Before installation, read the following 
instructions carefully. Failure to follow 
instruction and Safety information could 
cause serious bodily injury, death and/or 
property damage. Each Power-Flo pump is 
individually factory tested to insure proper 
performance. Closely following these 
instructions will eliminate potential operating 
problems, assuring years of trouble-free 
service.

IMPORTANT - Power-Flo Pumps and 
Systems is not responsible for losses, injury 
or death resulting from failure to observe 
these safety precautions, misuse, abuse or 
misapplication of pumps or equipment.

  Do not pump 

  flammable or explosive 

  liquids such as oil,  

  gasoline, kerosene, 

  ethanol, etc. Do not 

  use in the presence 

of  flammable or explosive vapors. Using 

this pump with or near flammable liquids 

can cause an explosion or fire, resulting in 

property damage, serious personal injury, 

and/or death.

  ALWAYS disconnect
  the power to the pump 

before servicing.

 Release all pressure and
 drain all water from the 

system before servicing any component.

  Do not touch the 
  motor housing during 

  operation. The motor is designed 
  to operate at high temperatures. 
  Do not disassemble the motor 
  housing.

  Do not handle the 
  pump or pump motor 

  with wet hands or when standing 
  on a wet or damp surface, or in 
  water before disconnect the power.

  Secure the discharge 
  line before starting the 

pump. An unsecured discharge line will whip, 
possibly causing personal injury, and/or 
property damage.

  Extension cords may 
  not deliver sufficient 

  voltage to the pump motor. 
  Extension cords present a life 
  threatening safety hazard if 

the insulation becomes damaged or the 
connection ends fall into water. The use of 
an extension cord to power this pump is not 
permitted.

  Wear safety goggles at 
  all times  when 

working with pumps.

  These units are designed 

  for use on 115 volts 

(single phase), 60 Hz, and equipped with an 

approved 3-conductor cord and 3-prong 

grounded plug. Do not remove the ground 

pin under any circumstances. The 3-prong 

plug must be directly inserted into a 

properly installed and grounded 3-prong, 

grounding-type receptacle. Do not use this 

pump with a 2-prong wall outlet. Replace 

the 2-prong outlet with a properly grounded 

3-prong receptacle (a GFCI outlet) installed 

in accordance with the National Electrical 

Code and local codes and ordinances. All 

wiring should be performed by a qualified 
electrician.
 

 

 

  Protect the electrical
  cord from sharp 

objects, hot surfaces, oil, and chemicals. Avoid 

kinking the cord. Do not use damaged or 

worn cords.

  Failure to comply with 
  the instruction and 

designed operation of this unit may void the 

warranty. 

ATTEMPTING TO USE A DAMAGED 

PUMP

 can result in property damage, serious 

personal injury, and/or death.

  Ensure that the 
  electrical circuit to 

the pump is protected by a 15 Amp,  fuse or 
circuit breaker.

   Do not lift the pump 
   by the power cord.

  Know the pump and its 
  applications, 

limitations, and potential hazards.

IMPORTANT !

 - Secure the pump to a solid 

base. This will aid in keeping the pump in a 

vertical orientation. This is critical in keeping 

the pump operating at maximum efficiency. 

It will also help prevent the pump from 

clogging resulting in premature failure.

IMPORTANT !

 - Periodically inspect the pump 

and system components to ensure the pump 

suction screen is free of mud, sand, and 

debris. Disconnect the pump from the power 

supply before inspecting.

  Follow all local 
  electrical and safety

codes, along with the National Electrical Code 
(NEC). In addition, all Occupational Safety 
and Health Administration (OSHA) guidelines 
must be followed.

  The motor of this pump
  has a thermal protector 

that will trip if the motor becomes too hot. 

The protector will reset itself once the motor 

cools down and an acceptable temperature 

has been reached. The pump may start 

unexpectedly if it is plugged in.

  Ensure the electrical 
  power source is 

adequate for the requirements of the pump.

IMPORTANT ! 

- This pump is made of high-

strength, corrosion-resistant materials. It will 
provide trouble-free service for a long time 
when properly installed, maintained, and used. 
However, inadequate electrical power to the 
pump, dirt, or debris may cause the pump to 
fail. 

WARNING: 

CANCER AND REPRODUCTIVE HARM-

WWW.P65WARNINGS.CA.GOV

Summary of Contents for PFSWCPC50 Series

Page 1: ...877 24PUMPS www powerflopumps com ISP No PFSWC50 1 2021 OWNER S MANUAL Series PFSWCPC50 1 2 HP 3450 RPM 60 Hz Submersible Sewage Pump...

Page 2: ...uctor cord and 3 prong grounded plug Do not remove the ground pin under any circumstances The 3 prong plug must be directly inserted into a properly installed and grounded 3 prong grounding type recep...

Page 3: ...le Tethered Mechanical Normally Open N O Reinforced thermoplastic 115V SJOW 18AWG 2C 10 Ft cord w Piggy back plug On point 15 1 Off point 6 8 P N 10Ft PFTFS10D1810P1 WARRANTY 3 year MODEL HP Hz Volts...

Page 4: ...4 Power Flo Pumps Systems 877 24PUMPS www powerflopumps com PFSWCPC50Series Submersible Sewage Pumps Performance Dimensions Models PFSWCPC50181081T10...

Page 5: ...2 inch solids The pump is built with overload thermal protections and auto reset The pump is equipped with a 3 prong grounding type power cord and tethered float switch This pump operates automaticall...

Page 6: ...To protect against electrical shock the power cord is a three wire conductor and includes a 3 prong grounded plug Plug pump into a 3 wire grounded grounding type receptacle Connect pump according to...

Page 7: ...blow 2 The breaker is tripped 3 The plug is disconnected 4 The plug is corroded 5 Thermal overload 6 Clogged impeller 7 Motor failed 8 Float failed 9 Water level too low 10 Tangled switch 1 Replace t...

Page 8: ...ances including but not limited to the following sand gravel cement mud tar hydrocarbons hydrocarbon derivatives oil gasoline solvents etc or other abrasive or corrosive substances washtowelsorfeminin...

Reviews: