background image

TOUCH PANEL POS SYSTEM

Rev. : Original

TP-6000 SERIES

USER’S MANUAL

Summary of Contents for TP-6000 SERIES

Page 1: ...TOUCH PANEL POS SYSTEM Rev Original TP 6000 SERIES USER S MANUAL ...

Page 2: ...EX integrated point of sale terminal product family The TP6000 is a compact point of sale system that gives the most user friendly human interface by providing touch panel input and combines the performance and affordability of personal computers with the elegance and reliability of business machine The TP6000 also provides the built in networking capability for easy communication among multiple t...

Page 3: ... 2 1 MAIN UNIT PADDLE ASSEMBLY 2 1 OPTIONAL DEVICES 2 2 PARTS IDENTIFICATION 3 1 FRONT VIEW 3 1 SIDE VIEWS 3 2 Right Side View 3 2 Left Side View 3 2 REAR VIEW 3 3 REAR VIEW OF MAIN UNIT 3 3 ADJUSTABLE PADDLE ASSEMBLY 3 4 BOTTOM OF PADDLE ASSEMBLY 3 4 CONNECTORS 3 4 INSTALLATION GUIDES 4 1 SEPARATING MAIN UNIT 4 1 PREPARING PADDLE ASSEMBLY 4 2 INSTALLING UPS BATTERY 4 3 ROUTING THE CABLES 4 3 ...

Page 4: ...ICATION ENVIRONMENT 5 1 Ventilation 5 1 Operating Environment 5 1 Power Supply 5 1 I O Ports Utilization 5 1 External Monitor 5 2 Serial Port COM1 5 2 Serial Port COM2 5 2 POWER ON OFF 5 3 LED Indicator 5 3 Hardware Switch 5 4 Software Support 5 4 Preset Power On Control 5 4 MAGNETIC STRIPE READER 5 5 CASH DRAWER S 5 5 DISPLAY RESOLUTION 5 6 TOUCH PANEL 5 6 TOUCH TERMINAL MANAGER 5 6 RS232 TOUCH M...

Page 5: ...formation The user is encouraged to visit our web site http www posiflex com tw over the internet for further information of our products THE PRODUCT Overview The TP6000 series is one of the most compact yet fully integrated touch terminal systems This series provides on top of its excellent functionality two appearance choices for colors of the enclosure charcoal and beige Configuration AVAILABLE...

Page 6: ...hat endures 10 million up to 35 million touches at same spot i Spill proof water resistant structure allowing easy cleaning j Easy maintenance construction k Various I O ports supported including 1 one PS 2 KB port 2 one PS 2 mouse port 3 1 for TP6012R TP6015R or 2 for TP6012P TP6015P serial ports with capability for 5V DC support 4 one parallel port 5 5 USB ports 6 one LAN port 10 100 base T Ethe...

Page 7: ... touch sensor 1024 x 1024 u DRAM memory can extend to 1GB v Dual display support under OS utilizing multiple display w VGA memory size programmable by software up to 64 MB x Integrated structure for optional MSR y Software programmable MSR parameters z 2 color choices beige or charcoal OPTIONAL ITEMS Note The underlined items in the following list means that option must be set prior to shipment fr...

Page 8: ...TP6000 USER S MANUAL 1 4 ...

Page 9: ...and unfold the packaging materials carefully to unload the upsidedown loaded TP6000 series touch terminal Put this main unit paddle assembly aside for the whole Touch POS system installation Collect if exist other options from the hidden compartments in the packaging materials like external FDD Power Supply Unit Bottom of TP6000 System Carton Packaging materials Documents for Preloaded OS Power Co...

Page 10: ...cks 1 2 or tracks 2 3 and three tracks tracks 1 2 3 UPS battery COM1 terminator External Floppy disk drive There are also some options available to the TP6000 series and they may be delivered in separate packing if ordered These optional devices include External customer display Choice between PD2200 series and PD7000 series or any other Posiflex stand alone customer display POS printer Choice amo...

Page 11: ... LED in the logo area serves for multiple purposes through giving different indication of steady flashing green orange light Please refer to the paragraph discussing the LED indication in the chapter of USING THE TOUCH POS of this manual Display Screen Touch Panel Main Unit Adjustable Paddle Assembly MSR Unit ...

Page 12: ... Side View Left Side View Lock Release Lever Push In This Direction To Adjust The Tilt Angle Of The Display Panel Slide Switch For Power On Off Control Push Down To Switch The Power ON OFF Latch Hole For Cable Cover Latch Hole For Cable Cover ...

Page 13: ...ANUAL 3 3 REAR VIEW REAR VIEW OF MAIN UNIT Lock Release Button To Detach The Main Unit Optional MSR Unit Lock Release Lever Cable Exit Service Window Removal Hollow Of Cable Cover Matching Pegs Cable Exit Cable Cover ...

Page 14: ...F PADDLE ASSEMBLY CONNECTORS Pull The Cable Cover Out In This Direction Base Matching Holes Paddle Lock Release Lever Lock Release Button For Main Unit Cable Exit Cable Passage Cover UPS Battery Cover Paddle Base Turn Counterclockwise Then Take Out The Latch Key ...

