Purpose
Κ
To set scanner sleep on or off when using “INPUT_S” command.
Syntax
Κ
INPUT_S_SLEEP(N%)
Example
Κ
R%=INPUT_S("",S1$) ‘Scanner to sleep
…
Description
Κ
N%
is an integer variable. After using “INPUT_S” command, the
“INPUT_S_SLEEP” command can set scanner to sleep or not.
If use this command and set “1”, when leaving “INPUT_S”
command, scanner will go to sleep.
N%
Meaning
0
Not sleep(scanner go to suspend)
1
To sleep
Purpose
Κ
To set the display mode of the input data.
Syntax
Κ
INPUT_MODE(mode%)
Example
Κ
INPUT_MODE(2)
Description
Κ
mode%
is an integer variable, indicating the input mode.
mode%
Meaning
0
Nothing will be displayed on the LCD.
1
The input characters will be displayed on the LCD
(default).
2
“*” will be displayed instead of the input
characters. Usually it is applied for password input.
Purpose
Κ
To enable or disable the key click sound.
Syntax
Κ
KEY_CLICK(status%)
Example
Κ
KEY_CLICK(0)
status%
is an integer variable, indicating the key click status.
status%
Key click sound
0
Disable
Description
Κ
1
Enable
T P C 7 0 3 0