Positron GAM-4-CRX Quick Installation Manual Download Page 26

GAM Quick Installation Guide 

 

 

Positron Access Solutions 

26 

Document 180-0212-001 R02 

Management

 

Web GUI Interface

 

Built-in configuration utility for browser-based device configuration (HTTP/ HTTPs). 
Supports configuration, system dashboard, maintenance, and monitoring

 

Firmware Upgrade 

Web browser upgrade (HTTP/ HTTPs) and FTP 
Secure upgrade through console port  

Dual Firmware Image

 

Dual image and firmware partition provide independent primary and secondary OS files 
for backup while upgrading.  Each firmware image has its corresponding firmware 
partition

 

SNMP 

 

SNMP version1, 2c and 3 with support for traps and SNMP version 3 user-based security 
model (USM)

 

Remote Monitoring 
(RMON)

 

Embedded RMON software agent supports RMON groups 1,2,3,9 (history, statistics, 
alarms, and events) for enhanced traffic management, monitoring and analysis

 

IPv4 and IPv6 Dual 
Stack

 

Coexistence of both protocol stacks to support a seamless migration

 

Port Mirroring

 

Traffic on a port can be mirrored to another port for Legal Interception (CALEA) or 
analysis with a network analyzer or RMON probe. Up to N-

1 (N is Switch’s Ports) ports 

can be mirrored to single destination port. A single session is supported

 

Network Time Protocol  

Network Time Protocol (NTP) for clock synchronization over packet switched networks 

Other Management

 

HTTP / HTTPs; SSH; RADIUS; DHCP Client / DHCPv6 Client; SNTP; cable diagnostics; 
ping; syslog; Telnet client (SSH secure support), IPv6 Management

 

Discovery

 

Link Layer Discovery Protocol (LLDP) (IEEE 802.1ab) with LLDP-MED extensions  

Table 5: GAM Summary Features 

 

 

Summary of Contents for GAM-4-CRX

Page 1: ...G hn Access Multiplexer GAM Quick Installation Guide GAM 4 CRX GAM 4 CX...

Page 2: ...a Published By Positron Access Solutions 5101 Buchan Street Suite 220 Montreal Quebec Canada H4P 2R9 Telephone US and Canada 1 888 577 5254 International 1 514 345 2220 Product names other than Positr...

Page 3: ...ts 8 1 2 5 GAM LED Indicators 9 1 2 6 GAM Reset Button 11 Chapter 2 12 Step by Step Installation 12 2 1 Step by Step Installation Procedure 13 Chapter 3 19 WEB Management 19 3 1 Introduction 20 3 2 Sy...

Page 4: ...THE GAM CIRCUITRY 8 FIGURE 5 GAM SERIAL MANAGEMENT PORT PINOUT 9 FIGURE 6 GAM GLOBAL STATUS LEDS 9 FIGURE 7 G HN PORTS LEDS 10 FIGURE 8 SFP LED 10 FIGURE 9 GAM RESET RST BUTTON 11 FIGURE 10 GAM LOGIN...

Page 5: ...GAM Quick Installation Guide Positron Access Solutions 5 Document 180 0212 001 R02 Chapter 1 ______________________________________ About the GAM...

Page 6: ...f DSL related technologies With G hn Operators deliver advanced services such as Gigabit High Speed Residential Internet and 4K IPTV without the high capital and operational expenses associated with a...

Page 7: ...GAM SFP Connectors The GAM has one 1 SFP ports that support any MSA compliant SFP SFP modules Fiber 1G 10G and Copper RJ 45 100M 1G Important note When connecting the SFP port to a Passive Optical Ne...

Page 8: ...ement ports located near the top right corner of the enclosure Figure 4 Local Management Ports are at the top right corner of the GAM circuitry The CRAFT port is a standard serial V 24 115200 8 N 1 po...

Page 9: ...M uses three 3 LED indicators inserted in the cover of the IP67 enclosure to provide information about its global status and operating mode Figure 6 GAM global status LEDs LED Condition Function RPF O...

Page 10: ...of the Reverse Power Feed source from a G1001 CR device at the customer end LED Condition Function G hn ports Off Blinking On Disabled or Link Down Bad or low speed G hn link Link is Up G hn port pow...

