BRX Power Injector Installation Guide
9
180-0192-001-R01
3
Quick Installation: Step-by-step Instructions
This section provides a detailed procedure to connect the power source to the BRX Power Injector.
You will also find a procedure to connect POTS pairs directly to the BRX Power Injector in the
absence of a nearby cross-connect. Finally, you will find a procedure to connect the BRX Power pairs
to the cable binder(s) connecting to the POTS port of the nearby DSLAM.
3.1 Connecting the Power Source
The BRX Power Injector offers a choice of three (3) power source:
Power Source
BRX Power Injector Ordering Codes
Local -48Vdc
BRX-PWR-8
: 8-pair BRX Power Injector with local -48Vdc input
BRX-PWR-16
: 16-pair BRX Power Injector with local -48Vdc input
BRX-PWR-24
: 24-pair BRX Power Injector with local -48Vdc input
Local 110-220Vac
BRX-PWR-8-AC
: 8-pair BRX Power Injector with local 110-220Vac input
BRX-PWR-16-AC
: 16-pair BRX Power Injector with local 110-220Vac input
BRX-PWR-24-AC
: 24-pair BRX Power Injector with local 110-220Vac input
Express Pairs
(RFT-V ±190V)
BRX-PWR-8-A:
8-pair BRX Power Injector with ALPHA Express Power input
BRX-PWR-16-A:
16-pair BRX Power Injector with ALPHA Express Power input
BRX-PWR-24-A:
24-pair BRX Power Injector with ALPHA Express Power input
BRX-PWR-8-G:
8-pair BRX Power Injector with GE Express Power input
BRX-PWR-16-G:
16-pair BRX Power Injector with GE Express Power input
BRX-PWR-24-G:
24-pair BRX Power Injector with GE Express Power input
N/A
BRX-PWR-M:
8-pair BRX Power Module to increase the pair capacity to a
maximum of 24 pairs (3 x BRX-XLR-M)
Table 1: BRX Power Injector Powering Options and Ordering Codes