3.0
APPLIANCE OPERATION
8
Publication No. 5111813
3.3
Domestic Hot Water Mode
(Fig. 4)
1. Priority is given to the domestic hot water supply. A
demand at a tap or shower will override any central
heating requirement.
2. The flow of water will operate the DHW flow switch
which requests the 3 way valve to change position.
This will allow the pump to circulate the primary water
through the DHW plate heat exchanger and take the
stored water to give instant hot water.
3. The burner will light automatically and the
temperature of the domestic hot water is controlled by
the temperature sensor.
4. When the domestic hot water demand ceases the
burner will extinguish and the diverter valve will
remain in the domestic hot water mode, unless there
is a demand for central heating.
5. If there is no other demand the pre-heat function
will operate if switched on (see Section 3.2)
IMPORTANT:
When the selector switch is in the
‘0’ (Off) position the electrical supply to the boiler is
isolated. The boiler will not operate and the
integral timer (if fitted) will require resetting once
the selector switch is set to either Position (i) or
Position (ii).
3.4
Frost Protection Mode
1. The frost protection mode is integral to the
appliance and functions only with the selector switch
(Section 2.1) in the domestic hot water and central
heating position. If the system temperature falls below
5° C then the boiler will fire on its minimum setting
until a flow temperature of 30° C is reached. Further
protection can be incorporated by using a system
frost thermostat.
3.5
Pump Protection
1. With the selector switch (see Section 2.1) in either
the central heating or central heating and domestic
hot water position the pump will automatically operate
for 1 minute in every 24 hours to prevent sticking.
27
19
16
15
14
13
12
10
9
11
8
17
21
23
20 22
19
26
5
6
2
3
4
1
25
24
18
7
28
1
Primary Heat Exchanger
2
Burner
3
Ignition Electrode
4
Flame Sensing Electrode
5
Gas Valve
6
Pump
7
Automatic Air Vent
8
Plate Heat Exchanger
9
Flow Sensor with Filter
10 Pressure Relief Valve
11 Boiler Drain Point
12 Heating Return
13 Cold Water Inlet On/Off Valve and Filter
14 Gas Inlet
15 Domestic Hot Water Outlet
16 Heating Flow
17 Pressure Gauge
18 Hydraulic Pressure Sensor Microswitch
19 Automatic By-Pass
20 Hydraulic Pressure Sensor
21 Diverter Valve Assembly
22 Domestic Hot Water Flow Priority Assembly
23 Domestic Hot Water Flow Priority Microswitch
24 Safety Thermostat
25 Central Heating Temperature Sensor
26 Expansion Vessel & Pre-Heat Store
27 Domestic Hot Water Temperature Sensor
28 Secondary Heat Exchanger
Key
Fig. 4
Domestic Hot Water Mode