- 18 -
2.4 String Op ons (Pre
fi
x & Su
ffi
x)
This sec on describes the altera ons which can be made to the format of
the transmi ed data string.
Format
{Pre
fi
x} {Code ID} {Bar Code} {Su
ffi
x}
How to set up a pre
fi
x?
To con
fi
gure “## “as pre
fi
x
(1)
Scan Start Con
fi
gura on barcode
(2)
Scan Preamble bar code
(3)
Scan ‘#” twice from FULL ASCII table
(4)
Scan Con
fi
rm con
fi
gura on barcode
(5) Scan End Con
fi
gura on barcode.
How to set up a su
ffi
x?
To con
fi
gure “$$” as su
ffi
x
(1)
Start con
fi
gura on barcode
(2)
Scan Postamble barcode
(3)
Scan ‘$” twice from FULL ASCII table
(4)
Scan Con
fi
rm con
fi
gura on barcode
(5)
Scan End con
fi
gura on barcode.
A prefix and suffix, 10 characters maximum, may
be included in front of or at the end of a scanned barcode.