POWER ELECTRONICS
SD300
DESCRIPTION OF PROGRAMMING PARAMETERS
187
Screen Description
Default
value
Range
Function
Set on
RUN
CM.93
NAK frames
0
0 to 65535 Count the number frames received
with timeout.
YES
CM.94
[31]
Communications
update
N
NO
SI
This parameter enables sending the
current drive data configuration to the
communications card.
NO
CM.95
P2P
communication
selection
Disable
All
0 to 3
P2P communication allows sharing
input devices between different drives.
To enable it, RS485 communication
must be active.
This parameter allows defining which
devices will be master and which slave
in the P2P communication.
OPT. FUNCTION
0
Disable All
1
P2P Master
2
P2P Slave
3
M-KPD Ready
NO
CM.96
[32]
Digital output
selection
NO
000 to 111
When multi-function outputs are used,
a drive configured as P2P slave can
choose whether to use its own output
or the drive’s output.
OPT. FUNCTION
001
Analog output
010
Multi-function relay
100
Multi-function output
YES
[31] Only shown if an optional communications card has been connected.
[32] Displayed when AP.1 is set to 2 (Proc PID).
Summary of Contents for SD 300 Series
Page 1: ...SD300 GETTING STARTED MANUAL LOW VOLTAGE VARIABLE SPEED DRIVE ...
Page 2: ......
Page 3: ...Variable Speed Drive Getting Started Manual Edition February 2019 SD30IM01GI Rev G ...
Page 159: ...POWER ELECTRONICS SD300 DESCRIPTION OF PROGRAMMING PARAMETERS 157 Power off delay ...
Page 174: ...SD300 POWER ELECTRONICS 172 DESCRIPTION OF PROGRAMMING PARAMETERS TI configuration ...
Page 352: ......
Page 353: ......