Page 15: ...onnector UPS Battery Connector Cash Drawer Controller Power Input Jack COM1 Port COM2 Port External VGA Port LPT1 Printer Port PS 2 Mouse PS 2 KB External FDD Port USB2 Port USB1 Port MSR Port LAN Port USB3 Port USB4 Port USB5 Port ...

Page 16: ...TP6000 USER S MANUAL 3 6 ...

Page 17: ...r circuits to avoid high voltage hazard or electrostatic discharge damage unless the operator is well grounded SEPARATING MAIN UNIT In order to settle the touch terminal properly in a point of sale system all the cable connections have to be routed through its base the paddle assembly Therefore please press the lock release button at the rear side to separate the main unit from the paddle assembly...

Page 18: ...cable passage cover and take the cable passage cover away to show the cable passage If there is no need to install the optional UPS battery here either not to be installed or already installed please skip the next paragraph and directly start routing cables through the cable passage Otherwise please remove the four screws holding battery cover to install the battery Cable Passage Cover Screws Adju...

Page 19: ...Place all the cables required for connections to the TP6000 series except those for special application purposes into the cable passage Inset one end of the cable passage cover under the battery cover and screw on the two screws Be sure not to damage any of the cables during this operation Now turn the adjustable paddle assembly back to normal orientation and arrange all cables to come out of the ...

Page 20: ...PS battery detect function Please consult your dealer for technical support on setup of these jumpers A new Lithium battery can support the system RTC for about 3 years After the battery is nearly exhausted the user must change a new battery otherwise the system RTC and system configuration setup will be lost JOINING MAIN UNIT AND PADDLE Match the matching pegs on the back of the main unit against...

Page 21: ... down the lock release button on back of the paddle at the time lifting the main unit OPENING CABLE COVER Insert the tip of the latchkey into a latch hole on one side near bottom of the main unit Turn this key counterclockwise to the end Do the same on the opposite side Be sure to take the key out of the hole Then push the lock release lever on the base backward to adjust the paddle to the most ho...

Page 22: ...over on the main unit Adjust the tilt angle of the main unit for best viewing effect in the application CAUTION Before doing any insertion or extraction of the power plug be sure to pull always the outer sleeve of the plug backward to release the internal latch Failure to do this could damage the power plug Such damage is considered as an artificial destruction and is not covered by the warranty I...

Page 23: ... the main unit with the four matching holes in the bracket to hold the main unit in the similar manner as installing the main unit onto the paddle assembly The paddle assembly is not engaged in wall mount operation LOCATION FOR INSTALLATION As the paddle assembly is not involved in wall mount installation the space required for wall mount application will take only the main unit into consideration...

Page 24: ...TP6000 USER S MANUAL 4 8 either 360 mm or 380 mm depending on the position adjusted When the main unit is tilted to near horizontal position the total height required is 275 mm ...

Page 25: ...o 35 C and up to 80 humidity non condensing Power Supply The operating voltage range of the power adaptor should cover the local power supply for proper operation The power cable the power outlet and any power fusing arrangements must conform to local safety regulations I O Ports Utilization The TP6000 series designed to accommodate today s and tomorrow s technology has an adequate yet not vast nu...

Page 26: ...rnal VGA port in the TP6000 series supports any regular VGA monitor using separate AC power up to resolution 1024 x 768 with true color Unlike other Posiflex POS terminals the DC powered 9 VGA mono monitor is not supported by this series Serial Port COM1 CAUTION COM1 serial port must always be occupied by either a suitable serial device or COM1 terminator as supplied Without this provision the cas...

Page 27: ...xternal power extinguishes and the TP6000 is working on the optional UPS battery power the green LED flashes When the optional UPS battery is going to exhaust by supporting the TP6000 in the absence of the external power the orange LED flashes rapidly When the TP6000 is turned off and the external power disappears the LED is off This system will not allow powering the system up in the absence of a...

Page 28: ...ature does not apply in this mode Of course the application program shall take care of the means for turning the system off Software Support The TP6000 series provides a software power off command for the application program maneuvers The TP6000 also provides a specific means for the software to detect if the system is working on external or UPS battery power So the application program can operate...

Page 29: ...a complete boot up procedure the above preset power on control functions will be disabled until next turning off after a complete boot up MAGNETIC STRIPE READER The magnetic stripe reader if installed will be mounted on the right edge of the TP6000 series When reading an ISO standard magnetic card please face the magnetic stripe to the center of TP6000 series and slide the card downward through th...

Page 30: ...uched is dragged across the screen surface it can respond as if the mouse is dragged across with left key pressed If the point is touched released and touched within a short time interval it can work just like double clicking the mouse For the standard PS2 interfaced touch panel controller touching the screen for a while followed by a slight move of the touch without leaving the screen surface can...

Page 31: ...software power off and whether an UPS battery is engaged in the power control system RS232 TOUCH MONITOR MOUSE If the product model purchased is TP6012R or TP6015R the touch panel controller used is the RS232 interfaced controller The Touch Panel Manager of the above Posiflex Touch Terminal Manager should be discarded and a separate software Monitor Mouse should be used In these models the connect...

Page 32: ...TP6000 USER S MANUAL 5 8 If for any reason the user wants to remove the driver for the RS232 touch controller please select Monitor Mouse for Windows 95 in the program list for removal ...

Reviews: