Manual Kit Control Box with GUI
Page 19
Version: 2020-09-10
MANUAL
KIT CONTROL BOX WITH GUI
Figure 21: Continuous Position Reading
For the default settings with a Single Turn resolution of 17 Bit Singelturn and 16 Bit Multiturn these values
are calculated as shown in the following example:
Multiturn value = 4 decimal, equal to
4 ∙ 2
17
=
524288 in digits
Singleturn value = 0.5 decimal, equal to
0.5 ∙ 2
17
− 1 = 65535
in digits
Singleturn value in degree =
Singleturnvalue (digits)
2
17
−1
∙ 360°
=
180°
The gauge will also show the Single turn value in degree format.
To stop the continuous
reading you can press the “Stop” Button or close the window with
“Close”
button.
2.11 Update Firmware
To upgrade the firmware, you can use the “Update Firmware” function.
This option is only supported after
2.0.0 release of the Kit Control Box Software.