background image

Pancake 
Compressor

Instruction

manual

Part No. A07300-049-0

®

ESPAÑOL: PÁGINA 19

FRANÇAIS : PAGE 37

To learn more about Porter-Cable 

visit our website at: 

http://www.porter-cable.com

Copyright © 2004 Porter-Cable Corporation

PROFESSIONAL POWER TOOLS

MODEL 

CFFN250N

CFFN250B

CFBN125A

The Model and Serial No. plate is located on the main 
housing of the tool. Record these numbers in the 
spaces below and retain for future reference.

Model No. ______________________________________

Type ___________________________________________

Serial No.  ______________________________________

IMPORTANT

Please make certain that the person who 
is to use this equipment carefully reads 
and understands these instructions before 
starting operations.

Summary of Contents for CFBN125A

Page 1: ...250B CFBN125A The Model and Serial No plate is located on the main housing of the tool Record these numbers in the spaces below and retain for future reference Model No _______________________________...

Page 2: ...the symbols below Please read the manual and pay attention to these symbols IMPORTANT SAFETY INSTRUCTIONS Some dust created by power sanding sawing grinding drilling and other construction activities...

Page 3: ...roperty damage To reduce the risk of fire do not allow the compressor to operate unattended Always operate the compressor in a well ventilated area free of combustible materials gasoline or solvent va...

Page 4: ...ndensed water from tank causing rust and thinning of the steel tank Modifications or attempted repairs to the tank Unauthorized modifications to the unloader valve safety valve or any other components...

Page 5: ...ect voltage and adequate fuse protection Sprayed materials such as paint paint solvents paint remover insecticides weed killers may contain harmful vapors and poisons Work in an area with good cross v...

Page 6: ...thing WARNING Risk of Falling A portable compressor can fall from a table workbench or roof causing damage to the compressor and could result in serious injury or death to the operator Always operate...

Page 7: ...parts WARNING Risk of Unsafe Operation Unsafe operation of your air compressor could lead to serious injury or death to you or others HAZARD WARNING Risk of Serious Injury or Property Damage When Tran...

Page 8: ...restarts is called cut in pressure Cut Out Pressure When an air compressor is turned on and begins to run air pressure in the air tank begins to build It builds to a certain high pressure before the...

Page 9: ...grounding reduces the risk of shock by providing an escape wire for the electric current This air compressor must be properly grounded The portable air compressor is equipped with a cord having a gro...

Page 10: ...6 OR 18 AWG Voltage and Circuit Protection Refer to the specification chart for the voltage and minimum branch circuit requirements Risk of Opertion Certain air compressors can be operated on a 15 amp...

Page 11: ...controls before operating the unit On I Off O Switch Place this switch in the ON I position to provide automatic power to the pressure switch and OFF O to remove power at the end of each use Pressure...

Page 12: ...eck Valve When the air compressor is operating the check valve is open allowing compressed air to enter the air tank When the air compressor reaches cut out pressure the check valve closes allowing ai...

Page 13: ...ponsibilities Daily or after each use Before each use Check Safety Valve Drain Tank NOTE See Operation section for the location of controls Unit cycles automatically when power is on When performing m...

Page 14: ...then be removed cleaned the reinstalled To Replace or Clean Check Valve 1 Release all air pressure from air tank See To Drain Tank in the Maintenance section 2 Unplug unit 3 Remove the hose by removin...

Page 15: ...ghten with wrench 9 Reapply pipe sealant to gauges quick connect and safety valve 10 Reassemble all components in reverse order of removal Make sure to orient gauges to read correctly and use wrenches...

Page 16: ...proximately 20 psi Release safety valve ring 6 Drain water from air tank by opening drain valve on bottom of tank Risk of Bursting Water will condense in the air tank If not drained water will corrode...

Page 17: ...17 ENG A07300 NOTES...

Page 18: ...ser Air compressors with 60 and 80 gallon tanks will be inspected at the site of installation Contact the nearest Porter Cable Authorized Warranty Service Center that provides on site service calls fo...