Shown below is a sample of the programming steps for individual versus multiple operation of four backstops. 
 

Individual Operation (Backstops 3 thru 6 
Operate Individually) 

 

Example No. 1: 

To program 

Backstop 3

 to 

RELAY SET B

 (002) on panel 

address 

"0"

1.  Enter the relay set number:

 002

 

2.  Press the device type:

 Backstop

 

3.  Enter the device number:

 03

 

4. Press 

the 

DOWN / Off

 button. 

 

Example No. 2: 

To program 

Backstop 4

 to 

RELAY SET E

 (005) on panel 

address 

"0"

1.  Enter the relay set number:

 005

 

2.  Press the device type:

 Backstop

 

3.  Enter the device number:

 04

 

4. Press 

the 

DOWN / Off

 button. 

 

Example No. 3: 

To program 

Backstop 5

 to 

RELAY SET A

 (009) on panel 

address 

"1"

1.  Enter the relay set number:

 009

 

2.  Press the device type:

 Backstop

 

3.  Enter the device number:

 05

 

4. Press 

the 

DOWN / Off

 button. 

 

Example No. 4: 

To program 

Backstop 6

 to 

RELAY SET G

 (015) on panel 

address 

"1"

1.  Enter the relay set number:

 015

 

2.  Press the device type:

 Backstop

 

3.  Enter the device number:

 06

 

4. Press 

the 

DOWN / Off

 button. 

 

Multiple Operation (Backstops 3 thru 6 Operate 
Simultaneously) 

 

Example No. 1: 

To program 

Backstop 3

 to 

RELAY SET B

 (002) on panel 

address 

"0"

1.  Enter the relay set number:

 002

 

2.  Press the device type:

 Backstop

 

3.  Enter the device number:

 60

 

4. Press 

the 

DOWN / Off

 button. 

 

Example No. 2: 

To program 

Backstop 4

 to 

RELAY SET E

 (005) on panel 

address 

"0"

1.  Enter the relay set number:

 005

 

2.  Press the device type:

 Backstop

 

3.  Enter the device number:

 60

 

4. Press 

the 

DOWN / Off

 button. 

 

Example No. 3: 

To program 

Backstop 5

 to 

RELAY SET A

 (009) on panel 

address 

"1"

1.  Enter the relay set number:

 009

 

2.  Press the device type:

 Backstop

 

3.  Enter the device number:

 60

 

4. Press 

the 

DOWN / Off

 button. 

 

Example No. 4: 

To program 

Backstop 6

 to 

RELAY SET G

 (015) on panel 

address 

"1"

1.  Enter the relay set number:

 015

 

2.  Press the device type:

 Backstop

 

3.  Enter the device number:

 60

 

4. Press 

the 

DOWN / Off

 button. 

 

 
In the above individual and multiple programming examples, Backstops 3, 4, 5 or 6 will operate individually when the operator at the 
TouchPad enters 

Backstop 3, 4, 5 or 6

 and presses and holds either the 

UP

 or 

DOWN

 button.  These four backstops will operate 

simultaneously when the operator at the TouchPad enters 

Backstop 60

 and presses and holds either the 

UP

 or 

DOWN

 button. 

 
 
 
 

Multiple Operation

 notes: 

 

A maximum of four (4) backstops or height adjusters can be operated simultaneously (multiple operation). 

 

Each member of a multiple operation set must be powered by a separate relay bank (see pages 11, 16 and 17 of the manual). 

 

Any device number can be assigned to operate a multiple operation set, but number assignments 50 thru 99 are 
recommended. 

 

Only the 

Backstop

 and 

MISC.

 function keys can be programmed for multiple operation.  The 

Curtain

 function key 

cannot

 

be programmed for multiple operation. 

 

A Powr-Touch

®

 II system with only one relay panel can control only two devices simultaneously.  A minimum of two relay 

panels is required to control a multiple set of four devices. 

 
 
 
 
 
 
 
 

Reviews: