- 2 -
0600-GB Saatmengenverstellung_8521
GB
54
Hydraulic Seed Rate Adjustment
It maybe advisable to adjust to maximum seed rate in connection
with the hydraulic coulter pressure adjustment.
To operate, switch the path valve to the appropriate setting (on the
coupling).
Settings „Normal“ and „Maximum Amount“:
„Normal Amount“ – calibrate as usual; star handle (
21/1
, page 10)
but set as limiter behind the lever (towards 0) – fasten tightly.
(Cylinder remains retracted.)
„Maximum Amount“ – Fully extend the cylinder, select „Max. Amount“
by moving cylinder – at (
54/1
) – and secure (
54/2
).
Re-calibrate.
Note:
Do not clamp down the transmission select lever!
Highest transmission setting for „Normal Amount“ = „100“ minus
required extra amount (cylinder path).
Emergency operation:
If the electronics fail the sowing quantity can be manually
adjusted
Take the following steps:
- Release connection between setting cylinder and adjusting
lever by removing screws (60)
- Unscrew star grip (61)
- Determine work setting (using seed table or from Power Control
Menu)
- Move lever (62) into calculated position and clamp tight using
star grip (61)
1) Optional extra
Electric sowing quantity adjustment
1)
SEED qUAnTiTY ADjUSTMEnT