background image

Power-Flo Pumps & Systems • 877-24PUMPS • www.powerfl opumps.com

9

  Pressure builds up  extremely
  fast, increase   pressure by 

“TAPPING” air nozzle. Too much 
pressure will damage seal. 

DO 

NOT  exceed 10 P.S.I.

Seal Chamber 

- Set pump on its side with 

fi ll plug (30) downward, remove plug (30) 
and drain all oil from seal chamber. Apply 
pipe sealant to pressure gauge assembly 
and tighten into hole in intermediate 
coupling (5). Pressurize seal chamber to 
10 P.S.I. and check for leaks.

Oil Replacement: 
Motor Housing -

 Drain all oil (if not 

already done so) from motor housing 
and dispose of properly per Local and 
Environmental Standards. 

Set pump upright and refi ll with new 
cooling oil, see “Cooling Oil” chart. Fill to 
just above motor as an air space must 
remain in the top of the motor housing to 
compensate for oil expansion. Apply pipe 
thread compound to threads of pipe plug 
(30) then assemble to motor housing (8).

Seal Chamber -

 Drain all oil (if not already 

done so) from seal chamber and dispose 
of properly per Local and Environmental 
Standards. Place pump on its side with 
plug (30) upward, and refi ll with new oil, 
see “Cooling Oil” chart. Apply pipe thread 
compond to threads of pipe plug (30) and 
assemble to intermediate coupling (5).

 

DO NOT

 overfill oil. Overfilling 

 of housing with oil can create 

excessive and dangerous hydraulic
pressure which can destroy the
pump and create a hazard. 
Overfilling oil voids warranty.

Cooling Oil

Recommended Supplier/Grade

BP

Enerpar SE100

Conoco

Pale Paraffin 22

Mobile

D.T.E. Oil Light

Shell Canada

Transformer-10

Texaco

Diala-Oil-AX

 WARNING ! - Before any service 
 work is done, disconnect and  
 lock out electrical power to 
 pump.

Disassembly

Cutter - 

Lay pump on its side and remove 

the cutter retaining screw (29) and washer 
(28). A small amount of heat may be 
needed to loosen screw. 

DO NOT

 overheat. 

Wedge a fl at screwdriver between cutter 
and shredding ring and remove screw. 
With a hammer and punch, tap the cutter 
(27) counter-clockwise to remove.

 CAUTION ! - Cutter edges are 
 very SHARP. Cutter must be 
 removed before removing volute.

Volute - 

Remove hex nuts (25) and 

washers (9) from studs (26) and remove 
volute (23) and square ring (24) from 
pump.

Shredding Ring -

 To replace or reverse 

the shredding ring (20), remove allen 
screws (22) and lift throat (21) from volute 
(23) then press out using an arbor press.
The shredding ring (20) can be pressed 
out and reversed when cutting edges dull.

Impeller -

 Remove impeller (18) by 

turning counter-clockwise while holding 
the motor shaft stationary with a 
screwdriver.  

NOTE:

 Seal spring is relaxed 

with impeller removed, some oil may 
seep from seal cavity. 

Do Not

 store pump 

without impeller in place.

Outer Seal -

 Handle seal parts with care. 

Remove seal (34) spring and rotating 
member from shaft. Examine all seal 
parts. Inspect contact faces for signs of 
uneven wear tracks on stationary, chips 
and scratches on either seal face. 

DO NOT 

interchange seal components, replace 
the entire shaft seal (34).

Seal Plate -

 Remove cap screws (35) and 

washers (38) from seal plate (19). Remove 
seal plate (19) and square ring (24) from 
intermediate coupling (5). With fl at 
screwdriver, press out seal (34) stationary 
member. Inspect square ring (24) for cuts 
or abrasions.

Cable Assemblies -

 Remove Hex plugs 

(13B) and (14B), washers (13C) and (14C) 
and gromeents (13D) and (14D) from 
conduit box (11).

Motor -

 Remove pipe plug (30) and drain 

oil if not already done so. Position pump 
upright using blocks or pvc pipe to avoid 
resting pump on the shaft. Remove cap 
screws (15) and lockwashers (16) from 
cable box assembly (11) and slide conduit 
box up the cords until motor lead wires 
are exposed. Disconnect connectors (17) 
from motor leads wires to remove cable 
assemblies (13) and (14). Remove ground 
screw (31). Remove and inspect o-ring 
(12).

Remove cap screws (10) and lockwashers 
(9) from motor housing (8). Vertically lift 
motor housing (8) from intermediate 
coupling (5) along with square ring (7),  
replace if cut or damaged. Remove motor 
bolts and carefully remove stator housing 
from rotor. Remove retaining ring (2) from 
intermediate (5) and pull rotor out with 
bearing (3) and rotating member of inner 
seal.

