4
Power-Flo Pumps & Systems • 877-24PUMPS • www.powerflopumps.com
Specifications
MODEL
HP VOLT/
PH
RPM
MTR
FRAME
FULL
LOAD
AMPS
LOCKED
ROTOR
AMPS
WINDING
RESISTANCE
(in ohms, for 1 coil)
NEMA
START
CODE
CORD
CORD
O.D.
PF4SCC4236
4.2
230/3
1150
100
12.8
63
2.45
G
4G1.5mm
2
(14/4, SO)
0.457
(0.57)
PF4SCC4246
4.2
460/3
1150
100
6.4
31.5
2.45
G
4G1.5mm
2
(14/4, SO)
0.457
(0.57)
PF4SCC4834
4.8
230/3
1750
100
14.4
80
1.21
H
4G1.5mm
2
(14/4, SO)
0.457
(0.57)
PF4SCC4844
4.8
460/3
1750
100
7.2
40
1.21
H
4G1.5mm
2
(14/4, SO)
0.457
(0.57)
Control cable sizes for all models is, 4G1.5mm
2
, 0.457 O.D. (14/3, SO, 0.53 O.D.)
NOTE: The use of a 4” Break Away Fitting is required with these pumps.
NOTE: A relay is required for use with Moisture Sensor, see page 25.
PF4SCC
Submersible Cutter Pumps