Model
Para‐
mount
30
Para‐
mount
40
Para‐
mount
50
Para‐
mount
60
Para‐
mount
80
Para‐
mount
95
Para‐
mount
115
Connection values
Natural gas E [H
UB
9,45 kWh/m³]
m³/h 0,59 -
3,2
0.95 -
4.0
1,06 -
5,30
1,48 -
6,10
2,22 -
8,10
2,12 -
10,10
2,65 -
12,20
Natural gas LL [H
UB
8,13 kWh/m³]
m³/h 0,69 -
3,7
1,11 -
4,7
1,23 -
6,20
1,72 -
7,10
2,58 -
9,50
2,46 -
11,70
3,08 -
14,10
Connection pressure for propane
mbar
min. 25 - max. 45
Propane [H
U
12,87
kWh/kg]
kg/h 0,44 -
2,33
0,70 -
2,95
0,93 -
3,89
1,09 -
4,51
1,63 -
5,98
2,33 -
7,38
2,72 -
8,94
Propane [H
U
24.64
kWh/m³]
m³/h 0,23 -
1,22
0,37 -
1,54
0,49 -
2,03
0,57 -
2,35
0,85 -
3,13
1,22 -
3,86
1,42 -
4,67
Electrical power consumption
Electrical connection
V/Hz
230 V / 50 Hz
Max. electr. power consumption
W
55
70
88
100
112
170
200
Heating mode
Protection
W
3
3
3
3
3
3
3
Dimensions
Weight of boiler
kg
53
53
61
61
72
84
84
Boiler water content
l
3,6
3,6
4,7
4,7
5,8
7,8
7,8
Height
mm
852
Width
mm
480
Depth
mm
407
407
447
447
542
570
570
Connections
Gas connection
3/4"
1"
Heating flow
1"
1
1
/
2
”
Heating return
1"
1
1
/
2
”
For more information, see
Power compensation for increasing the permissible flue gas piping
3.2.4
Tables of sensor values
Tab.5
Resistance values for outside temperature sensor ATF
Temperature [°C]
Resistance [Ω]
-20
8194
-15
6256
-10
4825
-5
3758
0
2954
5
2342
10
1872
15
1508
20
1224
25
1000
30
823
Tab.6
Resistance values for flow sensor KVF, drinking water sensor
TWF, return sensor KRF, Buffer sensor B41
Temperature [°C]
Resistance [Ω]
0
32555
5
25339
10
19873
3 Technical specifications
16
Paramount five 30 – 115
7703046 - 01 - 23072018