background image

- 22 - 

                                   

 

    Start configuration                                            End configuration 

 

ITEM 

OPTION 

 

*Disable 

Bar Code ID 

 

Enable 

 

* Read 1 Time 

Accuracy 

 

Read 2 Times 

 

Bar equals high

 

 

 

Reading

 

 

Bar equals low

 

 

 

 

 

 
 

Code Type   

ID 

Code Type 

ID 

UPC-A 

Interleaved 25 

UPC-E 

Industrial 25 

EAN-13 

Matrix 25 

EAN-8 

China Postal Code 

Code 39 

MSI/Plessey 

Codabar 

Code 32 

  Code 93 

  Code 11 

  T 

Code 128 

  Telepen   

  V     

Summary of Contents for ION Short Range

Page 1: ...Barcode Scanner User s Guide ION Short Range POINT OF SALE SIMPLIFIED...

Page 2: ...ning mode selection 16 2 3 Beeper tone selection 17 2 4 String Options Prefix Suffix 18 2 5 Setup Insertion 19 Chapter 3 BarCode parameters setting 3 1 UPC A 23 3 2 UPC E 26 3 3 EAN 13 29 3 4 EAN 8 31...

Page 3: ...on se ngs If you need to change these se ngs programming is accomplished by scanning the barcodes in this guide 1 2 How to set up the parameter I 1 Scan Start Con gura on 2 3 Scan End Con gura on to e...

Page 4: ...des such as pre x or su x Numeric barcode such as inter character delay or min max length Generally you will only need to scan one barcode for most parameters You will hear two beeps when you successf...

Page 5: ...The scanner is designed to switch easily from interfaces Start con gura on End con gura on ITEM OPTION KEYBOARD RS 232 USB Interface Selec on USB COM No con guration is required for USB interface Simp...

Page 6: ...Keyboard emulation parameters setting Start configuration End configuration ITEM OPTION IBM AT IBM XT IBM PS 2 30 80 IBM 5550 PS 2 25 30 NEC 9801 Reserved 1 Device Selection for keyboard Interface Re...

Page 7: ...7 Start configuration End configuration ITEM OPTION USA ITALIAN SPANISH FRENCH GERMAN JAPANESE Multi Language Support Language for Keyboard Interface Reserved 1...

Page 8: ...le Func on Key Enable Disable Emulate External Keyboard Enable Disable ALT Mode Enable NOTE Emulate External Keyboard Scan the Enable barcode if you do not have an external keyboard After scanning the...

Page 9: ...9 Start configuration End configuration ITEM OPTION Disable Caps Lock Enable Disable Num Lock Enable Inter Character Delay Default 00 Ref Appendix 00 64H...

Page 10: ...0 Start configuration End configuration ITEM OPTION None CR Tab ESC Terminator CR LF Block transmission delay Default 00 Ref Appendix 00 0AH Keyboard Speed Default 00 high clock rate Ref Appendix 00 0...

Page 11: ...11 2 1 2 RS 232 communication setting Start configuration End configuration ITEM OPTION 1200bps 2400bps 4800bps 9600bps 19200bps Baud Rate 38400bps 7 Bits Data Bits 8 Bits...

Page 12: ...12 Start configuration End configuration ITEM OPTION 1 Stop Bits Stop Bits 2 Stop Bits NONE ODD EVEN Mark Parity Space...

Page 13: ...End con gura on ITEM OPTION Inter character delay Default 00 Ref Appendix 00 64H Block transmission delay Default 00 Ref Appendix 00 0AH Response delay Default 00 Ref Appendix 00 0AH None RTS CTS ACK...

Page 14: ...14 Start configuration End configuration ITEM OPTION None CR LF CR LF Tab STX ETX Terminator For RS 232 EOT...

Page 15: ...15 Start configuration End configuration ITEM OPTION None RTS CTS ACK NAK Handshaking Xon Xoff...

Page 16: ...ection Start configuration End configuration ITEM OPTION Trigger On Good Read Off Trigger On Off Continuous Trigger Off Continuous Testing Continuous Trigger on Continuous Auto power on Flash Reading...

