Poniie PN1500 User Manual Download Page 1

 

User Manual

 

 

Model No: 

PN1500 

 

Thank you for purchasing the 

Electricity Usage Monitor

 by Poniie. Please 

read this manual carefully before using this product.   

Summary of Contents for PN1500

Page 1: ...User Manual Model No PN1500 Thank you for purchasing the Electricity Usage Monitor by Poniie Please read this manual carefully before using this product ...

Page 2: ...a then it will start measuring the kilowatts used over a measured period of time For instance you get a total use of Electricity Consumption kWh over 24 hours for an appliance and you can just multiply it by your Cost per kWh the utility charges you on your bill then you will know the daily cost to operate Similar way to assess your electrical expenses by the Day Week Month or Year Note Some utili...

Page 3: ...the maximum rated current in most cases the true RMS current will be around 14A to avoid any unnecessary damage or accident 4 DO NOT use or store in high temperature damp inflammable and explosive places The performance of the instrument may be degraded by dampness 5 DO NOT allow children to operate this device keep children away from the monitor NOTE The monitor work with standard AC power an inf...

Page 4: ...ove 1 Device startup shutdown Plug the monitor directly into the power socket and connect to AC power to start the device disconnect the power supply to shut down 2 Backlight Setting Under the current A display Amp press hold SET for 2 seconds to enter backlight setting interface It will display LEd after entering the ...

Page 5: ...en the device is not operated by the keys within 10 seconds ON means the backlight is always on default factory setting 3 Measurement display 1E AMeasuring mode Under measuring mode one can quickly check electricity parameters The unit will start to accumulate KWH and powered duration time hour after power is applied A 2E A Voltage Press Volt Key for true RMS Voltage Volts display as shown in Figu...

Page 6: ... is 0 00 15 00A A 4E A Watts and VA The Watt VA Key is a toggle function key Press the Watt VA key once to display Watt meter as shown in Figure 4 then press key to display VA meter as shown in Figure 5 The LCD will display Watts Watt VA PF as the active power from 0 00 2400W where VA is the apparent power VA Vrms Arms ...

Page 7: ...ltage where PF is the Power Factor PF Watts Vrms Arms A 6E A Electricity Consumption Cumulative Time The KWH Hour OK is a toggle function key Press the KWH Hour key once to show the cumulative Electricity Consumption EC as shown in Figure 8 since power was applied to the unit Then press key to display the Cumulative Time CT as shown in Figure 9 since power was applied to the unit The measuring dis...

Page 8: ...to reset A 7E A Overload Indication Setting Press the Watt VA key once on the watt display interface press hold SET for 2 seconds it will display the overload setting value as shown in Figure 10 Press SET again the thousand digit on LCD will flicker press or to adjust value and press SET after completing thousand digit adjustment to set hundred digit and so on Press OK in the end to exit the setti...

Page 9: ...ge 0 20W Maximum electricity consumption EC 9 999 kWh Maximum cumulative time CT 9 999 hours Power factor 0 01 1 00 Backlight function 10s Auto off ON OFF can be set Accuracy standard Class 1 0 Resolution 0 01W 0 01A 0 1V Power dissipation 1 00W Working temperature 0 45 Storage temperature 20 60 Product dimension 95 47 40 mm Net Weight 85g Warranty 1 Year 1 x PN1500 Electricity Usage Monitor 1 x U...

Reviews: