5.2.2
Internally logged data
Aurora stores internally the following data:
Lifetime counter of grid connection time
Lifetime counter of energy transferred to the grid
Energy transferred to the grid every 10 seconds for the last 8640 periods of 10
seconds (which on average cover more than 2 days logged data)
Partial counter of grid connection time (counter start time can be reset using
the AURORA Communicator software)
Partial counter of energy (uses the same start time of the partial time counter)
Last 100 fault conditions with error code and time stamp
Last 100 changes to grid connection parameters with parameter code and new
value.
The first two types of data are displayed on the LCD and through the RS-485
interface, while all other data can be displayed only through RS-485 interface