Page 17: ...eeper tone selection Start configuration End configuration ITEM OPTION Beep Tone Default 09H Ref Appendix 00 10H Beep Sound Duration Default 05H Ref Appendix 00 10H Enable Power On Beeper Disable ON B...

Page 18: ...on barcode 2 Scan Preamble barcode 3 Scan twice from FULL ASCII table 4 Scan Con rm con gura on barcode 5 Scan End Con gura on barcode How to set up a su x To con gure as su x 1 Start con gura on bar...

Page 19: ...the same time G1 Insertion Character G2 Insertion Character G2 Character Position Insertion Group Selection 02 Insertion Group Selection 02 G1Character Position Insertion Group Selection 01 Insertion...

Page 20: ...e character 6 Scan Start Con gura on barcode 7 Scan G1 Character Posi on 8 Scan 0 and 3 from FULL ASCII Table which p r e e sents the posi on 9 Scan Con rm con gura on barcode 10 Scan End con gura on...

Page 21: ...amble Default 00 Ref Appendix Postamble Default 00 Ref Appendix G1 Insertion character Default 00 Ref Appendix G2 Insertion character Default 00 Ref Appendix G1 Character Position to be inserted Defau...

Page 22: ...Read 1 Time Accuracy Read 2 Times Bar equals high Reading Bar equals low Code Type ID Code Type ID UPC A F Interleaved 25 N UPC E G Industrial 25 O EAN 13 H Matrix 25 P EAN 8 I China Postal Code Q Cod...

Page 23: ...hapter 3 Barcode parameters se ng How to set up a Code ID 1 Scan Start con gura on barcode 2 3 Scan Con rm con gura on barcode 4 Scan End con gura on barcode Start con gura on End con gura on Con rm c...

Page 24: ...TION Disable UPC A Expand to EAN 13 Enable Disable Check Digit Send Enable Disable Truncate Leading Zero Enable Truncate Leading Default 00 Ref Appendix 00 0DH Truncate Ending Default 00 Ref Appendix...

Page 25: ...25 Start configuration End configuration ITEM OPTION NONE 2 digits 5 digits 2 or 5digits Supplement digits Auto discriminate Supplement...

Page 26: ...26 3 2 UPC E Start configuration End configuration ITEM OPTION Disable Read Enable Code ID setting Default G Ref Appendix 20 7EH...

Page 27: ...ation ITEM OPTION Disable UPC E Expand to UPC A Enable Disable Check Digit Send Enable Truncate Leading Default 00 Ref Appendix 00 08H Truncate Ending Default 00 Ref Appendix 00 08H Insert group selec...

Page 28: ...28 Start configuration End configuration ITEM OPTION Disable Truncate Leading Zero Enable None 2 digits 5 digits 2 or 5 digits Supplement digits Auto discriminate Supplement...

Page 29: ...ation End configuration ITEM OPTION Disable Read Enable Code ID setting Default H Ref Appendix 20 7EH Disable Check Digit Send Enable Truncate Leading Default 00 Ref Appendix 00 0DH Truncate Ending De...

Page 30: ...iguration End configuration ITEM OPTION None 2 digits 5 digits 2 or 5 digits Supplement digits Auto discriminate Supplement Disable ISBN ISSN Conversion Enable Insert group selection Default 00 Ref Ap...

Page 31: ...4 EAN 8 Start configuration End configuration ITEM OPTION Disable Read Enable Code ID setting Default I Ref Appendix 20 7EH Disable Check Digit Send Enable Truncate Leading Default 00 Ref Appendix 00...

Page 32: ...tion End configuration ITEM OPTION Truncate Ending Default 00 Ref Appendix 00 08H None 2 digits 5 digits 2 or 5 digits Supplement digits Auto discriminate Supplement Insert group selection Default 00...

Page 33: ...3 5 Code39 Start configuration End configuration ITEM OPTION Disable Read Enable Code ID setting Default J Ref Appendix 20 7EH Disable Check sum verification Enable Disable Check sum transmission Ena...

Page 34: ...art configuration End configuration ITEM OPTION Disable Append Enable Min code length Default 00 Ref Appendix 00 32H Max code length Default 32H Ref Appendix 00 32H Standard Code39 Format Code 39 Full...