Page 11: ...is Up Link Activity Table 3 SFP LED indicator 1 2 6 GAM Reset Button Press the RST button to reset the GAM When depressed for two 2 to ten 10 seconds it will perform a cold reboot of the GAM When depr...

Page 12: ...GAM Quick Installation Guide Positron Access Solutions 12 Document 180 0212 001 R02 Chapter 2 ______________________________________ Step by Step Installation...

Page 13: ...ecting the AC DC Power supply included as part of your GAM 4 CX You should skip this step if you are using a Reverse Power Fed GAM 4 CRX unless you plan to temporarily power the GAM for a temporary 12...

Page 14: ...iver Step 3 insert the male power connector into the female receptacle You can now connect the other end of the 12Vdc 4A adapter to the local 110 220VAC power source The next step is the insertion of...

Page 15: ...ugh length to reach the SFP cage while routing the fiber cable above the 2 x RJ 45 ports at the top right of the GAM enclosure Step 6 insert the fiber connectors into the SFP SFP module Note while an...

Page 16: ...16 Document 180 0212 001 R02 You are now ready to install the ground wire into the ground lug at the bottom right edge of the GAM enclosure Step 8 insert the 6 AWG ground wire into the ground lug Ste...

Page 17: ...left top left bottom right You can now connect the coaxial cable s to the F type COAX connectors of the unit Step 11 remove the protective cap on the F type connector s where you will attach a coaxial...

Page 18: ...1 R02 Step 13 the top and bottom brackets are identical Using the Phillips screws supplied with the unit to fasten the bracket on the back side of the enclosure Step 14 Once both brackets are attached...

Page 19: ...GAM Quick Installation Guide Positron Access Solutions 19 Document 180 0212 001 R02 Chapter 3 ______________________________________ WEB Management...

Page 20: ...1 Logging into the WEB GUI The default configuration values of the GAM devices are IP Address 192 168 10 1 Subnet Mask 255 255 255 0 Username admin Password Table 4 GAM default credentials Enter the s...

Page 21: ...inistration Interface pre installed by Positron with one from your preferred Certificate Authority Note Secure HTTP is disabled by default HTTPS can be enabled via menu Configuration Security Switch H...

Page 22: ...GAM Quick Installation Guide Positron Access Solutions 22 Document 180 0212 001 R02 Chapter 4 ______________________________________ Technical Specifications...

Page 23: ...tification IEC 62368 1 Electromagnetic Compatibility EN 55032 FCC Part 15 Class A Other mark CE Operating Temperature 40 C to 65 C Storage Temperature 40 C to 70 C Operating Humidity Up to 95 relative...

Page 24: ...P or G hn ports VLAN Supports up to 4K VLANs simultaneously out of 4096 VLAN IDs Port based VLAN IEEE 802 1Q tag based VLAN IEEE 802 1ad Q in Q double tag VLAN MAC based VLAN Management VLAN Private V...

Page 25: ...s code point DSCP IP precedence TCP UDP source and destination ports 802 1p priority Ethernet type Internet Control Message Protocol ICMP packets IGMP packets TCP flag Quality of Service Hardware Prio...

Page 26: ...MON Embedded RMON software agent supports RMON groups 1 2 3 9 history statistics alarms and events for enhanced traffic management monitoring and analysis IPv4 and IPv6 Dual Stack Coexistence of both...

Page 27: ...GAM Quick Installation Guide Positron Access Solutions 27 Document 180 0212 001 R02 Chapter 4 ______________________________________ Safety and Warnings...

Page 28: ...Only qualified personnel should service this system All wiring external to the product should follow the local wiring codes Use of this product in a manner other than defined in this installation gui...

Page 29: ...iring Connection to these ports should be for temporary use during installation or maintenance THIS PRODUCT IS SUITABLE FOR MOUNTING ABOVE GROUND OR UNDER GROUND AT A MAXIMUM DEPTH OF 3 FEET THE UNIT...

Page 30: ...GAM Quick Installation Guide Positron Access Solutions 30 Document 180 0212 001 R02 Chapter 5 ______________________________________ Warranty and Customer Service...

Page 31: ...y information can be found in your Positron Access customer web portal http www positronaccess com Portal php Positron Access Solutions Sales Pricing Availability and Technical Support US and Canada 1...

Reviews: