- 48 -
0701_GB-ISoBUS-terminal_5543
GB
isobus - TerMinal
By pressing the “DIAG-->“ button for 12 secs
- Switching the diagnostic function off for all fault-
cancelled outputs in addition to the previously
blocked outputs
- symbol change-over from "
❏
" to "
✕
"
- is indicated through a short signal tone
By pressing the “DIAG-->“ button for 15 secs
- release of diagnostic function for all outputs (except
loading space lamp 2)
- substitute all "
✕
"
- is indicated by a long signal tone
The order of the matrix fields to the following
outputs
A1 - pick-up valve
A2 - Regulating rollers
A - Pivoting drawbar valve
A4 - Cross conveyor belt valve
A5 - Cutting mechanism valve
A6 - Tailgate valve
A7 - Scraper floor phase 2 valve
A8 - Trailing front axle valve
B1 - Forage top frame valve
B2 - Loading space lighting
B - Forage reagent distributor
B4 - Directional control valve (Y oder Y4)
B5 - Cross conveyor belt valve left
B6 - KRB-Proportional valve
Following symbols are shown
✓
... Output in order
✕
... Diagnostics switched off
❏
.. Diagnostic has responded and will be cancelled
With fault recognition
- alarm mask is superimposed
- alarm signal is audible
Diagnostic function can be switched off for each individual
channel.
A fault must be cancelled with the
“ACk” button
. A
cancelled fault will no longer be registered up to the next
job calculator new start.
Starting from
Start Menu
- Press
button 5
With that the
Diagnostic Menu
is reached
Note!
The alarms for the
power supply
cannot be
switched off.
Diagnostic menu