Start-up
Before starting to operate the machine, please check that the protective and safety systems
are working and also the hydraulic hoses and oil level.
Driven by electric motor (type E)
Machines with 230 V motor
The machine must only be operated on electric circuits equipped with 30 mA FI fault current
protection or a Portable Residual Current Device (PRCD).
Work on electrical equipment must only be carried out by qualified electricians.
▪ Connect the machine to the mains:
– mains voltage 230 V (50 Hz)
– fuse 16 A
– Use a power supply cable with a cross-section of at least 2.5 mm².
▪ Press the green ON button.
Machines with 400 V motor
The machine must only be operated on electric circuits equipped with 30 mA FI fault current
protection or a Portable Residual Current Device (PRCD).
Work on electrical equipment must only be carried out by qualified electricians.
Type E3
Connect the machine to the mains:
▪ Mains voltage 400 V / 50 Hz
▪ Circuit-breaker 16 A (tripping characteristic C)
▪ For the feed, a cable cross-section of at least 2.5 mm² must be used.
This cable cross-section is only a minimum specification. In the event of a lengthy
supply cable, its size must be determined by an electrician.
▪ Press the green ON button.
Note the rotation direction of the electric motor (see arrow on motor).
If the motor is rotating in the wrong direction:
A phase inverter in the plug controls the direction of rotation of the motor (press in the disc
in the plug with a screwdriver and turn 180˚).