Service

PFG 3, 5 & 7.5HP   

 

  

      

       

 

 Submersible Grinder Pumps

Summary of Contents for PFG3022

Page 1: ...om ISP No PFGrinder357 5 13 INSTALLATION SERVICE PARTS MANUAL Power Flo Pumps Systems 877 24PUMPS www powerflopumps com Series PFG3022 PFG3062 PFG3032 PFG3042 PFG5022 PFG5062 PFG5032 PFG5042 PFG7532 P...

Page 2: ...only Keep clear of suction and discharge openings Do not insert fingers in pump with power connected Always wear eye protection when working on pumps Do not wear loose clothing that may become entangl...

Page 3: ...il Lubricated LOWER BEARING Sleeve Oil Lubricated POWER CORD 30 ft Cord Pressure grommet for Sealing and Strain Relief MOTOR Oil Filled Squirrel Cage Induction Class F Insulation SINGLE PHASE Capacito...

Page 4: ...if a Power Flo control panel is not used see page 17 PFG 3 5 7 5HP Submersible Grinder Pumps Recommended Breaker Heater Sizes MODEL HP Hz Volts Ph Breaker Size Heater Size Voltage Relay Start Capacito...

Page 5: ...Power Flo Pumps Systems 877 24PUMPS www powerflopumps com 5 Performance PFG 3 5 7 5HP Submersible Grinder Pumps...

Page 6: ...Controls PFG series grinders require a separate approved pump control device or panel for automatic operation Be sure the electrical specification of the control selected properly match the electrical...

Page 7: ...minimum level of 10 inches above the basin floor Electrical Connections Power cable The power cable mounted to the pump must not be modified in any way except for shortening to a specific application...

Page 8: ...unit upright Remove pipe plug 30 from housing 8 With a flashlight visually inspect the oil in housing 8 to make sure it is clean and clear light amber in color and free from suspended particles Milky...

Page 9: ...ove CAUTION Cutter edges are very SHARP Cutter must be removedbeforeremovingvolute Volute Remove hex nuts 25 and washers 9 from studs 26 and remove volute 23 and square ring 24 from pump Shredding Rin...

Page 10: ...seal cavity in intermediate coupling 5 Lightly oil Do not use grease outer surface of stationary member Press seal s 4 stationary member firmly into intermediate coupling 5 using a seal tool or pipe...

Page 11: ...Green Black 1 7 Red 2 8 White 3 9 T4 T5 T6 Together FIGURE 4 THREE PHASE 460 VOLT AC Power Cable Motor Lead Number Green Ground Green Black 1 Red 2 White 3 T4 T7 Together T5 T8 Together T6 T9 Together...

Page 12: ...T Do not hammer on the seal pusher It will damage the seal face With seal guide tool over motor shaft Lightly oil Do not use grease guide shaft and inner surface of bellows on rotating seal With lappe...

Page 13: ...Power Flo Pumps Systems 877 24PUMPS www powerflopumps com 13 Typical Panel Wiring Schematic PFG 3 5 7 5HP Submersible Grinder Pumps Figure 6...

Page 14: ...UMPS www powerflopumps com 14 Figure 7 Repair Parts For Repair Part Please supply Model Number and MFG Date as shown on Name Plate and Part Description and Part Number as shown on Parts List PFG 3 5 7...

Page 15: ...UMPS www powerflopumps com 15 Figure 8 Repair Parts For Repair Part Please supply Model Number and MFG Date as shown on Name Plate and Part Description and Part Number as shown on Parts List PFG 3 5 7...

Page 16: ...10 4 SOW PF31030003 13B 1 Hex Plug PF30400903 13C 2 Friction ring PF91010055 13D 1 Grommet PF92010001 14 1 Moisture Temperture Sensor Cable 18 5 SOW 30Ft PF31030005 14B 1 Hex plug PF30400901 14C 2 Fr...

Page 17: ...l Bearing 6203ZZ PF070715 Repair Kits CUTTER KIT Includes Item numbers 20 27 28 29 PFGL CT 6 OVERHAUL KIT Includes Item numbers 2 3 4 6 7 20 24 27 28 29 34 PFGL OHK SEAL PROBE KIT Includes item number...

Page 18: ...Power Flo Pumps Systems 877 24PUMPS www powerflopumps com 18 Notes PFG 3 5 7 5HP Submersible Grinder Pumps...

Page 19: ...hole 10 Check rotation If power supply is three phase reverse any two of three power supply leads to ensure proper impeller rotation 11 Repair fixtures as required to eliminate leakage 12 Check pump t...

Page 20: ...that has not been installed operated or maintained in accordance with Manufacturer s installation instructions that has been exposed to outside substances including but not limited to the following sa...

Reviews: