitting Diode M ...

Page 94: ... PV Energy Storage Inverter PSSi 3600 6000W 580VK Series User Manual 86 MPPT Maximum Power Point Tracking P PE Protective Earthing PV Photovoltaic R RS485 Recommend Standard485 T THDi Total Distortion of the input current waveform ...

Page 95: ......

Reviews: