S3500 Cell

The 

S3500

  cell  must  be  installed  horizontally  (level)  within  5  degrees,  in  the  return  to  pool  line.

 

The 

two  plumbing  inlets  must  point  down.   

S3500 Power Pack

The Power Pack must be mounted on a vertical wall or fence within 1.5 metres of the cell and at least 1 metre 
above the ground.  The Power Pack must also be in a position to allow its supply lead to be plugged into a 10 amp 
240 volt power point. 

Select a suitable place to attach the mounting bracket, at least 1 metre above the ground and clear from hazards.  
Ensure that the location selected is well ventilated (allowing plenty of airflow behind the unit) and is not in direct 
sunlight (If mounted in direct sunlight the LED indicators will be less visible).  The suitable location must not be 
attached to or on top of a source producing large amounts of heat (e.g. metal fence or shed wall).

Mount the bracket horizontally ensuring that the vent louvers above the screws are facing upwards. Carefully 
hook the Power Pack onto the mounting bracket. 

Connecting the Pool Pump

Raise the tinted Control Panel Cover on the front of the Power Pack and loosen the two retaining screws in the 
bottom right hand corner and remove the cable entry cover by pulling downwards.   Plug the pool pump into 
the pump socket on the front of the unit.  Refit the cable entry cover making sure all cables pass through the 
tunnel behind it to ensure they do not interfere with the proper closing of the Control Panel Cover.
Tighten retaining screws.

Off-Peak Installations

This unit is suitable for off-peak tariff supply (but will require installation by a suitably qualified tradesman).

Heaters and other

equipment in the return

to pool line must be

installed before the cell 

(i.e. Between the cell

and filter)

Remember:

The filter pump must be 

plugged into the Power Pack.

When secure, plug the lead 

into a suitable 240 volt power 

point, but DO NOT SWITCH THE 

UNIT ON

Connecting a pump load 

greater than 1.5kW, or the use 

of double adapters/stackable 

plugs will void the warranty.

Standard

What Salt Concentration to Use

We recommend that your S3500 salt concentration be maintained at a level of between 5000 and 7000 ppm.