Start-up
Before starting to operate the machine, please check that the protective and safety systems
are working and also the hydraulic hoses and oil level.
Before each start-up, the condition of the electrical cables must be checked.
Please check the operation of the wood grip in particular!
If a fault occurs during operation, the machine must be shut down immediately.
Driven by electric motor (type E)
Machines with 400 V motor
The machine must only be operated on electric circuits equipped with 30 mA FI fault current
protection or a Portable Residual Current Device (PRCD).
Work on electrical equipment must only be carried out by qualified electricians.
Type E5.5
Connect the machine to the mains:
▪ Mains voltage 400 V (50 Hz)
▪ Circuit-breaker 16 A (tripping characteristic C)
▪ For the feed, a cable cross-section of at least 2.5 mm² must be used.
This cable cross-section is only a minimum specification. In the event of a lengthy
supply cable, its size must be determined by an electrician.
▪ Turn the switch to the ON position.
1
2
1
Neutral position
2
On position
If the electric motor will not start (red light for rotational direction detection is on):
A phase inverter in the plug controls the direction of rotation of the motor (press in the disc
in the plug with a screwdriver and turn 180˚).
4
4.1
4.1.1
Start-up
15