WADE-8110 User’s Manual
24 / 26
WDT Control Timer Configuration Register
Bit Description
7
WDT Time-out Value Select 1
1 : Second
0 : Minute
6
WDT Output through KRST (Pulse) Enable (WOKE)
1 : Enable
0 : Disable
5
WDT Time-out value Extra select (WTVES)
1 : 64 ms x WDT Timer-out value (default = 4s)
0 : Determined by WDT Time-out value select 1 (bit 7 of this register).
4
WDT Output through PWROK (Pulse) Enable (WOPE)
1 : Enable
0 : Disable
During LRESET#, this bit is selected by JP7 power-on strapping option
3-0
Select interrupt level
Note1
for WDT (SIL)
Note 1 :
Interrupt level mapping
Fh – Dh : not valid
Ch : IRQ12
3h : IRQ3
2h : not valid
1h : IRQ1
0h : no interrupt mapping
WDT Control Timer Time-Out Value (LSB) Register
Bit Description
7-0
WDT Time-out Value 7-0 (WTV)
Register Location:
LDN=07h Index=72h
Attribute:
Read/Write
Size:
8bit
Register Location:
LDN=07h Index=73h
Attribute:
Read/Write
Size:
8bit