3.9.1 PAMIO boxes and modules
Fig. 52: PAMIO superbus schematic
1
control unit
2
PA superbus connection
3
PAMIO box with two analog axes modules
4
PA superbus connection
5
termination plug
6
max. chain length (14 PAMIO boxes/30 m (98 ft))
A PAMIO box consists of its housing, the PA superbus input and
output connectors as well as two plug-in-slots for I/O modules. PAMIO
boxes can be snapped onto DIN rails and plugged into each other side
by side or connected through optional cables. The last box carries a
termination plug.
Limited cable length
The limits for the I/O system are 31 I/O modules (1 internal 4AXLX
module, 2 internal 2416EL modules plus a maximum of 14 PAMIO
boxes). The maximum cable length from the control unit to the last
PAMIO box cannot exceed 30 m (98 ft). This has to be considered as
a maximum global length when several PAMIO boxes are placed at
different locations and connected with interconnection cables.
I/O modules can be mounted where needed, without requiring bus
couplers. Each PAMIO module has its own watchdog timer for the PA
superbus, temperature and voltage monitoring as well as corre-
sponding LED displays on the front side.
Scope of delivery (control unit)
The PAMIO modules listed below are not included in the control unit's
basic scope of delivery. They can be ordered from Power Automation
(see
Chapter 9 “Service and return process” on page 119).
Basic Description
PA 8000 LW CNC control unit
Design and function
25.09.2015 | 80
Summary of Contents for PA 8000 LW Series
Page 1: ...PA 8000 LW CNC control unit Installation instructions...
Page 12: ...PA 8000 LW CNC control unit General information 25 09 2015 12...
Page 85: ...4 4 Dimension sheet PA 8000 LW CNC control unit Technical data 25 09 2015 85...
Page 86: ...Fig 54 dimension sheet PA 8000 LW CNC control unit Technical data 25 09 2015 86...
Page 123: ...Fig 67 RMA Form RMA Form PA 8000 LW CNC control unit Service and return process 25 09 2015 123...
Page 126: ...PA 8000 LW CNC control unit Dismounting and decommissioning 25 09 2015 126...
Page 130: ...PA 8000 LW CNC control unit Proof of change 25 09 2015 130...