Page 35: ...End configuration ITEM OPTION Disable Transmit Start End Character Enable Truncate Leading Default 00 Ref Appendix 00 32H Truncate Ending Default 00 Ref Appendix 00 32H Insert group selection Default...

Page 36: ...36 3 6 Codabar Start configuration End configuration ITEM OPTION Disable Read Enable Code ID setting Default K Ref Appendix 20 7EH...

Page 37: ...37 Start configuration End configuration ITEM OPTION Disable Check sum verification Enable Disable Check sum transmission Enable Disable Append Enable Truncate Leading Default 00 Ref Appendix 00 7EH...

Page 38: ...guration End configuration ITEM OPTION Truncate Ending Default 00 Ref Appendix 00 7EH ABCD ABCD abcd abcd Start End type abcd tn e Disable Start End transmission Enable Min code length Default 05 Ref...

Page 39: ...39 Start configuration End configuration ITEM OPTION Max code length Default 3CH Ref Appendix 00 3CH Insert group selection Default 00 Ref Appendix 00 02H...

Page 40: ...40 3 7 Code93 Start configuration End configuration ITEM OPTION Disable Read Enable Code ID setting Default L Ref Appendix 20 7EH Disable Check sum verification Enable...

Page 41: ...Check sum transmission Enable Min code length Default 00 Ref Appendix 0 50H Max code length Default 50H Ref Appendix 0 50H Truncate Leading Default 00 Ref Appendix 00 7EH Truncate Ending Default 00 R...

Page 42: ...42 3 8 Code 128 Start configuration End configuration ITEM OPTION Disable Read Enable Code ID setting Default M Ref Appendix 20 7EH Disable Check sum verification Enable...

Page 43: ...43 Start configuration End configuration ITEM OPTION Disable Check sum transmission Enable Disable FNC2 Append Enable Disable UCC EAN128 Enable Disable FNC1 transmission Enable...

Page 44: ...TION Truncate Leading Default 00 Ref Appendix 00 7FH Truncate Ending Default 00 Ref Appendix 00 7FH Min code length Default 00 Ref Appendix 00 7FH Max code length Default 7FH Ref Appendix 00 7FH Inser...

Page 45: ...nterleaved 2 of 5 Start configuration End configuration ITEM OPTION Disable Read Enable Code ID setting Default N Ref Appendix 20 7EH Disable Check sum verification Enable Disable Check sum transmissi...

Page 46: ...TION Truncate Leading Default 00 Ref Appendix 00 7EH Truncate Ending Default 00 Ref Appendix 00 7EH Min code length Default 00 Ref Appendix 00 7FH Max code length Default 7FH Ref Appendix 00 7FH Inser...

Page 47: ...2 of 5 Start configuration End configuration ITEM OPTICON Disable Read Enable Code ID setting Default O Ref Appendix 20 7EH Min code length Default 00 Ref Appendix 00 32H Max code length Default 32H...

Page 48: ...on ITEM OPTION Truncate Leading Default 00 Ref Appendix 00 32H Truncate Ending Default 00 Ref Appendix 00 32H Disable Check sum verification Enable Disable Check sum transmission Enable Insert group s...

Page 49: ...49 3 11 Matrix 2 of 5 Start configuration End configuration ITEM OPTION Disable Read Enable Code ID setting Default P Ref Appendix 20 7EH Disable Check sum verification Enable...

Page 50: ...sum transmission Enable Truncate Leading Default 00 Ref Appendix 00 50H Truncate Ending Default 00 Ref Appendix 00 50H Min code length Default 0B Ref Appendix 00 50H Max code length Default 50H Ref Ap...

Page 51: ...CHINA POSTAL CODE Start configuration End configuration ITEM OPTION Disable Read Enable Code ID setting Default Q Ref Appendix 20 7EH Disable Check sum verification Enable Disable Check sum transmissi...

Page 52: ...TION Truncate Leading Default 00 Ref Appendix 00 50H Truncate Ending Default 00 Ref Appendix 00 50H Min code length Default 00 Ref Appendix 00 50H Max code length Default 50H Ref Appendix 00 50H Inser...

