17
CONTROL CENTRE PROGRAM SEQUENCE
P
H
_
THL2
Z
P
H
_
THL2
Z
22
0
1
2
3
6
5
4
10 Hz
11 Bw
12 Hz+Bw
20
2
4
7
21
99
H
M
I-
Anzeige:
R
Phas
e
Heimlauf
T
L
O
T
N
B
Standby
ti
PH_TNB
tv
T
B
R
E
Betrieb
T
W
1
T
W
2
tv
z
ts
a
1
ts
a
2
tn
ts
a
T
N
N
ts
a
1
ts
a
2
ts
a
T
H
L
2
tn
PH_TLO
PH_TNN
P
H
_
S
T
A
N
D
B
Y
PH_
STARTVER
PH_
THL1_1
PH_TV
PH_TB
RE
PH_TW
1
PH_TW
2
PH_TV
Z
PH_
TSA2_1
PH_TI
PH_
MODU-
LATION
PH_
THL2_1
PH_TN_
1
PH_
TSA1_1
PH_
TSA2_2
PH_
TSA1_2
PH_
THL2_2
PH_TN_
2
PH_
STOER
T
H
L
1
PH_
THL1_2
T
H
L
1
(T
W
1
)
PH_TW
1
Flamm
e
W
ä
rm
e
-
a
n
fo
rd
e
ru
n
g
PH_
TSA1_2
P
H
_
STANDBY
P
H
_
THL2
P
H
_
THL2
P
H
_
THL2
PH_
THL2
PH_
THL2
Z
Z
Logisch Ein
Logisch Au
s
Bei Ab
weichu
ng
Ü
berga
ng in H
eimlau
f
Abwei
chung f
ü
hrt
zur St
ö
rstellu
ng
Bei Abw
eichun
g
Ü
bergan
g
in die a
ngegeb
ene
oder fo
lgende
Phase
Ansteu
erung
Erlaub
ter Bere
ich
Verb
otener
Bereic
h
-> He
imlauf
Verb
otener
Bereic
h
-> St
ö
rstel
lung
Ideale
s Signal
Ü
berga
ngskri
terium
Steuers
ignal
Ausl
ö
sen de
r Zwang
svorl
ü
ftung
Repeti
tion para
metrie
rbar
anschl
iessend
St
ö
rstellun
g
Z
7494f01D/1000
NoG_
Null
BV
Z
ü
ndung
LP (4)
N
o
G
_
M
a
x
N
_
V
L
N
_
T
L
N
_
V
o
r
N
_
Z
L
-N_TL_D
elta
-N_ZL_D
elta
+N_ZL_
Delta
-N_Vor_
Delta
+N_VL_D
elta
abh
ä
ngig
vo
n
Par
ame
trie
run
g
abh
ä
ngig
vo
n
Par
ame
trie
run
g
abh
ä
ngig
vo
n
Par
ame
trie
run
g
abh
ä
ngig
vo
n
Par
ame
trie
run
g
abh
ä
ngig
vo
n
Par
ame
trie
run
g
abh
ä
ngig
vo
n
Par
ame
trie
run
g
LP (3)
LP (2)
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
P
H
_
THL2
Fig. 6 BMU control centre program sequence (Type LMU64.002/A100)
(Continued on next page)
B
M
U
c
o
n
tr
o
l
ce
n
tr
e
(T
y
p
e
L
M
U
6
4
.0
0
2
/A
1
0
0
)
H
M
I
d
is
p
la
y
:
H
o
m
e
m
o
d
e
S
ta
n
d
b
y
Ope
ration
H
ea
t
re
q
u
ir
em
en
t
F
la
m
e
Ig
n
it
io
n
P
h
ase
Depending on
p
ar
am
et
er
s
et
ti
n
g
s
Depending on
pa
ramet
er
setting
s
Depending on
pa
ramet
er
sett
ing
s
D
ep
en
d
in
g
o
n
p
ar
ame
ter
setti
ng
s
Depending on
p
ar
ame
ter
se
tti
ng
s
Depending on
p
ar
ame
ter
set
tin
g
s
P
H
_
F
A
U
L
T
L
o
g
ic
O
n
L
o
g
ic
O
ff
D
ev
ia
ti
on
le
ad
s
to
f
au
lt
p
os
it
io
n
In
th
e
ev
en
t o
f
a
de
vi
at
io
n,
tr
an
si
ti
on
to
s
pe
ci
fi
ed
or
s
ub
se
qu
en
t p
ha
se
C
on
tr
ol
P
er
m
is
si
bl
e
ra
ng
e
Im
pe
rm
is
si
bl
e
ra
ng
e
->
H
om
e
m
od
e
Im
pe
rm
is
si
bl
e
ra
ng
e
->
F
au
lt
p
os
it
io
n
C
on
tr
ol
s
ig
na
l
Id
ea
l s
ig
na
l
T
ra
ns
it
io
n
cr
it
er
io
n
P
os
it
iv
e
pr
e-
pu
rg
in
g
tr
ig
ge
re
d
R
ep
et
it
io
n
pa
ra
m
et
iz
ab
le
f
ol
lo
w
ed
b
y
fa
ul
t
po
si
ti
on
In
t
h
e
ev
en
t
o
f
d
ev
ia
ti
o
n
,
tr
an
si
ti
o
n
t
o
H
o
m
e
m
o
d
e
Summary of Contents for EC Plus 120
Page 51: ...51 ...