background image

IP Intelligent Video Analysis Camera  

PONI-S100-IVA, PONI-P100-IVA) 

Installation  Manual 

(English) 

 
  

                                                                 

Ver. 1.0 (110905) 

 

 

 

 

 
 

 
 

PONICO KOREA CORPORATION 

PONICO CANADA ENTERPRISE CORPORATION 

 

 

 

Summary of Contents for PONI-P100-IVA

Page 1: ...IP Intelligent Video Analysis Camera PONI S100 IVA PONI P100 IVA Installation Manual English Ver 1 0 110905 PONICO KOREA CORPORATION PONICO CANADA ENTERPRISE CORPORATION ...

Page 2: ... be replicated without permission of PONICO We are not responsible for the product damages caused by not following the instru ctions indicated in the manual and use of power sources other than indicated For repair and or extending functions of the product please contact the sales age ncy for technical assistance from professional engineers For any other inquiries or questions about the product ple...

Page 3: ...ing redundant movement and emphasizing core movement 5 CAM Sabotage Detection of mischief blocking view intentional change of angle against the camera 6 Viewer NVR Viewer Recording Remote monitoring and recording up to 9 locations at the same time At the time of playback and recording there is a function to search only designated event and recording only the event is available from a full recorded...

Page 4: ...e time of playback and recording there is a function to search only designated event and recording only the event is available from a full recorded images Applications Managerial Control As number of people being counted it is possible to analyze sales amount or quant ity by actual customers number Seasonal differential will be predicted by use of actual data on shops or on date Detailed sales tre...

Page 5: ...erson and cleaning person working based on number of actual visited customers It is possible to use such counted data for future investment or building expansion It is possible to prevent invasion of customers to dangerous area by use of counted data 2 Product Descriptions 2 1 Product Configuration and Package Contents 2 1 1 Followings are contained in the package A PONI S100 IVA PONI P100 IVA Cam...

Page 6: ...ps Ethernet please use standard RJ 45 Connecter LED light blinks to yellow when RJ 45 Connecter is correctly connected POWER Connecter Power is supplied by the adapter contained 12V 2A BNC Connecter Analog video is outputted from the camera Live images can be seen by connecting to a monitor LAN Cable Connecter 10Mbps 100Mbps Ethernet DC POWER Connecter BNC Connecter Analog Video Output Inside of C...

Page 7: ...actory Reset Reset to factory setting reset by pressing the button approximately 3 seconds while power is on to factory setting ZOOM Control Control and set magnification of the camera by the adjustment bar FOCUS Control Control and set focus of the camera by the adjustment bar Factory Reset Button GPIO Connecter Focus Zoom Lens Control ...

Page 8: ...ng light is DC 5V 100mmA If using devices requiring higher voltage and or current please purchase and use separate Reley switch Alarm Output1 5V 100mm GPIO91 GND Alarm Output2 5V 100mm GPIO91 GND 3 Product Installation 3 1 Camera Installation 3 1 1 Installation Guide A Install the camera as shown below Please make sure the place is strong enough for installing a camera ...

Page 9: ...ndows 2000 Windows XP Windows Vista The initial IP address of the camera is 192 168 1 100 Set the IP address of a desktop or laptop as next 192 168 1 5 Sebnet Mask 255 255 255 0 2 Connect the Network LAN cable of the camera Connecting PC directly to the camera use CROSS OVER cable Connecting through HUB Router use DIRECT cable Horizontal Rotation 360 PAN 360 TILT 90 FOCUS ZOOM ...

Page 10: ...ra is 192 168 1 100 To change the IP address install the provided IP Finder Software to a PC Then press SCAN on the right of the following screen all the IP address of Cameras presently connected to Sebnet will be shown Figure 1 Figure 1 B Clicking IP address of the camera CONNECT and RESET Buttons will appear By pressing CONNECT button will be connected to Web Viewer browser of the camera Figure ...

Page 11: ...ting Net mask Gateway etc and press OK Figure 3 4 Connect to Web viewer To view the camera through connecting network internet there are two ways by Web Viewer or NVR Viewer This manual only describes viewing by connecting to Web Viewer The description for viewing by connecting to NVR Viewer is in the manual located in the CD provided with the product Please refer to it ...

Page 12: ...4 1 Log in A As typing the IP address of the camera 192 168 1 100 in the Address bar of Internet Explorer window and pressing enter following screen appears ...

Page 13: ...Enter Following screes appears From factory setting Initial ID admin Password 11111111 Changing ID and Password Camera Setup etc are described in the IP Camera Setup Manual located in the CD provided with the product Please refer to it ...

Page 14: ...System Main Processor 32 bit Embedded CPU System Memory 64MB NAND Flash 128MB DDR Video Audio Compression D1 704x480 MJPEG H264 CIF 352x240 MJPEG H264 Dual Stream Frame Rate Max 30 fps Bit Rate 28K 6M bps image Settings Compression level setting CBR VBR Audio Two way Full duplex ADPCM Network Protocol IPv4 TCP UDP RTSP RTCP HTTP SMTP FTP DHCP DNS ICMP ARP Web Browser Microsoft Internet Explorer 6 ...

Page 15: ...B Camera Diagram 4 3 System Scheme A PONI S100 IVA Location ...

Page 16: ...B PONI P100 IVA PRODUCTION PONICO KOREA CORPORATION ...

Reviews: