Before installation, read the following
instructions carefully. Failure to follow
instruction and Safety information could cause
serious bodily injury, death and/or property
damage. Each Power-Flo pump is individually
factory tested to insure proper performance.
Closely following these instructions will
eliminate potential operating problems,
assuring years of trouble-free service.
Installation, wiring,
and junction
connections must be in accordance with
the National Electric Code and all applicable
state and local codes. Requirements may vary
depending on usage and location.
Installation and
servicing is to be
conducted by qualified personnel only.
This pump is
not
intended for use in
swimming pools, spa areas or water
installations where human contact
with pumped fluid.
Risk of electric shock.
To reduce risk of
electric shock, always disconnect
pump from power source before
handling.
Lock out power & tag.
In the event the
retaining screws have
been pulled out of the
housing,
DO NOT
replace them. Use
of any other screw may short out
the stator windings, creating a risk of
electrical shock.
The addition of
petroleum based fluids
or certain chemical additives to the system
voids the warranty.
Pumps build up heat
and pressure during
operation. Allow time
for pumps to cool
before handling or
servicing.
Features:
These Power-Flo Circulator Pumps are
designed to be installed in residential potable
domestic hot water systems to provide
recirculation (in a RETRO-FIT application where
NO dedicated recirculation pipe has been
installed) of domestic hot water resulting in
“instant” hot water at fixtures throughout the
house. This unit is designed to install
ON TOP
OF THE WATER HEATER
on hot water supply
side and will connect directly onto the supply
nipple on top of the heater. This pump will
come equipped with a standard terminal box
to allow for connection to direct 115 V AC
AND will come with a 6 Ft. long soft jacketed 3
prong electric cord and strain relief connection
for “outlet plug in” installations.
NOTE: This
unit MUST be installed with the Power-Flo
Pumps “Retro-Fit Valve” (PFRFV)
MOTOR:
2-pole, 3600rpm, single phase,
PSC with Thermal protection
LIQUID TEMPERATURE:
32°F - 230°F
MAX. SYSTEM PRESSURE:
145 PSI
INSULATION:
Class H
VOLUTE:
Stainless Steel
CONNECTION:
3/4” M x 3/4” FNPT
POWER CORD:
6 Foot with 3 prong plug
ACCESSORIES:
PFFP- Fitting Pack,
PFDT - Digital Timer, PFSOA - Snap-On
Aquastat, PFRFV - Retro-Fit Valve
WARRANTY:
3 year
Receiving Inspection
Upon receiving the pump, it should be
inspected for damage or shortages. If
damage has occurred, file a claim
immediately with the company that delivered
the pump. Care should be taken to ensure
the pump is
NOT
dropped or mishandled,
dropping will damage the pump. If the
manual is removed from the packaging, do
not lose or misplace.
PFWRC67S1U
Wet Rotor Circulator Pumps
WARNING:
CANCER AND REPRODUCTIVE HARM-
WWW.P65WARNINGS.CA.GOV