22
d.
Check to make sure the RS-485 communication wires are properly connected. Make sure the
data conductors are not swapped. Measure the DC Voltage across D+ and D- at both the
monitoring enclosure and at the data terminals of the remote device. If the measurement is
0 DC you have a short in the data wires. If the difference between the two measurements is
greater than 3 DC then you may have an open circuit.
e.
If all of the previous steps do not help this issue contact Power-One Technical Support.
5.2 How to Contact Power-One Technical Support
For most efficient technical support please e-mail Technical Support at service.us@power-
one.com or call us at +1 877-261-1374. When requesting technical support, please provide the
following information:
a.
Model #.
b.
Unit serial number.
c.
Site/project name.
d.
Problem description.
Be prepared to describe the problem you are experiencing including specific details of the
application, installation, and any additional pertinent information.
In the event that the equipment needs to be returned to the factory for any reason, please call
to obtain an RMA# (Return Material Authorization). Do not return items without an RMA#
displayed on the outside of the package.
If you require an advance replacement to be shipped before the RMA unit has been received by
Power-One, you will need to submit a valid purchase order for the replacement unit,
referencing the RMA# on the P.O. When we receive the faulty unit, we will credit the cost of the
replacement, if it is covered by the warranty.
Include a written statement describing the problems.
Send the package with shipping prepaid to our factory address. Insure your shipment. Our
warranty does not cover damage incurred during transit.
6
Aurora Logger Specifications
6.1 Data Logger / Internet Gateway Specifications
Ethernet Network Connection
a.
Primary Physical network connection on 10BaseT Ethernet or 100BaseTX Fast Ethernet
networks using RJ45 twisted pair cable. (Port name - Eth 0)
b.
Secondary Physical network connection on 10BaseT Ethernet or 100BaseTX Fast Ethernet,
but limited in speed to 12 MBit/s since it is connected through an internal USB port. (Port