Porter 00700-000 Installation, Operation & Maintenance Manual Download Page 3

 

3

Detail "B"

3"

8"

16"

2'-6"

.

912"

512"

2"

2"

8"

6"

HEIGHT OF

WINCH

16"

7'-0"

MINIMUM DISTANCE

FROM BOTTOM

OF WINCH TO

FINISHED FLOOR

MINIMUM OF FOUR 

ANCHORS REQUIRED - 

SEE METHODS A, B OR C 

IN DETAIL "C"

ANCHOR WOOD PAD / WINCH TO WALL 

 

3. 

Before installing wood pad/winch assembly to 
wall, verify exact location of winch with 
owner or architect.  In determining the exact 
winch location, the following must be 
considered: 

 

The operator must have a clear view of 
the equipment he/she is operating. 

 

Anticipate path of cable between winch 
and pulley(s).  Structural members, lights, 
ducts, drain pipes, etc. are potential 
obstacles. 

 

The path of the cable cannot cause it to 
contact any part of the backstop mast 
during the folding cycles. 

 

Extensive cable travel will require 
additional idler pulleys to support the 
cable run. 

Refer to separate installation manual supplied 
with backstops, etc. for supplemental 
information on winch location, cable routing, 
etc. 

 

4. 

Anchor wood pad/winch assembly (from Step 
No. 2) to wall, using one of three suggested 
anchor detail methods shown in Detail "C".  
See Detail "B" for anchor spacing on wood 
pad.  Consult with architect or engineer to 
verify wall capacity and to select appropriate 
connections. 

 
 
 

5. 

As an alternate, the winch can be mounted to 
the face of a steel column (not shown). 

 
 

EXISTING WALL (ANCHORS)

A

DURING CONSTRUCTION

EXISTING WALL (THRU-BOLT)

B

C

Detail "C"

1/2"

GALVANIZED

MACHINE

BOLT

GALVANIZED

BUILDING

WASHER

212"

HOLD
FOR
WOOD
PAD

GALVANIZED

BUILDING

WASHER

1/2"

GALVANIZED

MACHINE

BOLT

HOLD
FOR
WOOD
PAD

212"

ANCHORS
WITH

1/2" x 4" Lg.

LAG SCREW

WOOD PAD
(BY PORTER)

RAWL
MASONRY
ANCHORS

ONLY POSSIBLE AT TIME

THAT WALL IS CONSTRUCTED

THRU-BOLTING FOR

CONCRETE OR MASONRY WALLS

INSTALL ANCHORS INTO HORIZONTAL MORTAR JOINTS 

ON SPACING AS SHOWN IN DETAIL "B".  

NEVER

 

INSTALL ANCHORS INTO OPEN CELL OF BLOCK.

NOTE - ALL HARDWARE FOR ATTACHING WOOD PAD TO WALL ARE BY OTHERS.  VERIFY MATERIAL AND THICKNESS 

OF WALL, AND USE APPROPRIATE HARDWARE / ANCHOR COMBINATION (MINIMUM 1/2" DIA. HARDWARE).