Pompa ad Ingranaggi - Serie MX
Gear Pump - MX Series
41
stop immediately the motor, wait until the inner magnet cover (which became hot as a result
of eddy currents) is cooled and restart the motor after troubleshooting.
5.4.3
Pump system requirements
In volumetric pumps, pressure is not related to flow rate and/or rotation speed; therefore,
avoid installing shut-off valves on the discharge pipe and, in any case, between the pump
and the stop valve a relief valve must always be installed.
5.4.4
Startup/shutdown frequency
Pumps which are expressly requested by the Customer to start frequently and repeatedly do
not show any problems for this kind of operation.
5.4.5
Operation and startup with closed valve
It is forbidden to start the pump with the discharge valve closed
: such mistake would
cause an abrupt pressure rise above the limit values with consequent seizing.
5.5
SHUTDOWN
5.5.1
Decommissioning
In case of decommissioning of the pump unit, it is necessary to disconnect the power supply
to make unexpected and accidental startups impossible.
5.5.2
Emptying
A pump or a pump unit which operates with a flammable, toxic, corrosive or, in any way,
hazardous fluid, or with a liquid at a temperature higher than 55°C, shall be equipped with a
device such as a connection pipe,
to be provided by the User
, to collect and dispose the
liquid drained or coming from any possible leakage from the shaft seal or discharged by a
pressure relief valve.
6.
MAINTENANCE AND INSPECTION
Maintenance operations and pump disassembly must be performed only by author-
ized and specifically trained people.
6.1
USE PRECAUTIONS
Before performing any maintenance operation, please observe the following safety precau-
tions:
-
Never
execute maintenance operations with the pump running.
-
Cut the power supply to the pump unit.
-
Wear gloves, glasses, shoes and protective suits adequate to the characteristics of the
liquid being pumped.
-
Wait until the pump is cooled.
-
Never
open the pump unit and/or the relief valve when the pump is pressurized.
-
Close suction and discharge pipe valves, if any.
-
Disconnect the pump from suction and discharge pipes, by paying attention to put a col-
lecting basin for the pipe liquid.
-
In case externally flowed mechanical seals are used, disconnect the relevant pipes.
-
Cut the power supply to the motor and disconnect the earth cable.
-
Unscrew anchoring screws and remove the pump unit complete with its baseplate.
-
Disassemble the protection coupling guard and disconnect the pump from the motor.