Page 53: ...53 3 13 MSI Plessey Start configuration End configuration ITEM OPTION Disable Read Enable Code ID setting Default R Ref Appendix 20 7EH Disable MOD 10 MOD 10 10 Check sum verification MOD 11 10...

Page 54: ...sum transmission Enable Truncate Leading Default 00 Ref Appendix 00 3CH Truncate Ending Default 00 Ref Appendix 00 3CH Min code length Default 00 Ref Appendix 00 3CH Max code length Default 3CH Ref Ap...

Page 55: ...32 Italian Pharma Code Start configuration End configuration ITEM OPTION Disable Read Enable Code ID Setting Default S Ref Appendix 20 7EH Disable Check sum verification Enable Disable Check sum trans...

Page 56: ...56 Start configuration End configuration ITEM OPTION Truncate Leading Default 00 Ref Appendix 00 0AH Truncate Ending Default 00 Ref Appendix 00 0AH Insert group selection Default 00 Ref Appendix 00 02...

Page 57: ...57 3 15 CODE 11 Start configuration End configuration ITEM OPTION Disable Read Enable Code ID setting Default T Ref Appendix 20 7EH Disable Check sum verification Enable...

Page 58: ...sum transmission Enable Truncate Leading Default 00 Ref Appendix 00 50H Truncate Ending Default 00 Ref Appendix 00 50H Min code length Default 00 Ref Appendix 00 50H Max code length Default 50H Ref Ap...

Page 59: ...3 16 Telepen Start configuration End configuration ITEM OPTION Disable Read Enable Code ID setting Default V Ref Appendix 20 7EH Disable Check sum verification Enable Only Numnic Data Format Full ASC...

Page 60: ...sum transmission Enable Truncate Leading Default 00 Ref Appendix 00 40H Truncate Ending Default 00 Ref Appendix 00 40H Min code length Default 00 Ref Appendix 00 40H Max code length Default 40H Ref Ap...

Page 61: ...61 3 17 GS1 Data Bar RSS Start configuration End configuration ITEM OPTION Enable RSS 14 Disable Enable RSS 14 LIMITED Disable Enable RSS 14 EXPANDED Disable Enable RSS TO UPC EAN Disable...

Page 62: ...N Disable Function Key Enable Code 39 format Full ASCII Code 39 To scan a function key barcode label Full ASCII Code 39 must be enabling Please refer to Full ASCII Code 39 Table to produce the functio...

Page 63: ...63 PAGE UP E F5 U PAGE DOWN F F6 V BS H F7 W TAB I F8 X HOME K F9 Y END L F10 Z ENTER M ESC A INSERT N F11 B DELETE O F12 C...

Page 64: ...64 Appendix A...

Page 65: ...HT 41 29 10 0A LF 42 2A 11 0B VT 43 2B 12 0C FF 44 2C 13 0D CR 45 2D 14 0E SO 46 2E 15 0F SI 47 2F 16 10 DLE 48 30 0 17 11 DC1 49 31 1 18 12 DC2 50 32 2 19 13 DC3 51 33 3 20 14 DC4 52 34 4 21 15 NAK...

Page 66: ...3 49 I 105 69 i 74 4A J 106 6A j 75 4B K 107 6B k 76 4C L 108 6C l 77 4D M 109 6D m 78 4E N 110 6E n 79 4F O 111 6F o 80 50 P 112 70 P 81 51 Q 113 71 q 82 52 R 114 72 r 83 53 S 115 73 s 84 54 T 116 74...

Page 67: ...67 Table Hex HEXADCIMAL Confirm configuration End Configuration...

Page 68: ...68 Function Key Table 0 1 0 NULL 1 UP F1 2 DOWN F2 3 LEFT F3 4 RIGHT F4 5 PAGE UP F5 6 PAGE DOWN F6 7 F7 8 BS F8 9 TAB F9 A F10 B HOME ESC C END F11 D ENTER F12 E INSERT F DELETE...

Page 69: ...69 DEFAULT CHECK VERSION Version 3 1...

Reviews: